Chicago Building Violations Data: 32 Violations
Violation Inspector Comments Address Category Status View
POST APPROVED OCCUPANCY CARD OBTAIN AND POST OCCUPANCY CARDS FOR 2 WOMEN'S WORK OUT ROOMS, ALSO POST OCCUPANCY DIAGRAMS 3003 W TOUHY AVE PERIODIC FAILED View
POST APPROVED OCCUPANCY CARD OBTAIN AND POST OCCUPANCY CARDS WITH DIAGRAMS FOR 2 NEW WOMEN'S WORKOUT ROOMS 3003 W TOUHY AVE PERIODIC PASSED View
STOP WORK FOR PERMIT STOP HVAC WORK UNTIL PERMIT IS OBTAIN 13-32-110 3003 W TOUHY AVE COMPLAINT FAILED View
SUBMIT PLANS/GET VENT PERMIT OBTAIN PERMIT WITH PLANS FOR FIVE NEW R.T.U.SYSTEMS THAT REPLACED ONE LARGER UNITS,13-32-020,13-32-130,13-40-010, 18-28-403.14,13-40-140,13-32-270 3003 W TOUHY AVE COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. ARRANGE INSPECTION AFTER PERMIT/PLAN IS OBTAINED 13-12-100,13-20-290,13-32-270 3003 W TOUHY AVE COMPLAINT PASSED View
ARRANGE LICENSE INSP. ARRANGE DAYCARE LICENSE INSPECTION AFTER WORK AND VIOLATIONS ARE CORRECTED 13-12-100 3003 W TOUHY AVE COMPLAINT PASSED View
INSTALL VENT/AS SHOWN ON PLANS HVAC WORK AND FRAMING OF IRON SUPPORT MUST BE INSTALLED AS PER STAMPED PLAN 13-40-100 18-28-403.3 3003 W TOUHY AVE COMPLAINT PASSED View
POST APPROVED OCCUPANCY CARD POST OCCUPANCY CARDS AND DIAGRAMS FOR WOMENS WORKOUT ROOMS 1 AND 2 3003 W TOUHY AVE PERIODIC FAILED View
SEE INSPECTOR COMMENTS 3003 W TOUHY AVE PERMIT FAILED View
PRV HIGH SIDE 450 PSIG FOR: FOUR MCQUAY 7-1/2 TON (2 CABINETS) SELF-CONTAINED TWO MCQUAY 4 TON (1 CABINET) SELF-CONTAINED TWO MCQUAY 7-1/2 TON SELF-CONTAINED ONE CARRIER 25 TON SELF-CONTAINED A/C UNIT ALL LOCATED ON ROOF. 3003 W TOUHY AVE PERIODIC PASSED View
AMMONIA VENT LINE FOR TWO AIRSTACK SELF-CONTAINED 80 TON A/C UNIT LOCATED IN BASEMENT MECH ROOM. 3003 W TOUHY AVE PERIODIC PASSED View
POST APPROVED OCCUPANCY CARD POST OCCUPANCY CARDS WITH DIAGRAMS FOR GYM AND WOMENS WORKOUT ROOMS 1 AND 2 COMBINED 3003 W TOUHY AVE PERIODIC PASSED View
REPAIR LINTELS SOUTH ELEVATION AT WEST END OF BUILDING -GLASS BLOCK WINDOW WALL IRON LINTELS RUSTED AND DETERIORATED . 3003 W TOUHY AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS SOUTH ELEVATION AT WEST END OF BUILDING - LARGE GLASS BLOCK WALL METAL WINDOW SILLS RUSTED , DETERIORATED WITH GAP IN CAULKING , NOT SEALED TO GLASS . 3003 W TOUHY AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION SOUTH ELEVATION AT WEST END OF BUILDING -BELOW GLASS BLOCK WALL , SPALLED CONCRETE ,LOOSE WITH EXPOSED AND RUSTED REBARS . 3003 W TOUHY AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR EAST CENTER CONCRETE STAIRS , BROKEN CONCRETE TREADS . GUARDRAILS RUSTED WITH FLAKING PAINT . MISSING ALL PICKETS AND ONLY 36 INCHES HIGH . NORTH SIDE OF LANDING , FRACTURED AND MOVED OUT CONCRETE . 3003 W TOUHY AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM SOUTH ELEVATION AT EAST END OF BUILDING - IRON STAIRS AND LANDING . STAIR SYSTEM SAGGING AND LEANING OUT WITH FOUNDATION FAILURE . IRON UPRIGHT LEANING . LANDING AND STAIRWAY LEANING . GUARDRAILS MISSING ALL PICKETS AND ONLY 36 INCHES HIGH . METAL TREADS BENT AND SAGGING WITH ALL RISERS MISSING . PERMIT REQUIRED FOR REPAIRS . 3003 W TOUHY AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH ELEVATION AT WEST END OF BUILDING -LARGE GLASS BLOCK WALL WITH NUMERIOUS BLOCK BROKEN , CRACKED AND FRACTURED . HAZARD TO OCCUPANTS AND PASSERBYS. 3003 W TOUHY AVE COMPLAINT FAILED View
REPAIR / REBUILD SHED SOUTH ELEVATION AT WEST END OF BUILDING - WOOD FRAME YARD SHED ROTTED AND DILAPIDATED . SLAB FOUNDATION SAGGING , BUILDING LEANING . SIDING AND TRIM ROTTED WITH FLAKING PAINT . 3003 W TOUHY AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH SOUTH ELEVATION AT WEST END OF BUILDING - LARGE GLASS BLOCK WALL , IRON FRAME RUSTED , DETERIORATED WITH FLAKING FINISH . 3003 W TOUHY AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FITTINGS SOUTH ELEVATION AT WEST END OF BUILDING - HOSE VALVE AND SPICKETS LEAKING AND CAUSING FLOODING IN LANDSCAPED AREA . 3003 W TOUHY AVE COMPLAINT FAILED View
PRV HIGH SIDE 450 PSIG FOR: FOUR MCQUAY 7-1/2 TON (2 CABINETS) SELF-CONTAINED TWO MCQUAY 4 TON (1 CABINET) SELF-CONTAINED TWO MCQUAY 7-1/2 TON SELF-CONTAINED ONE CARRIER 25 TON SELF-CONTAINED A/C UNIT ALL LOCATED ON ROOF. 3003 W TOUHY AVE PERIODIC FAILED View
AMMONIA VENT LINE FOR TWO AIRSTACK SELF-CONTAINED 80 TON A/C UNIT LOCATED IN BASEMENT MECH ROOM. 3003 W TOUHY AVE PERIODIC FAILED View
ARRANGE PERMIT INSP. 3003 W TOUHY AVE PERMIT PASSED View
SUBMIT PLANS/GET VENT PERMIT OBTAIN REPLACEMENT PERMIT FOR 5 CARRIER ROOF TOP UNITS INSTALLED TO DAYCARE ROOMS 3003 W TOUHY AVE COMPLAINT PASSED View
GIVE VENT OPENINGS % FL. AREA PROVIDE POWER EXHAUST EQUIPMENT TO 5 R.T.U.'S THAT WERE INSTALLED WITHOUT PERMIT 3003 W TOUHY AVE COMPLAINT PASSED View
OUTSIDE AIR 15FT SEPERATE OUTSIDE AIR INTAKES FROM EXHAUST ON THREE CARRIER ROOF TOP UNITS INSTALLED UNDER PERMIT # 100513807 3003 W TOUHY AVE COMPLAINT PASSED View
ARRANGE LICENSE INSP. ARRANGE INSPECTION AFTER VIOLATIONS ARE CORRECTED 3003 W TOUHY AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR PROVIDE STRUCTURAL REPORT FOR ROOF SUPPORTING RTUS 3003 W TOUHY AVE PERMIT FAILED View
ARRANGE FOR RE-INSPECTION NO PRV`S 3003 W TOUHY AVE PERMIT PASSED View
POST APPROVED OCCUPANCY CARD 3003 W TOUHY AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE SOUTH ELEVATION AT CENTER OF BUILDING - INCOMING POWER SERVICE , BIRDS NESTING IN CABLES . 3003 W TOUHY AVE COMPLAINT FAILED View