PLANS & PERMITS REQUIRED | NO PLAN AND PERMIT ON FILE FOR ROLLING WROUGHT IRON GATE. | 2535 W 59TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AND EAST ELKEVATION 2ND FLOOR OVER WINDOWS SHIFTING STONES. | 2535 W 59TH ST | COMPLAINT | FAILED | View |
REPAIR COPING | NORTH AND EAST ELEVATION STONE COPINGS HAVE WASHED OUT MORTAR JOINTS. | 2535 W 59TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO GROCERY STORE TO VERIFY COMPLAINT OF RODENTS AND NO HOT WATER.UNABLE TO GAIN ENTRY TO REAR OF BUILDING TO INSPECT 2 STORY BACK PORCHES. | 2535 W 59TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 2535 W 59TH ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | FRONT STORE PILES A CLOSE ON THE FLOOR 4' X3' .REMOVE | 2535 W 59TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRS TOP FLOOR NO SMOKE DETECTOR. | 2535 W 59TH ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH ELEVATION 2ND FLOOR ROTTED WINDOW FRAME. | 2535 W 59TH ST | COMPLAINT | FAILED | View |
REPAIR COPING | EAST AND NORTH ELEVATION - COPING OPEN MORTAR JOINT. | 2535 W 59TH ST | COMPLAINT | FAILED | View |
PARAPET | EAST AND WEST ELEVATION - PARAPET WASHED OUT MORTAR AND STEP CRACKS AND SPALLING BRICK.MASON PERMIT REQUIRED. | 2535 W 59TH ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | NORTH ,SOUTH AND EAST ELEVATION - IRON FENCE WITH METAL DECKING 180'X6' PERMIT REQUIRED.REAR PORCH AT GRADE NEWER CMU WALL BUILT WITHOUT PERMIT | 2535 W 59TH ST | COMPLAINT | FAILED | View |
REPAIR CORNICE | FRONT CORNICE CRACKED AND OPEN JOINT | 2535 W 59TH ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | NORTH ELEVATION - (2) 3' AND(2) 6' LIINTELS RUSTED AND SAGGING.EAST ELEVATION (2) 6' LINTEL SAGGING AND RUSTED PLANS AND PERMIT REQUIRED FOR REPLACING LINTEL | 2535 W 59TH ST | COMPLAINT | FAILED | View |
PROTECT SIDEWALK DURING CONST | NORTH AND EAST ELEVATION CANOPY REQUIRED FOR REPAIRS TO LINTEL | 2535 W 59TH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR IRON ROLLING GATE 15'X7' HIGH PLANS AND PERMIT REQUIRED WEST ELEVATION - 18'X18' NEW SHEDCOLUMNS ERECTED ON DIRT. PLANS AND PERMIT REQUIRED. REAR PORCH GRADE TO 2ND FLOOR STINGERS NOT STABLE TREADS 2X6JOIST 2X6 12' SPAN WEST ELEVATION EXPOSED PLYWOOD GUARD RAILS AND STRINGERS NAILED TO COLUMNS,HEADERS AND WALL.PLANS AND PERMIT REQUIRED. | 2535 W 59TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FL APT NO CARBON MONOXIDE. | 2535 W 59TH ST | COMPLAINT | FAILED | View |