Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO APT INTERIOR FOR SMOKE DETECTOR AND CARBON MONOXIDE DETECTOR VERIFICATION NO ENTRY TO REAR PORCH. | 5647 S DORCHESTER AVE | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | REAR WOOD PORCH VIEWED FROM SOUTH PARKING LOT COLUMNS SUPPORTED ON CONCRETE BLOCKS SOUTH END OF PORCH LEVELS 1-3 OPEN BEAM POCKETS OBTAIN PLANS AND PERMIT | 5647 S DORCHESTER AVE | PERIODIC | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRWELL ONE RISER BROKEN GRADE TO 1ST FLOOR MISSING HANDRAIL | 5647 S DORCHESTER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH ELEVATION GRADE TO BASEMENT MISSING RAILING | 5647 S DORCHESTER AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 1ST FLOOR ONE PICKET MISSING REAR PORCH | 5647 S DORCHESTER AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | BASEMENT AROUND ELECTRIC METERS SOME JUNK TRASH | 5647 S DORCHESTER AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | N3 STORY GREAR PORCH. TTHE MAION COLUMN FO OTINGS ARE OSF AN UNDEETERMINED DEPTHP. THESEA COLUMN SECTIONS RARE JOINED BY ASUBSTANDARTD LAP EJOINTS 12"-2 BOLT JOINERY. ALL OF THESE COLUMNS ARE OVER NOTCH CUT. THE STRUCTURAL RIM BEAMS ARE NAILED TO THE PORCH STRUCTURE NOT BOLTED WITH THESE NAILED JOINTS BEGINING TO SEPARATE. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 5647 S DORCHESTER AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT INFO POSTED | 5647 S DORCHESTER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR | 5647 S DORCHESTER AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT INFO POSTED | 5647 S DORCHESTER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR | 5647 S DORCHESTER AVE | PERIODIC | FAILED | View |
SYSTEM III | INSTALL SYSTEM III EMERGENCY LIGHTING TO INCLUDE BATTERY LIGHTS AND BATTERY BACK UP EXIT SIGNS | 5647 S DORCHESTER AVE | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | REPAIR DEFECTIVE LIGHT SWITCH AT APARTMENT 11 LIVING ROOM | 5647 S DORCHESTER AVE | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | REPAIR DEFECTIVE LIGHTING AT APARTMENT 11 BEDROOM AND REAR EXTERIOR PORCH LIGHTING AT 3RD FLOOR A PERMIT IS REQUIRED FOR CORRECTION OF ELECTRICAL VIOLATIONS | 5647 S DORCHESTER AVE | COMPLAINT | PASSED | View |
PARAPET | SOUTH ELEVATION/ PARAPET WALL - SPALLING BRICKS WITH WASHED OUT MORTAR NEAR TOP. | 5647 S DORCHESTER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 5647 S DORCHESTER AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | SOUTHWEST CORNER/ GRADE TO BASEMENT EXTERIOR STAIRWAY/ GUARD RAIL AT GRADE - LADDER TYPE WITH WITH APPROXIMATELY 16 TO 18 INCHES BETWEEN MEMBERS; MISSING PICKETS. | 5647 S DORCHESTER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ENTRY REFUSED AT FRONT DOOR BY FEMALE OCCUPANT. ALL APARTMENTS AND INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS, COMPLAINT OF INADEQUATE HEAT AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS AND REAR PORCH. | 5647 S DORCHESTER AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | NOT REGISTERED 2005-2006 | 5647 S DORCHESTER AVE | PERIODIC | FAILED | View |