Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
REPAIR DOOR, INT. INTERIOR OF PROPERTY BEDROOM AND BATHROOM DOORS MISSING HARDWARE, SPECIFICALLY DOOR HANDLES. 11217 S EGGLESTON AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIR SYSTEM FROM BASEMENT TO 1ST FLOOR LEVEL NOT STABLE AND MISSING COMPONENTS. (A) NO POSTS TO CARRY LIVE LOADS. (B) RAILS LOOSE AND PULLING. (C) TREADS FLEXING UNDER LIVE LOAD. (D) STRINGERS NAILED TO LANDING MISSING BRACES. (E) ALL CONNECTIONS NAILED ONLY, NO BRACES. 11217 S EGGLESTON AVE COMPLAINT FAILED View
SUBMIT STRUCT. ENG. RPT (INT.) 3 TEMPORARY STEEL SCREW JACK LIKE COLUMNS IN BASEMENT AREA SUPPORTING 1ST FLOOR STRUCTURALLY, TEMPORARY POSTS ARE SUBSTANDARD AND DOES NOT MEET TODAY'S CODE REQUIREMENT, STRUCTURAL ENGINEER'S REPORT IS REQUIRED TO DETERMINE IF TEMPORARY STRUCTURAL REPAIRS ARE SUFFICIENT. 11217 S EGGLESTON AVE COMPLAINT FAILED View
STRUCTURAL MEMBER, PIER BLOCK OBTAIN STRUCTURAL ENGINEER'S REPORT FOR PRIOR TEMP. STRUCTURE WORK DONE IN BASEMENT AREA. 11217 S EGGLESTON AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS NO WORKING SMOKE DETECTORS ON 1ST FLOOR LEVEL. DANGEROUS AND HAZARDOUS. 11217 S EGGLESTON AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE UNAPPROVED FLEXIBLE WATER SUPPLY PIPING TO 1ST FLOOR KITCHEN SINK, BATHROOM LAVATORY AND TOILET. 11217 S EGGLESTON AVE COMPLAINT FAILED View
INSECTS TENANT COMPLAINS OF BITING BUGS THROUGHOUT PROPERTY. INSPECTOR NOTICED BUGS IN KITCHEN AREA AT TIME OF INSPECTION. EXTERMINATOR REQUIRED. 11217 S EGGLESTON AVE COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL UNAPPROVED CORRUGATED PVC TUBULAR AT 1ST FLOOR KITCHEN SINK, UNAPPROVED RUBBER COUPLING AT BASEMENT LAUNDRY TUB. 11217 S EGGLESTON AVE COMPLAINT FAILED View
REPLACE DEFECTIVE TOILET SEAT BROKEN DEFECTIVE TOILET SEAT AT 1ST FLOOR BATHROOM TOILET. 11217 S EGGLESTON AVE COMPLAINT FAILED View
INDIRECT CONN.FOR WATER SUPPLY NO BACKFLOW PREVENTER TO BOILER AT BASEMENT ELEVATION. 11217 S EGGLESTON AVE COMPLAINT FAILED View
OBTAIN PERMIT FOR PLUMBING OBTAIN PERMIT BEFORE CONSTRUCTING. ALTERING, OR USING PLUMBING SYSTEM. 11217 S EGGLESTON AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING. 11217 S EGGLESTON AVE COMPLAINT FAILED View
INSTALL ILLUMINATION LIGHT MISSING FROM ENTRY DOORS. 11217 S EGGLESTON AVE COMPLAINT FAILED View
INSTALL GFCI'S MISSING GFCI RECEPTACLES ON KITCHEN COUNTERTOP AREAS. 11217 S EGGLESTON AVE COMPLAINT FAILED View
LISTED FOR USE TEMP & LOCATION EXCESSIVE USE OF ARMORED CABLE IN THE BASEMENT AREA. 11217 S EGGLESTON AVE COMPLAINT FAILED View
BOND AROUND FITTINGS MISSING COLD WATER GROUND. 11217 S EGGLESTON AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT OF PROPERTY WEST ELEVATION GUARD RAILS NOT ATTACHED TO PROPERTY, LOOSE AT LANDING AREA. 11217 S EGGLESTON AVE COMPLAINT FAILED View
SUPPLEMENTAL GROUND MISSING SUPPLEMENTAL GROUND. 11217 S EGGLESTON AVE COMPLAINT FAILED View