REPAIR WINDOW SILLS | ALL WINDOW SILLS MISSING MORTAR AND PEELING PAINT | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR PORCH WING WALL LOOSE BRICKS AND MISSING MORTAR | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
REPAIR FENCE | REAR WOODEN FENCE AND GATE PEELING PAINT | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
ILLUMINATE EXIT AREAS | FRONT PORCH AT 1 LIGHT FIXTURE NO BULB | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
INSTALL DOOR VIEWING DEVICE | ALL APARTMENT DOORS NO PEEPHOLES | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
BASEMENT, DISCONTINUE | BASEMENT UNIT DOES NOT MEET CITY CODES | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
EGRESS -BASEMENT | BASEMENT UNIT NO FRONT EXIT | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT UNIT ALL SEPERATIONS 1/2 DRYWALL | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT UNIT CEILING 6FT 3IN | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
PROVID SELF CLSING SCREEN DVCE | FRONT EXTERIOR SCREEN DOOR AT 1 BENT CLOSER | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | REAR ENCLOSED PORCH AT 1 JUNK AND ALL AROUND PROPERTY DEBRIS | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY AT 2 REAR ENCLOSED PORCH AT ATTIC MISSING SMOKE DETECTORS | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENT NO CARBON MONOXIDE DETECTOR | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN A PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR WOODEN GATE PADLOCKED | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
REPAIR ROOF | FRONT PORCH WOODEN ROOF STRUCTURE ROTTED WOOD AND PEELING PAINT | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT WITHOUT A PERMIT | 5030 S MAPLEWOOD AVE | COMPLAINT | PASSED | View |