The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 4748 S WOOD ST | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQUIRED | NO PLAN AND PERMIT ON FILE FOR 8FT TALL CORROGATED STEEL ROLLING GATE AND STEEL CARPORT. | 4748 S WOOD ST | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | APT 1 R / WALL HEATER - FOR ALL THE APT . PER SECTION CODE (14X-3-305.1, 14X-8-804.1, 14X-8-804.4 AND 14X-8-804.5) BHA CODES | 4748 S WOOD ST | COMPLAINT | CLOSED | View |
UNAPPROVED HEATING DEVICE | APT 1R / ELECT HEATERS - USED FOR HEAT PER SECTION CODE . (14X-7-705.4 | 4748 S WOOD ST | COMPLAINT | CLOSED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THRU 2015. | 4748 S WOOD ST | COMPLAINT | CLOSED | View |
FILE BLDG REGISTRATION | BUILDING (4 DWELLING UNITS)-NOT REGISTERED. | 4748 S WOOD ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN-NOT POSTED. | 4748 S WOOD ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRS (7 FT-7IN HEIGHT)- MISSING FOOTINGS; UNDERSIZED 4X4 COLUMNS ARE SET ON TOP OF WOOD PIECES THAT ARE SET ON TOP OF MASONRY BLOCKS.MISSING LEDGER BOLTS. EDGE BEAMS ARE ONLY NAILED / SCREWED INTO THE COLUMN / POST CONNECTIONS. DECK JOISTS ARE ONLY NAILED / SCREWED INTO THE LEDGER / EDGE BEAM CONNECTIONS. MOST COMPONENTS / RAILS ARE ONLY NAILED / SCREWED AT THE CONNECTIONS. SOUTH EXTERIOR STAIRS-STAIR SYSTEM IS NOT ATTACHED TO THE BUILDING. UNDERSIZED 2X4 DECK JOISTS ARE SET AT 32 INCHES ON CENTER / APART. LOOSE RAILS WITH HORIZONTAL MEMBERS IN LIEU OF VERTICAL PICKETS. MOST COMPONENTS / RAILS ARE ONLY NAILED SCREWED AT THE CONNECTIONS. SOUTH FIRE ESCAPE-VERTICAL SUPPORT POSTS ARE RUSTED THROUGH; MOST COMPONENTS ARE RUSTED. SUBMIT PLANS AND OBTAIN PERMIT FOR FRONT EXTERIOR STAIR SYSTEM REPAIRS / ONLY PERMIT REQUIRED FOR SOUTH EXTERIOR STAIR SYSTEM REPAIRS / ONLY PERMIT REQUIRED FOR FIRE ESCAPE REPAIRS; REPAIRS ARE SUBJECT TO FIELD INSPECTION WITH THE IRON BUREAU. | 4748 S WOOD ST | COMPLAINT | FAILED | View |
ABANDONED REFRIGERATOR | REFRIGERATOR WITH DOORS ATTACHED. | 4748 S WOOD ST | COMPLAINT | FAILED | View |
REMOVE | WOODEN SHED (12 FT X 17 FT X 8 FT)-INSTALLED IN THE YARD AND ONLY ONE FEET AWAY FROM THE NORTH ADJACENT PROPERTY. | 4748 S WOOD ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | STEEL AND WOODEN CARPORT (25 FT X 25 FT X 10FT WITH 9 FT-6 INCH ROLLING GATE) INSTALLED AT THE REAR OF THE PROPERTY WITHOUT A PERMIT. | 4748 S WOOD ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED DETECTORS AND COMPLAINT OF: SR#162067643 - PIGEONS BEING KEPT IN THE ATTIC. | 4748 S WOOD ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING (4 DWELLING UNITS)-NOT REGISTERED. | 4748 S WOOD ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING (4 DWELLING UNITS)-NOT REGISTERED. | 4748 S WOOD ST | COMPLAINT | FAILED | View |