The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANT BUILDING - REGISTER | 7327 S WESTERN AVE | COMPLAINT | CLOSED | View | |
OBTAIN OR POST PERMIT | 7327 S WESTERN AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 7327 S WESTERN AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 7327 S WESTERN AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 7327 S WESTERN AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 7327 S WESTERN AVE | COMPLAINT | CLOSED | View | |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION / 1 STORY PORCH - 12 X 12 MASONRY PIERS, FOUNDATION UNKNOWN. ROTTING WOOD BOARD POSTS ON MASONRY PIERS. DEFICIENTLY SIZED 2X6 FLOOR JOISTS SPANNING 9 FEET. UPPERENDS OF STAIR STRINGERS INADEQUATELY ANCHORED TO JOISTS WITH NAILS ONLY. GUARDRAILS AT HEIGHT OF 33 INCHES THROUGHOUT. LOOSE AND PULLING RAILING SYSTEM THROUGHOUT. ROTTING AND CUPPING TREADS. UNEVEN RISERS AT STAIR FLIGHT RANGING IN HEIGHT FROM 4-1/2 TO 8 INCHES. PLANS AND PERMIT REQUIRED FOR REPAIR / REPLACEMENT OF WEST ELEVATION 1 STORY PORCH. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | WEST ELEVATION / 1 STORY PORCH - ROTTING AND MISSING SECTIONS OF ASPHALT SHINGLES. ROTTING, SAGGING AND DETACHING FASCIA BOARDS. ROTTING AND SAGGING WOOD STRIP FINISH AT UNDERSIDE OF ROOF. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH ELEVATION / SERVICE WALK GATE - CHAINED AND PADLOCKED. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | NORTH, SOUTH AND EAST ELEVATION / MULTIPLE LOCATIONS - ROTTING WINDOW SASHES. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | NORTH, SOUTH AND EAST ELEVATION / MULTIPLE LOCATIONS - ROTTING WINDOW FRAMES. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION / NEAR ROOF - MISSING SECTIONS OF VINYL SIDING. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION / STAIRS FROM GRADE TO 1ST FLOOR - 4X4 POSTS ON CONCRETE SLAB, WITH NO FOUNDATION. ROTTING AND MISSING SECTIONS OF STAIR STRINGER. ROTTING TREADS. LADDER TYPE RAILING SYSTEM WITH HORIZONTAL TIES SPACED 12 INCHES APART. PERMIT ONLY REQUIRED FOR REPAIR / REPLACEMENT OF EAST ELEVATION 1 STORY STAIRS. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EAST ELEVATION / SCREEN DOOR - MISSING GLAZING PANE. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | SOUTH ELEVATION / SERVICE WALK - LOOSE AND MISSING SECTIONS OF WOOD FENCE. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |
PROVID SELF CLSING SCREEN DVCE | EAST ELEVATION / SCREEN DOOR - MISSING SELF CLOSING DEVICE. | 7327 S WESTERN AVE | COMPLAINT | FAILED | View |