The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLACE D&H PORCH | REAR PORCH-DANGEROUS AND HAZARDOUS POSTED-WOOD ROTTED THRU-OUT, K4X4 COLUMNS RESTING ON CONCRETE SLAB - FOUNDATION STATUS UNKNOWN, 6X6 COLUMNS OVER NOTCHED, STRINGERS SKABBED, OVER CUT AND INADEQUATELY SUPPORTED AT BUILDING AND WOOD COLUMNS, STAIR RISERS OVER 10 INCHES FROM GRADE TO 1ST FLOOR. STAIR TREADS MISSING THUR-OUT. 2X10 BEAMS ROTTED, MISSING JOIST HANGER, TAILING TOO LOW AND LOOSE, DECKING ROTTED-PLANS AND PERMITS REQUIRED. | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
REPAIR LINTELS | WEST ELEVATION-LINTELS SAGGING AND RUSTED ALL FLOORS | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | WEST ELEVATION-WINDOW SILLS FRACTURED AND WASHED OUT MORTAR. | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION-WASHED OUT MORTAR-NORTH ELEVATION AT REAR SPALLING BRICK AND WASHED OUT MORTAR. | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
CHIMNEY | SOUTH ELEVATION-CHIMNEY-WASHED OUT MORTAR. | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | REAR YARD-WEEDS | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
REPAIR / REBUILD SHED | GARAGE-NORTH AND SOUTH WALLS AND PARAPET-LEANING EAST ELEVATION MISSING BRICKS, WEST ELEVATION-SPALLING BRICK AND WASHED OUT MORTAR. OVERHEAD DOOR BROKEN. | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
NOTIFY DOB, USE OF VACANT LND | (SR#800657349)-BUILDING VACANT AND SECURED | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View | |
PERMIT REQUIRED - CONTRACTOR | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View | |
PLANS & PERMITS REQ - CONTRCTR | PERMITS REQUIRED FOR (4) FORCED AIR FURNACE AND DUCTWORK | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS/PERMITS REQUIRED FOR 1ST FLOOR ADDITIONAL (SECOND) BATHROOM WITH JET TUB INSTALLED IN FIRST FLOOR DINING ROOM | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS REQUIRED ON ALL FLOORS TO INSTALL WALLS AND DOORS FROM HALL TO LIVING ROOM TO CREATE ADDITIONAL BEDROOMS | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
NO KEY TO USE EXIT DOOR | REMOVE ALL DEADBOLS AND KEYLOCKS FROM ALL BEDROOM DOORS ON ALL FLOORS(FIRE/SAFETY HAZARD) THREE APARTMENTS USED AS ROOMING HOUSE | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
OVERCROWDING | (3) APARTMENTS USED AS ROOMING HOUSE ( FIRE/SAFETY HAZARD ) | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRICAL )INSTALL IN BASEMENT WITHOUT PERMITS ( ADDITIONAL UNIT) | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND RESTORE THE BUILDING TO THE ORIGINAL STATE | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | NORTH AND SOUTH WINDOW FRAMES ROTTED FLAKING | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW SASH | NORTH AND SOUTH WINDOWS ROTTED FLAKING SASHES | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT REQUIRED FOR COMMERCIAL WATER HEATER INSTALLED IN BASEMENT | 6431 N HAMILTON AVE | COMPLAINT | PASSED | View |