Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | BUILDING NO RESPONSE AT BASEMENT AND 2ND FLOORS UNABLE TO VERIFY OCCUAPANCY CONDITIONS AND DETECTORS | 4716 S BISHOP ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN MISSING | 4716 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AND SOUTH ELEVATIONS SIDIDNG BROKEN MISSING | 4716 S BISHOP ST | COMPLAINT | FAILED | View |
ROACHES | 1ST FLOOR KITCHEN ROACHES | 4716 S BISHOP ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | 1ST FLOOR KITCHEN TOILET TANK MISSING LID | 4716 S BISHOP ST | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | SOUTH BASEMENT WINDOWS LOOSE AND MISSING PAINT AND PUTTY | 4716 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED 2 STORY PORCH,UNABLE TO VERIFY COLUMN FOUNDATIONS,COLUMNS ARE4 BY 6 AND ARE OVER 12'.DECK JOISTSARE2 BY 6 AND SPAN 12',WITH NEW 2 BY 12 JOISTS ADDED WITH SECTIONS NOTCH OUT AT NORTH END.STAIRS HAVE NEW RAILINGSFROM GRADE TO 2ND FLOOR.BEAMS ARE 4 BY 6 AND SPAN 7 FEET.PLANS AND PERMIT REQUIRED FOR REPAIRS. | 4716 S BISHOP ST | COMPLAINT | HOLD | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED STAIRS,MISSING SMOKE DETECTOR. | 4716 S BISHOP ST | COMPLAINT | HOLD | View |
PLANS & PERMITS REQ - CONTRCTR | 2ND FLOOR REAR UNIT,SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO 2ND FLOOR REAR OR RESTORE THE BUILDING TO THE ORIGINAL STATE,ALSO REAR 2 STORY ENCLOSED PORCH,NEW FLOOR JOISTS AND HAND RAILS INSTALLED WITHOUT PERMIT ,NO PERMIT ON FILE. | 4716 S BISHOP ST | COMPLAINT | HOLD | View |
WORK NOT ALLOWED | 2ND FLOOR REAR UNIT,OBTAIN PERMIT TO REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN 2ND FLOOR REAR WITHOUT A PERMIT. | 4716 S BISHOP ST | COMPLAINT | HOLD | View |
REPAIR EXTERIOR DOOR | WEST EXTERIOR DOORS ROTTED DELAMINATING | 4716 S BISHOP ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR GATE PADLOCKED | 4716 S BISHOP ST | COMPLAINT | FAILED | View |
EGRESS | 2ND FLOOR REAR UNIT -ONLY ONE EGRESS EXISTS IN THE REAR. | 4716 S BISHOP ST | COMPLAINT | HOLD | View |