Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR EXTERIOR 2 STORY PARTIALLY OPEN WOOD PORCH - COLUMNS RESTING ON CONCRETE BLOCKS, AND CONCRETE SLAB, WITH NO BASES. FOUNDATION STATUS UNKNOWN. STRINGERS INADEQUATELY SUPPORTED AT TOPS AND BOTTOMS WITH SCAB BLOCKS AND FASTENED WITH NAILS ONLY. 2X8 DECK JOISTS OVERSPAN. LEDGER BOARD AT ROOF FASTENED WITH NAILS ONLY. RAILING SECTIONS UNDERSIZED AT 24" - 28" HEIGHT. GUARDRAILS UNDERSIZED AT 36" WITH LADDER TYPE DESIGN SPACINGS UP TO 9" TO 12". TREADS WORN AND WEAK. DECKING WORN, AND WEAK. RISER HEIGHTS NOT UNIFORMED. 1ST THRU 2ND MIDLANDING EXCESSIVE SWAY. PLANS AND PERMIT REQUIRED TO REPAIR REAR EXTERIOR 2 STORY PARTIALLY OPEN WOOD PORCH WITH ROOF. | 2549 W SUMMERDALE AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING /NO RESPONSE. UNABLE TO VERIFY DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO INSPECT REAR 1ST FLOOR ENCLOSED PORCH. | 2549 W SUMMERDALE AVE | COMPLAINT | PASSED | View |