Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN NOT POSTED | 4048 W NELSON ST | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | REAR FRONT INTERIOR STAIR TO BASEMENT MISSING HANDRAIL | 4048 W NELSON ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | ERECTED 2 CAR GARAGE WITH CAR PORT DRIVEWAY WITHOUT PLANS AND PERMIT | 4048 W NELSON ST | COMPLAINT | PASSED | View |
CONTRARY TO ORIGINAL PLAN | BASEMENT STORAGE SPACE HAS BEEN CONVERTED INTO A FAMILY UNIT. | 4048 W NELSON ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT - SUBMIT PLANS AND PERMIT FOR DECONVERSION | 4048 W NELSON ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | BASEMENT - RESTORE SPACE TO ITS ORIGINAL CONFIGURATION | 4048 W NELSON ST | COMPLAINT | PASSED | View |
STAIRWELL ENCLOSURE - BASEMENT | BASEMENT - STAIRWELL DOES NOT PROVIDE A 1-HR FIRE RATING | 4048 W NELSON ST | COMPLAINT | PASSED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT - PROVIDE A FIRE SEPARATION FOR DWELLING UNIT | 4048 W NELSON ST | COMPLAINT | PASSED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | REMOVE ALL PLUMBING ILLEGALLY AND IMPROPERLY INSTALLED WITHOUT PERMIT INCLUDING PLUMBING FIXTURES AND RELATED PIPING ABOVE AND BELOW GRADE AT BASEMENT UNIT. | 4048 W NELSON ST | COMPLAINT | PASSED | View |
CONNECT DOWNSPOUT TO SEWER | CONNECT DOWNSPOUT TO SEWER IN REAR YARD | 4048 W NELSON ST | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | A LICENSED AND BONDED PLUMBING CONTRACTOR IS REQUIRED | 4048 W NELSON ST | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | INSTALL GFCI RECEPTACLES IN ALL REQUIRED LOCATIONS - LAUNDRY AREA IN BASEMENT AND BASEMENT BATHROOM (18-27-570.8) | 4048 W NELSON ST | COMPLAINT | PASSED | View |
REMOVE EXPOSED CABLE | REMOVE NON-METALLIC CABLE (ROMEX) FOR LIGHT FIXTURE AND SWITCH IN REAR BEDROOM OF BASEMENT (UNAPPROVED) | 4048 W NELSON ST | COMPLAINT | PASSED | View |
WORKING SPACE | PROVIDE ADEQUATE CLEARANCE (3 FT.) IN FRONT OF ELECTRICAL PANEL IN REAR BEDROOM OF BASEMENT | 4048 W NELSON ST | COMPLAINT | PASSED | View |
GROUND DOORBELL TRANS | PROPERLY GROUND DOORBELL TRANSFORMER IN HALLWAY ABOVE DOORWAY TO BOILER ROOM IN BASEMENT | 4048 W NELSON ST | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR CONDUIT ON BRICK WALL OF NORTH EXTERIOR (CONDUIT SEPARATED FROM ELBOW ENTERING BRICK WALL (WIRES EXPOSED) | 4048 W NELSON ST | COMPLAINT | PASSED | View |
BOX FOR BX SPLICE | INSTALL JUNCTION BOXES FOR OPEN SPLICES IN ARMORED CABLE ABOVE REAR DOORWAYS INSIDE REAR PORCH | 4048 W NELSON ST | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | PERMIT REQUIRED TO CORRECT ALL ELECTRICAL VIOLATIONS (13-12-360) | 4048 W NELSON ST | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE PVC UNDERGROUND IN REAR BACKYARD DRAINAGE | 4048 W NELSON ST | COMPLAINT | PASSED | View |
SUBMIT PLANS FOR PLUMBING PRMT | PROVIDE PLANS AND PERMITS FOR BASEMENT DECONVERSION | 4048 W NELSON ST | COMPLAINT | PASSED | View |