Chicago Building Violations Data: 36 Violations
Violation Inspector Comments Address Category Status View
FLAKY INTERIOR PAINT SR-06-00320161 FRONT STAIRS GRADE TO 1 PEELING PAINT 3503 W CORTLAND ST COMPLAINT CLOSED View
OBSTRUCTIONS IN EXIT WAY REAR GATE CHAINED AND PADLOCKED 3503 W CORTLAND ST COMPLAINT CLOSED View
SERVICE WALK, PASSAGE, AREAWAY SERVICE WALK - EAST - SIDEWALK CRACKED 3503 W CORTLAND ST COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION NO ENTRY - OWNER REFUSED ENTRY - GUARD DOG IN REAR YARD - NEED TO MAKE APPOINTMENT FOR INTERIOR INSPECTION AND REAR YARD ACCESS 3503 W CORTLAND ST COMPLAINT CLOSED View
DEBRIS, EXCESSIVE JUNK ACCUMULATION IN REAR YARD 3503 W CORTLAND ST COMPLAINT CLOSED View
REPAIR/REBUILD GARAGE OR SHED GARAGE REPAIR - MISSING FASCIA BOARD (ALLEY) FASCIA BOARD ROTTED,DILAPIDATED SIDING - PEELING PAINT 3503 W CORTLAND ST COMPLAINT CLOSED View
MAINTAIN WINDOW ALL ELEVATION'S/WINDOW FRAMES-PEELING PAINT. 3503 W CORTLAND ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT 1 STORY WOODEN PORCH.4X4 COLUMNS SET ON SOIL,FOUNDATION STATUS UNKNOWN.LEDGER BEAM ONLY FACE NAILED TO BUILDING.JOISTS ONLY FACE NAILED TO SUPPORTS.RIM JOISTS ARE ROTTED.STRINGERS ONLY FACE NAILED AT TOP CONNECTION.STAIR HEADER IS ROTTED.RAILING 4X4 SUPPORTSARE ROTTED AT BASE,RAILINGS ONLY 31 INCHES IN HEIGHT WITH ROTTED RAILS AND PICKETS.REAR ENCLOSED 2 STORY WOODEN PORCH-RAILINGS ARE LADDER TYPE.PERMIT REQUIRED FOR FRONT AND REAR PORCH. 3503 W CORTLAND ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT AND ATTIC APARTMENT,CARBON MONOXIDE DETECTORS OUT OF SERVICE AT TIME OF INSPECTION WITH LOW BATTERY. 3503 W CORTLAND ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY REAR ENCLOSED PORCH STAIRS,GRADE TO ATTIC-BICYCLE'S STORED. 3503 W CORTLAND ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS REAR ENCLOSED PORCH AND ATTIC APARTMENT,SMOKE DETECTOR'S OUT OF SERVICE AT TIME OF INSPECTION WITH LOW BATTERY. 3503 W CORTLAND ST COMPLAINT FAILED View
RATS REAR YARD/JUNK AND REFUSE ACCUMALATING-RAT HARBORAGE. 3503 W CORTLAND ST COMPLAINT FAILED View
REPAIR EAVES REAR ELEVATION/EAVES-ROTTED. 3503 W CORTLAND ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT ELEVATION/EXTERIOR STAIRS GRADE TO BASEMENT-MISSING HAND RAIL. 3503 W CORTLAND ST COMPLAINT FAILED View
MAINTAIN WINDOW ALL ELEVATION'S/WINDOW FRAMES-PEELING PAINT. 3503 W CORTLAND ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM FRONT 1 STORY WOODEN PORCH.4X4 COLUMNS SET ON SOIL,FOUNDATION STATUS UNKNOWN.LEDGER BEAM ONLY FACE NAILED TO BUILDING.JOISTS ONLY FACE NAILED TO SUPPORTS.RIM JOISTS ARE ROTTED.STRINGERS ONLY FACE NAILED AT TOP CONNECTION.STAIR HEADER IS ROTTED.RAILING 4X4 SUPPORTSARE ROTTED AT BASE,RAILINGS ONLY 31 INCHES IN HEIGHT WITH ROTTED RAILS AND PICKETS.REAR ENCLOSED 2 STORY WOODEN PORCH-RAILINGS ARE LADDER TYPE.PERMIT REQUIRED FOR FRONT AND REAR PORCH. 3503 W CORTLAND ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 3503 W CORTLAND ST COMPLAINT PASSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT AND ATTIC WITHOUT A PERMIT. 3503 W CORTLAND ST COMPLAINT PASSED View
CEILING HEIGHT - 7' - BASEMENT BASEMENT APARTMENT CEILING HEIGHT-ONLY 6 FOOT 3 INCHES. 3503 W CORTLAND ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID BASEMENT AND ATTIC APARTMENT,CARBON MONOXIDE DETECTORS OUT OF SERVICE AT TIME OF INSPECTION WITH LOW BATTERY. 3503 W CORTLAND ST COMPLAINT PASSED View
UNINTERRUPTED EXIT AT GRADE BASEMENT APARTMENT FRONT EXIT BLOCKED BY LOCKED SCISSOR GATES IN LIVING ROOM. 3503 W CORTLAND ST COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY REAR ENCLOSED PORCH STAIRS,GRADE TO ATTIC-BICYCLE'S STORED. 3503 W CORTLAND ST COMPLAINT PASSED View
INSTALL SMOKE DETECTORS REAR ENCLOSED PORCH AND ATTIC APARTMENT,SMOKE DETECTOR'S OUT OF SERVICE AT TIME OF INSPECTION WITH LOW BATTERY. 3503 W CORTLAND ST COMPLAINT PASSED View
DEBRIS, EXCESSIVE BASEMENT APARTMENT LIVING ROOM-PERSONAL ITEMS STORED,FLOOR TO CEILING-HOARDING.REAR YARD,LADDERS OLD WASHER,BOXES,PLASTIC BAGS,OLD LUMBER. 3503 W CORTLAND ST COMPLAINT PASSED View
REPAIR BALCONY REAR ELEVATION/1ST FLOOR WOODEN BALCONY.4X4 COLUMNS SET ON SIDEWALK,FOUNDATION STATUS UNKNOWN.4X4 COLUMNS ARE ROTTED.JOISTS ARE 2X4 WITH ROTTED PIECES.RAILINGS ARE ROTTED.PERMIT REQUIRED. 3503 W CORTLAND ST COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS REAR ELEVATION/ATTIC WINDOW BROKEN PANE AND BOARD-UP WINDOW WITH SIDING. 3503 W CORTLAND ST COMPLAINT PASSED View
REPAIR/REBUILD GARAGE OR SHED GARAGE-ROTTED EAVES AND RAFTERS.PERMIT REQUIRED FOR REPAIRS. 3503 W CORTLAND ST COMPLAINT PASSED View
SERVICE WALK, PASSAGE, AREAWAY EAST AND SOUTH ELEVATION/SERVICE WALK-CRACKED AND BUCKLING. 3503 W CORTLAND ST COMPLAINT PASSED View
REPAIR EXTERIOR STAIR FRONT ELEVATION/EXTERIOR STAIRS GRADE TO BASEMENT-MISSING HAND RAIL. 3503 W CORTLAND ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR REAR YARD/8X 10 FOOT 1 STORY SHED BUILT ONTO BUILDING,NO POERMIT OBTAINED. 3503 W CORTLAND ST COMPLAINT PASSED View
REPLACE D&H PORCH FRONT 1-STORY WOOD PORCH - ALL COLUMNS ERECTED ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. ALL DECKING WEAK WITH ROTTING WOOD. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND AT COLUMNS WITH NAILS ONLY. ALL RAILING SECTIONS - LOOSE, WEAK, PULLING; ATTACHED TO COLUMNS AND BUILDING'S WALLS WITH NAILS ONLY. TREADS - WORN OUT, CRACKED AND WEAK. ENTIRE PORCH STRUCTURE - WEAK. PLANS AND PERMIT REQUIRED FOR FRONT PORCH REPLACEMENT.REAR 1-STORY WOOD PORCH - ALL COLUMNS ERECTED ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. ALL DECKING WEAK WITH ROTTING WOOD. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND AT COLUMNS WITH NAILS ONLY. ALL RAILING SECTIONS - LOOSE, WEAK, PULLING; ATTACHED TO COLUMNS AND BUILDING'S WALLS WITH NAILS ONLY. TREADS - WORN OUT, CRACKED AND WEAK. ENTIRE PORCH STRUCTURE - WEAK. PLANS AND PERMIT REQUIRED FOR REAR PORCH REPLACEMENT. 3503 W CORTLAND ST COMPLAINT CLOSED View
SERVICE WALK, PASSAGE, AREAWAY EAST AND SOUTH ELEVATION/SERVICE WALK-CRACKED AND BUCKLING. 3503 W CORTLAND ST COMPLAINT FAILED View
REPAIR EAVES REAR ELEVATION/EAVES-ROTTED. 3503 W CORTLAND ST COMPLAINT PASSED View
UNINTERRUPTED EXIT AT GRADE BASEMENT APARTMENT FRONT EXIT BLOCKED BY LOCKED SCISSOR GATES IN LIVING ROOM. 3503 W CORTLAND ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE-ROTTED EAVES AND RAFTERS.PERMIT REQUIRED FOR REPAIRS. 3503 W CORTLAND ST COMPLAINT FAILED View
RATS REAR YARD/JUNK AND REFUSE ACCUMALATING-RAT HARBORAGE. 3503 W CORTLAND ST COMPLAINT PASSED View