Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR WOOD PORCHES: 6121-IMPROPER CONCRETE BLOCK FOUNDATIONS, 6X6 COLUMNS MISSING TIE POST BASE, LEDGERS MISSING BOLTS, JOISTS MISSING HANGERS, BEAM-COLUMN CONNECTIONS MISSING BOLTS AND STEEL ANGLES, 6X6 COLUMNS TOE-NAILED, COLUMN 1/2 LAP JOINTS, 2 BOLTS ONLY, GUARDRAILS NOT BOLTED TO MASONRY WALLS, GUARDRAILS AND HANDRAILS MISSING TIE ANGLE CONNECTORS, STRINGERS OVERCUT AND NOT BOLTED TO POSTS; 6123-FOUNDATIONS MISSING, COLUMNS RESTING ON GROUND AND MISSING TIE POST BASE, LEDGERS MISSING BOLTS, JOISTS MISSING HANGERS, BEAM-COLUMN CONNECTIONS MISSING BOLTS AND STEEL ANGLES, 6X6 COLUMN TOE-NAILED, COLUMN 1/2 LAP JOINTS-2 BOLTS ONLY, GUARDRAILS NOT BOLTED TO MASONRY WALLS, GUARDRAILS AND HANDRAILS MISSING TIE ANGLE CONNECTORS, STRINGERS OVERCUT AND NOT BOLTED TO POSTS; OBTAIN PLANS AND PERMIT | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR ROOF | 6121, REAR: ROOF HATCH OPEN | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
NO BARBED WIRE ON FENCE < 8FT | REAR FENCE: BARBED WIRE | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE, ALL ELEVATIONS: OPEN MORTAR JOINTS; SOUTH ELEVATION: MISSING MASONRY | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
NO BARBED WIRE ON FENCE < 8FT | REAR FENCE BARB WIRE. | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | REAR GARAGE AT ALLEY SIDE ROTTED SECTIONS WITH HOLES GRADE LEVEL. | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | WATER DAMAGEDE DRYWALL IN 6123 BASEMENT APARTMENT, REPLACED. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | WATER DAMAGED CARPETING IN 6123 BASEMENT APARTMENT REPLACED. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR DOOR FRAME, MULLION | FRAME WITH DOUBLE DOORS IS FALLING OFF AT BASEMENT BOILER ROOM. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR EXIT AT GRADE LEVEL USED FOR STORAGE AT 6123 | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR BALCONY | FRONT ELEVATION / MULTIPLE LOCATIONS / BALCONIES / CEILINGS - CRACKED AND SPALLING. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERS ID POSTED | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | 2 LARGE DEAD TREES IN BACKYARD HIGH WEEDS BY GARAGE. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | WATER DAMAGEDE DRYWALL IN 6123 BASEMENT APARTMENT, REPLACED. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | WATER DAMAGED CARPETING IN 6123 BASEMENT APARTMENT REPLACED. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR DOOR FRAME, MULLION | FRAME WITH DOUBLE DOORS IS FALLING OFF AT BASEMENT BOILER ROOM. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR EXIT AT GRADE LEVEL USED FOR STORAGE AT 6123 | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 2-3 STORY REAR WOOD PORCHES IMPROPER CONCRETE BLOCK, FOUNDATION 6X6 COULMNS MISSING TIE AT POST BASE, LEDGERS MISSING BOLTS, MISSING JOIST HANGERS, BEAM TO COLUMN CONNECTIONS ARE MISSING BOTLS, 6X6 COLUMNS ARE BUT JOINED NOT LAP CUT, | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERS ID POSTED | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 2-3 STORY REAR WOOD PORCHES IMPROPER CONCRETE BLOCK, FOUNDATION 6X6 COULMNS MISSING TIE AT POST BASE, LEDGERS MISSING BOLTS, MISSING JOIST HANGERS, BEAM TO COLUMN CONNECTIONS ARE MISSING BOTLS, 6X6 COLUMNS ARE BUT JOINED NOT LAP CUT, | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | FLOOR DRAIN AT 6121 NORTH BASEMENT APARTMENT, REAR DOOR. (11-16-020) (18-29-301.3) (13-168-120) | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | 1(4-332-010-100) (18-29-106.2) (13-168-070) | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | (11-16-020) (18-29-301.3) (13-168-120) | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCHES BUTT JOINED COLUMNS AT EACH LEVEL, NO STRIPS AT FIRECUTS, STAIR AND LANDING SYSTEMS SWAY SOUTH MORE SEVERELY BECAUSE OF LESS X BRACING, COLUMNS ON SIDEWALK SOUTH NO POSITIVE ATTADMENT TO NORTH COLUMNS, NO CLIPS AT JOISTS. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | STRINGERS NOT BOLTED, TREADS UNDERSIZED 4X4 HANDRAIL POSES NOT BOLTED WEAK. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
NO BARBED WIRE ON FENCE < 8FT | BARBED WIRE AT REAR FENCE 6"5" OFF THE GROUND. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE MAIN DOOR FRAME DAMAGED PARTIALLY OPEN, SOUTH GARAGE WALL TWO LARGE HOLES WHERE MORTAR HAS FAILED AND BRICKS HAVE FALLEN OUT. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT BEFORE PERFORMING ANY WORK. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | LOOSE MISSING MORTAR FRONT NORTH AT GRADE, WASHED OUT MORTAR REAR WALL GRADE TO 3./LOOSE MISSING MORTAR COLUMNS AT BALCONIES ALL AND 6121 NORTH 1ST FLOOR | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR BALCONY | BALCONY CEILING DETERIORATING 2ND FLOOR SOUTH CEILINGS | 6121 S MICHIGAN AVE | PERIODIC | CLOSED | View |
REPAIR PORCH SYSTEM | REAR PORCHES BUTT JOINED COLUMNS AT EACH LEVEL, NO STRIPS AT FIRECUTS, STAIR AND LANDING SYSTEMS SWAY SOUTH MORE SEVERELY BECAUSE OF LESS X BRACING, COLUMNS ON SIDEWALK SOUTH NO POSITIVE ATTADMENT TO NORTH COLUMNS, NO CLIPS AT JOISTS./REAR PORCHES SWAY NO ANCHOR BRACKETS AT COLUMNS SINGLE 2X8 BEAMS NOT BOLTED NO ANGLE IRON COLUMN BRACKETS AT BEAMS STRINGERS NOT BOLTED | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
NO BARBED WIRE ON FENCE < 8FT | BARBED WIRE AT REAR FENCE 6"5" OFF THE GROUND/BARBED WIRE BELOW 1 STORY AT NORTH GATE | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | NORTH, SOUTH AND WEST ELEVATIONS /METAL BALCONY LINTELS/"I" BEAMS - RUSTED, BENT, SAGGING, WITH GAPS ABOVE IT.PLANS AND PERMIT REQUIRED TO REPLACE.WEST ELEVATION /METAL WINDOW LINTELS - RUSTED, BENT, SAGGING, WITH GAPS ABOVE IT.PERMIT REQUIRED TO REPLACE. | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | TWO REAR 3-STORY WOOD PORCHES / MULTIPLE LOCATIONS / GUARDRAILS AND HANDRAILS - MISSING PICKETS. TREADS - CRACKED, WORN OUT AND WEAK. POSTS - CRACKED WITH ROTTING WOOD. PERMIT ONLY REQUIRED FOR REAR PORCHES' REPAIRS. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS / MULTIPLE LOCATIONS / WINDOW SCREENS - MISSING. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS / MULTIPLE LOCATIONS / WINDOW SCREENS - RIPPED. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | NOT REGISTERED 2006. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | LOOSE MISSING MORTAR FRONT NORTH AT GRADE, WASHED OUT MORTAR REAR WALL GRADE TO 3. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | BUSTED SILL 1ST FLOOR SOUTH. | 6121 S MICHIGAN AVE | PERIODIC | CLOSED | View |
REPAIR BALCONY | BALCONY CEILING DETERIORATING 2ND FLOOR SOUTH. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR DOOR, INT. | 6121 S. /BASEMENT APT. - REAR INTERIOR DOOR - TOO SMALL FOR FRAME, WITH GAPS AT BOTTOM AND JAMS.6121-23 S. /FRONT INTERIOR FOYER DOOR - OFF HINGES - NO POSITIVE LATCH. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION /EXTERIOR WALL - FRACTURED BRICK, WITH WASHED OUT MORTAR.PERMIT REQUIRED TO REPAIR. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY WOOD PORCHES, WITH ROOFS.-COLUMNS /STACKED UP ON TOP OF ONE ANOTHER, FASTENED WITH NAILS OR SCREWS ONLY AT BEAM CONNECTIONS.-RAILINGS /TOP RAIL SECTIONS - ROTTED, DETERIORATING AT SECTIONS - LOOSE AND PULLING. PICKET SECTIONS - MISSING.HARDWARE THROUHGOUT - RUSTED.REPAIR PERMIT REQUIRED TO REPAIR. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
MICE/RODENTS | BUILDING THROUGHOUT ¿ MICE, DROPPINGS OBSERVED IN 6121 S. /BASEMENT APT. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | 6121 S. /REAR BASEMENT LAUNDRY ROOM - WALLS AND CEILING - LARGE HOLES WITH SECTIONS MISSING - MILDEW. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR LINTELS | NORTH, SOUTH AND WEST ELEVATIONS /METAL BALCONY LINTELS/"I" BEAMS - RUSTED, BENT, SAGGING, WITH GAPS ABOVE IT.PLANS AND PERMIT REQUIRED TO REPLACE.WEST ELEVATION /METAL WINDOW LINTELS - RUSTED, BENT, SAGGING, WITH GAPS ABOVE IT.PERMIT REQUIRED TO REPLACE. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
FILE BLDG REGISTRATION | NOT REGISTERED 2006/REGISTER BUILDING FOR 2006 | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR BALCONY | BALCONIES WATER DAMAGE 1ST AND 2ND FLOORS 6121 CEILINGS | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS NEEDED FOR PORCHES PLANS MAY BE AVAILABLE AT WWW.CITYOFCHICAGO.ORG | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | LOOSE PLASTER EXPOSED CORNER BEEN UNPAINTED PLASTER BATHROOMS AND VARIOUS LOCATIONS IN APARTMENTS 6121 BASEMENT AND 6123 2ND FLOOR | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
STOP LEAKING WATER | LEAK AT 6121 1ST FLOOR BATHROOM | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
WINDOW OPEN EASILY, STAY OPEN | WINDOW 6123 2ND FLOOR BEDROOM WON'T STAY UP | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
MICE/RODENTS | BUILDING THROUGHOUT ¿ MICE, DROPPINGS OBSERVED IN 6121 S. /BASEMENT APT. | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 6121 S. /REAR BASEMENT LAUNDRY ROOM - WALLS AND CEILING - LARGE HOLES WITH SECTIONS MISSING - MILDEW. | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | 6121 S. /REAR BASEMENT LAUNDRY ROOM DRAIN AND REAR EXTERIOR DRAIN [GRADE TO BASEMENT] - CLOGGED WITH DEBRIS. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR GUTTER | 6121 S. /SOUTHEAST ROOF GUTTER - RUSTED WITH LARGE HOLES. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR FENCE | NORTH, SOUTH AND WEST ELEVATIONS /6 FEET METAL FENCE AND GATE ERECTED WITHOUT A PERMIT. SOUTH ELEVATION [AT WEST] /6 FEET METAL GATE SECTION - LOOSE AND HANGING.PERMIT REQUIRED. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR, RESET | 6121 S. /REAR EXTERIOR DOOR [GRADE TO BASEMENT] - TOO SMALL FOR FRAME, WITH GAPS AT BOTTOM AND JAMS. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR HARDWARE | 6121-23 S. /FRONT EXTERIOR DOOR - OFF HINGES - NO POSITIVE LATCH. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | 6121-23 S. /FRONT INTERIOR STAIRWELL - 1ST. LANDING - SPINDLES - LOOSE AND PULLING. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPLACE HOUSE DRAIN PIPING | WATER DISCHARGING INTO GROUND FLOOR, NORTH APARTMENT(11-16-020), (18-29-301.3), (13-168-120) | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | 1(4-332-010-100), (18-29-106.2), (13-168-070) | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY FOR ANNUAL INSPECTION | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH REPAIR - REPAIR NOT ACCORDING TO PLANS NEWEL POST NOT ON FOUNDATION, PLANS ASKED TO REMOVE 6X6 AND REPLACE WITH DOUBLE SUPPORT. NO DETAIL ON TREAD SIZE. | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2011 THRU 2012. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
PRV FLOOR DRAIN WITH METAL STR | 6121 S. /REAR BASEMENT LAUNDRY ROOM FLOOR DRAIN METAL STRAINER - MISSING. | 6121 S MICHIGAN AVE | COMPLAINT | PASSED | View |
SCREEN OUTER DOORS, WINDOWS | EAST/NORTH REAR ENTRY DOORS - SCREEN DOORS MISSING THROUGHOUT | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EAST/REAR PORCHES - FOUNDATION STATUS UNKNOWN; 6X6 COLUMNS OVERNOTCHED; SPLICE JOINTS AT SAME LOCATION AS BEAM/COLUMN CONNECTIONS; TREADS SPLITTING FROM GRADE TO 1ST FLOOR; HANDRAILS MISSING FROM GRADE TO BASEMENT; SOUTH REAR PORCH - SPINDLE BROKEN AT HANDRAIL FROM 2ND TO 3RD FLOOR; NORTH REAR PORCH - 3RD FLOOR DECK LEANING EXCESSIVELY; SCUTTLE PANEL MISSING AT 3RD FLOOR. PLANS AND PERMIT REQUIRED TO REPAIR OR REPLACE REAR PORCHES. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | WEST/MANAGEMENT SIGN - FADING | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | EAST/GARAGE - OVERHEAD DOORS BOARDED WITH ROTTING PLYWOOD; SERVICE DOOR AND FRAME BROKEN CREATING GAPS AND OPENINGS; SERVICE DOOR BENT AND WEDGED IN FRAME; WASHED OUT MORTAR, LOOSE BRICKS AT SOUTH PARAPET WALL; TRASH, GARBAGE ON GARAGE APRON. PERMIT REQUIRED TO REPAIR GARAGE. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
INSTALL COVERS | EAST/SOUTH REAR PORCH/EXTERIOR WALL FIXTURES - COVERS MISSING AT 2ND FLOOR | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND CONDITIONS. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR FENCE | EAST/REAR FENCE - TOP RAIL MISSING; REAR GATE LEANING | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | EAST/NORTH REAR PORCH - TRASH, DEBRIS, DIRT THROUGHOOUT - UNSANITARY CONDITIONS | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
CUT OR REMOVE HIGH WEEDS | EAST - FALLEN TREE TRUNK IN REAR YARD | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | EAST - REFRIGERATOR, TELEVISIONS, BEDFRAMES, ETC. ON 3RD FLOOR DECK OF NORTH REAR PORCH | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | EAST - TRASH HANGING FROM 3RD FLOOR REAR PORCH DECK (SOUTH); TRASH, DEBRIS THROUGHOUT NORTH REAR PORCH; REFRIGERATOR, TELEVISIONS, DISCARDED ITEMS AT 3RD FLOOR OF NORTH REAR PORCH; TRASH, GARBAGE AT GARAGE APRON. | 6121 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR BATTERY LIGHT | REPAIR BATTERY LIGHT PUBLIC HALLWAY | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
INSTALL GFCI'S | INSTALL GFCI KITCHEN COUNTER UNPROTECTED RECEPTACLE | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR**************** | REPAIR NON-WORKING RECEPTACLE IN THE BEDROOM (SOUTH WALL) | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE BROKEN INOPERABLE RECEPTACLE FOR STOVE (RANGE) | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
PANEL SCHEDULES | PROVIDE LEGIBLE PANEL SCHEDULES | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
SMOKE & CARBON DETECTORS | INSTALL REQUIRED SMOKE AND CO DETECTORS IN THE BEDROOM | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |
INSTALL GFCI'S | INSTALL GFCI BY KITCHEN SINK | 6121 S MICHIGAN AVE | COMPLAINT | FAILED | View |