Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
STOP SMOKE, NOXIOUS ODORS | REAR PORCH/ 2ND AND 3RD FLOORS - NOXIOUS ODORS FROM ANIMALS FOULING. | 1652 N TALMAN AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR 3-STORY WOOD PORCH - 6X6 COLUMNS RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. UNDERSIZED 2X6 DECK JOISTS SPAN 10'. 6X6 COLUMNS OVERNOTCHED WITH CUTS MADE IN ERROR. 6X6 BEAMS PULLING OUT OF FIRE CUTS. 6X6 COLUMNS OVER NOTCHED AT BEAM CONNECTION. STRINGERS ONLY NAILED TO MASONRY WALL. RAILINGS ONLY 38" HIGH, LOOSE AND PULLING. TREADS AND DECK BOARDS WORN AND ROTTED. RISER HEIGHTS NOT UNIFORM. PORCH MEMBERS ONLY SCREWED AND NAILED TOGETHER. PLANS AND PERMIT REQUIRED TO REPLACE REAR 3-STORY PORCH. | 1652 N TALMAN AVE | COMPLAINT | PASSED | View |
CUT OR REMOVE HIGH WEEDS | REAR YARD - HIGH WEEDS AND GRASS. | 1652 N TALMAN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | REAR ELEVATION/ STAIRWAY FROM BASEMENT TO GRADE - MISSING HANDRAIL. | 1652 N TALMAN AVE | COMPLAINT | PASSED | View |
REPAIR CORNICE | SOUTH ELEVATION/ CORNICE - MISSING | 1652 N TALMAN AVE | COMPLAINT | PASSED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR PORCH/ 2ND TO 3RD FLOOR LANDING - PILE OF ANIMAL EXCREMENTS, UNSANITARY AND OFFENSIVE CONDITION. | 1652 N TALMAN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | REAR ELEVATION/ VINYL SIDING - LOOSE WITH MISSING SECTIONS. NORTH ELEVATION/ ASPHALT SIDING - LOOSE WITH HOLES AND MISSING SECTIONS. | 1652 N TALMAN AVE | COMPLAINT | PASSED | View |
PIGEONS-UNSANITARY HOUSING | REAR PORCH/ 2ND AND 3RD FLOORS - FOULING OF PREMISES CAUSED BY ROOSTING AND NESTING PIGEONS. | 1652 N TALMAN AVE | COMPLAINT | PASSED | View |
DEMO DEBRIS | REAR YARD - LARGE PILE OF USED LUMBER ON THE GROUND. | 1652 N TALMAN AVE | COMPLAINT | PASSED | View |
EXPOSED WIRING | OPEN JUNCTION BOXES AT REAR PORCH. LIVE WIRING EXPOSED DANGEROUS AND HAZARDOUS | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | METER ENCLOSURE DAMAGED. REPLACE AS REQUIRED | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | DEFECTIVE LIGHT FIXTURES AT REAR PORCH. FIXTURES HANGING NEED PROPER SUPPORT | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
SERVICE CONDUCTORS SUPPLYING THE BUILDING NEXT DOOR (1654 N TALMAN) HAVE THEIR ATTACHMENT POINT ON THE BACK OF 1652 N TALMAN. SERVICE CONDUCTORS SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY MAENS OF APPROVED RACEWAY. SERVICE CONDUCTORS HAVE BEEN RUN "FREE AIR" AND ARE RUBBING ON CORNER OF BUILDING. (14E-2-230.50) DANGEROUS AND HAZARDOUS. | 1652 N TALMAN AVE | COMPLAINT | FAILED | View | |
DEFECTIVE SERVICE | ELECTRICAL PANELS ARE NOTRATED FOR EXTERIOR USE AND SHOWING SIGNS OF MAJOR CORROSION AND DETERIORATION. ELECTRICAL PANELS HAVE LIVE OPEN BUSBARS. REPLACEMENT OF PANELS IS REQUIRED. DANGEROUS AND HAZARDOUS | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | NO ELECTRICAL METALLIC TUBING FOR SERVICE ENTRANCE CONDUITS PERMITTED (14E-2-230.50) | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | SOUTH ELEVATION/ CORNICE - MISSING | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REAR ELEVATION/ VINYL SIDING - LOOSE WITH MISSING SECTIONS. NORTH ELEVATION/ ASPHALT SIDING - LOOSE WITH HOLES AND MISSING SECTIONS. | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | REAR YARD - LARGE PILE OF USED LUMBER ON THE GROUND. | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | REAR YARD - HIGH WEEDS AND GRASS. | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
PIGEONS-UNSANITARY HOUSING | REAR PORCH/ 2ND AND 3RD FLOORS - FOULING OF PREMISES CAUSED BY ROOSTING AND NESTING PIGEONS. | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | REAR PORCH/ 2ND AND 3RD FLOORS - NOXIOUS ODORS FROM ANIMALS FOULING. | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR ELEVATION/ STAIRWAY FROM BASEMENT TO GRADE - MISSING HANDRAIL. | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 3-STORY WOOD PORCH - 6X6 COLUMNS RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. UNDERSIZED 2X6 DECK JOISTS SPAN 10'. 6X6 COLUMNS OVERNOTCHED WITH CUTS MADE IN ERROR. 6X6 BEAMS PULLING OUT OF FIRE CUTS. 6X6 COLUMNS OVER NOTCHED AT BEAM CONNECTION. STRINGERS ONLY NAILED TO MASONRY WALL. RAILINGS ONLY 38" HIGH, LOOSE AND PULLING. TREADS AND DECK BOARDS WORN AND ROTTED. RISER HEIGHTS NOT UNIFORM. PORCH MEMBERS ONLY SCREWED AND NAILED TOGETHER. PLANS AND PERMIT REQUIRED TO REPLACE REAR 3-STORY PORCH. | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR PORCH/ 2ND TO 3RD FLOOR LANDING - PILE OF ANIMAL EXCREMENTS, UNSANITARY AND OFFENSIVE CONDITION. | 1652 N TALMAN AVE | COMPLAINT | FAILED | View |