The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | ALL ELEVATIONS/ EXTERIOR WALLS- FRACTURED MASONRY, SPALLING BRICKS, WITH WASHED OUT MORTAR. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
CHIMNEY | NORTH, AND SOUTH ELEVATIONS/ CHIMNEYS- SPALLING BRICKS, WITH WASHED OUT MORTAR. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | NORTH, AND SOUTH ELEVATIONS- CHIMNEY CAPS MISSING. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | EAST ELEVATION/ LINTELS- RUSTING, PEELING PAINT, AND SAGGING. PERMIT REQUIRED TO REPLACE LINTELS. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR, AND SIDE EXTERIOR PORCHES/ COLUMNS ERECTED ON CONCRETE BLOCKS- FOUNDATION STATUS UNKNOWN. COLUMNS- LEANING, AND OUT OF PLUMB. ALL BEAMS, AND STRINGERS FASTENED TO COLUUMNS WITH NAILS ONLY. BEAMS, AND STRINGERS,- ROTTING, BROKEN , AND SCABBED. 2ND FLOOR CONCRETE DECK SUPPORTED BY TWO DIAGONAL STEEL ANGLE SUPPORTS ONLY. SOUTH ELEVATION STAIRWAY AT 2ND FLOOR DECREASES FROM 36 INCHES TO ONLY 18 INCHES WIDE FOR DISTANCE OF 4 FEET. PLANS, AND PERMIT REQUIRED TO REPLACE REAR, AND SIDE EXTERIOR PORCHES. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS, AND FIXTURES [INCLUDING PLUMBING, AND ELECTRIC] INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS, AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT, OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THROUGH 2011. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION- EXTERIOR WALL , VERTICAL FRACTURES 1ST AND 2ND FLOOR, NEAR WINDOWS | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
PARAPET & COPING | NORTH PARAPET- COPING TILE MISSING, AND PARAPET WALL SPALLING AND SHIFTING BRICKS. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY CAP- MISSING. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | EAST ELEVATION- LINTELS RUSTED AND SAGGING. BASEMENT , 1ST AND 2ND FLOOR. PERMIT REQUIRED FOR LINTEL REPLACEMENT. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH- COLUMNS ERECTED ON CRUMBLING CONCRETE 4 INCH FOUNDATION BASES. 4X4 COLUMNS BOWED. DECK BOARDS ON 1ST FLOOR DAMAGED. STAIR OPENING ONLY 24 INCHES WIDE.1ST FLOOR RAILING SYSTEM MISSING PICKETS. GUARD RAILING ONLY 32 INCHES IN HEIGHT AND STAIRWAY RAILING ONLY 24 INCHES IN HEIGHT.2ND FLOOR CONCRETE LANDING SUPPORTED WITH ONLY ONE METAL BRACE.PLANS AND PERMIT REQUIRED TO REPAIR PORCH. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | APT 2REAR- EXTERIOR DOOR PEELING VENEER. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | REAR ENCLOSED PORCH -2ND FLOOR , NO ILLUMINATION. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE , UNVERIFIED DETECTORS AND OCCUPANCY.SOUTH YARD- NO ENTRY, UNABLE TO INSPECT PORCH. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR - NEW 2 STORY ENCLOSURE BUILT, NO PLANS SUBMITTED AND NO PERMIT OBTAINED . | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | APT 2REAR- EXTERIOR DOOR PEELING VENEER. | 6632 S FRANCISCO AVE | COMPLAINT | CLOSED | View |
ILLUMINATE PUBLIC STAIR/HALL | REAR ENCLOSED PORCH -2ND FLOOR , NO ILLUMINATION. | 6632 S FRANCISCO AVE | COMPLAINT | CLOSED | View |
ROACHES | APT 2 REAR- ROACHES CRAWLING AT TIME OF INSPECTION. | 6632 S FRANCISCO AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE , UNVERIFIED DETECTORS AND OCCUPANCY.SOUTH YARD- NO ENTRY, UNABLE TO INSPECT PORCH. | 6632 S FRANCISCO AVE | COMPLAINT | CLOSED | View |
PARAPET | ALL ELEVATIONS/ PARAPET WALLS- FRACTURED MASONRY, SPALLING BRICKS, WITH WASHED OUT MORTAR. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY, AND REAR ENCLOSED PORCH- MISSING SMOKE DETECTORS. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING/ OWNERS ID SIGN- MISSING. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY - MISSING MORTAR. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |
ROACHES | APT 2 REAR- ROACHES CRAWLING AT TIME OF INSPECTION. | 6632 S FRANCISCO AVE | COMPLAINT | FAILED | View |