Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 8:24 AM
PIN: 20322200160000
Property Address: 8153 S SANGAMON ST
City - Zip: CHICAGO - 60620
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72222
2023 Tax District: 72001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 26 Violations
Violation Inspector Comments Address Category Status View
CUT OR REMOVE HIGH WEEDS BUILDING FENCE 8153 S SANGAMON ST COMPLAINT FAILED View
REPAIR LINTELS LINTELS OPEN JOINTS AND SAGGING, PERMIT FOR REPAIRS 8153 S SANGAMON ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR WEST TREADS RISER, BROKEN CONCRETE, ONE RAIL MISSING AND BASEMENT STAIR 8153 S SANGAMON ST COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY SERVICE WALK, BROKEN CONCRETE 8153 S SANGAMON ST COMPLAINT FAILED View
REPLACE D&H PORCH EAST PORCH IMPROPER RAIL HEIGHT, LOOKOUTS ROTTED RAILS LOOSE, LAP JOINT NO BOLTS, UPRIGHT OVERCUT, NAILS COMING UP FROM TREADS, NO JOIST HANGER, DECK JOIST IMPROPER SUPPORT, MIDDLE UPRIGHT ROTTED, STRINGER WOOD SPLIT TREAD WINDERS LOOSE, STRINGER LEDGER BOARD NO BOLTS STRINGER NOT SEAL IN POCKET, NO FOOTING, SUBMIT PLANS AND PERMITS. 8153 S SANGAMON ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE OVERHEAD DOOR FRAME ROTTED, EXTERIOR WALL MORTAR MISSING. 8153 S SANGAMON ST COMPLAINT FAILED View
CHIMNEY CHIMNEY LOOSE BRICKS, MORTAR MISSING. 8153 S SANGAMON ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# POST OWNERSHIP 8153 S SANGAMON ST COMPLAINT FAILED View
DEBRIS, EXCESSIVE PORCH AREA, UNDER PORCH AREA 8153 S SANGAMON ST COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS WINDOW SCREEN MISSING 8153 S SANGAMON ST COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING APT. - 1 / CEILING AT BATHROOM DOOR - WATER DAMAGE. 8153 S SANGAMON ST COMPLAINT FAILED View
MAINTAIN WINDOW SASH ENCLOSE PORCH WINDOW SASHES ROTTED 8153 S SANGAMON ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL MORTAR MISSING 8153 S SANGAMON ST COMPLAINT FAILED View
PARAPET PARAPET WALL, MORTAR MISSING 8153 S SANGAMON ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED THE REAR MASONRY GARAGE HAS BRICKWORK IN NEED OF TICKPOINTING (STRESS FRACTURES EXIST). THERE ARE 2 OVERHEAD DOORS WITH WOODEN STRUCTURAL HEADER BEAMS. THESE BEAMS ARE SEVERELY WOOD ROTTED AND MUST BE REPLACED. IN LIEU OF ARCHITECHURAL DRAWINGS, REPAIRS ARE TO BE MADE BASED ON A STRUCTRURAL ENGINEERS REPORT SO AS TO ACQUIRE THE PROPER PERMIT. THE CONDITION OF THE GARAGE OVERHEAD DOOR HEADERS IS DANGEROUS AND HAZARDOUS.SECTION 14X-3-303.1.1 8153 S SANGAMON ST COMPLAINT FAILED View
SUBMIT 2 COPY STRUCTURAL RPT THIS REPORT IS TO ASSESS THE CONDITION OF THE GARAGE OVER HEAD DOOR BEAMS IN ORDER TO PROVIDE A TEMPLATE FOR REPAIRS AND TO ACQUIRE A REPAIR PERMIT.SECTION 14X-1-104.1 8153 S SANGAMON ST COMPLAINT FAILED View
REPAIR LINTELS THE FRONT, 2CD FLOOR WINDOW LINTELS ARE SEVERELY RUSTED / WARPED / SAGGING. THIS CONDITION REDUCES THE STRUCTURAL CAPACITY FOR THESE LINTELS TO SUPPORT THE BRICKWORK ABOVE (DANGEROUS AND HAZARDOUS). THERE ARE 4 LINTELS, ONE OF WHICH IS OVE 6' WIDE (16') AND REQUIRES DRAWINGS TO ACQUIRE THE PERMIT. THE OTHER THREE LINTELS ARE 3' WIDE AND REQUIRE AN EPP REPAIR / REPLACE PERMIT.SECTION 14X-3-303.1.1 8153 S SANGAMON ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS A 1ST FLOOR (SOUTH) WINDOW PANE IS SHATTERED.SECTION 14X-4-403.4 8153 S SANGAMON ST COMPLAINT FAILED View
INSTALL EXTRA SMOKE DETECTORS APT. - 1 / FRONT BEDROOM AREA / SMOKE DETECTOR MISSING. 8153 S SANGAMON ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL WEST ELEVATION / EXTERIOR WALL FROM GRADE TO 1ST FLOOR / FRACTURED MASONRY WITH WASHED OUT MORTAR. 8153 S SANGAMON ST COMPLAINT FAILED View
REPAIR LINTELS WEST, SOUTHWEST, AND NORTHWEST ELEVATIONS / LINTELS RUSTED SAGGING AND DETERORATING. PLANS AND PERMIT REQUIRED FOR LINTEL REPAIRS. 8153 S SANGAMON ST COMPLAINT FAILED View
REPAIR / REBUILD SHED EAST ELEVATION / MASONRY GARAGE / EAST OVERHEAD DOOR HEADER ON VERGE OF COLLAPSE. HEADER IS PROPPED UO WITH SCREW JACK, 2X8 AND 4X4 BLOCK. ROOF IS SAGGING IN CENTER AT OVERHEAD DOOR HEADER. EXTERIOR WALLS FRACTURED MASONRY WITH WASHED OUT MORTAR. PLANS AND PERMIT REQUIRED TO REPAIR GARAGE. PERMIT REQUIRED TO DEMOLISH GARAGE. PERM 8153 S SANGAMON ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - OWNER'S ID SIGN NOT POSTED. 8153 S SANGAMON ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID APT. - 1 CARBON MONOXIDE DETECTOR - MISSING. 8153 S SANGAMON ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY REAR PORCH / COOKING STOVE BEING STORED ON 1ST FLOOR PORCH DECK. 8153 S SANGAMON ST COMPLAINT FAILED View
ROACHES APT. - 1 / KITCHEN - ROACHES OBSERVED AT TIME OF INSPECTION. 8153 S SANGAMON ST COMPLAINT FAILED View