Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 7:47 PM
PIN: 20342090310000
Property Address: 8048 S EBERHART AVE
City - Zip: CHICAGO - 60619
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70120
2023 Tax District: 70001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 5 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM COLUMNS OUT OF LEVEL,BEAMS AND COLUMNS SCABBED,1ST AND 2ND LEVELS SEVERLY OUT OF LEVEL,DECKING ROTTED 1ST FLOOR,GUARDRAILS UNDER 42IN TALL,STRINGERS NOT BOLTED TREADS LOOSE AND DAMAGED,UNEQUAL RISER HEIGHTS,JOIST SCABBED AND ROTTED, NOVISIBLE FOUNDATION PLITH BLOCKS 8048 S EBERHART AVE COMPLAINT FAILED View
PARAPET PARAPET LOOSE BRICK REAR ALSO SOUTH 8048 S EBERHART AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PLANS AND PERMITS FOR REPAIR/REPLACEMENT OF REAR PORCH(PROTOTYPE PLANS MAY BE AVAIVABLE ON CITYS WEB SITE) 8048 S EBERHART AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING /OWNER¿S I.D. SIGN ¿ MISSING. 8048 S EBERHART AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR 2 STORY WOOD PORCH, WITH ROOF.-FOUNDATIONS /BASES FORMED BY CONCRETE POURED IN AROUND COLUMN, FOUNDATION STATUS UNKNOWN.-COLUMNS /INADEQUATE HALF-LAP JOINTS WITH OVERLAP OF ONLY 6 INCHES, WITH ONLY 2 BOLT USED OF 1/2 INCHES IN DIAMETER. -COLUMNS /OVER NOTCHED WITH FIRE CUTS KNOTCHED UP TO 3 1/2 INCHES INTO 6X6 COLUMNS.-STRINGERS /UPPER AND LOWER ENDS OF STRINGERS, FASTENED WITH NAILS OR SCREWS ONLY. PITCHED DOWN-WARD. UPPER ENDS - OVER CUT.-STAIRS /RISER HEIGHT NOT UNIFORMED, RANGING FROM 3 1/2 INCHES TO 9 3/4 INCHES TO 7 1/2 INCHES TO 8 3/4 INCHES. TREADS ONLY UPTO 9 1/2 INCES, WITH UNEVEN NOSING RANGING FROM 3/4 INCHES UP TO 1 1/4 INCHES.-RAILING SECTIONS /GRADE TO BASEMENT - MISSING. ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS OR SCREWS ONLY.PLANS AND PERMIT REQUIRED TO REPLACE. 8048 S EBERHART AVE COMPLAINT PASSED View