Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | NO OWNER'S / MANAGEMENT SIGN POSTED. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | MISSING AND TORN WINDOW SCREENS. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW PANES. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION - SPALLING BRICKS AND WASHED OUT MORTAR, LOOSE PARGING COAT AT GRADE. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 1. ROTTED WOOD THRU-OUT.2. 6X6 COLUMNS RESTING ON CONCRETE SLAB.3. FOUNDATION STATUS UNKNOWN.4. BEAM TO COLUMN CONNECTIONS INADEQUATE.5. LOOKOUT BEAMS OVER SPANNED AND SEPERATING FROM COLUMNS.6. 2X8 JOIST OVER SPANNED.7. STRINGERS INADEQUATELY SUPPORTED.8. GUARDRAILS UNDER 42 INCHES IN HEIGHT.9. PLANS AND PERMIT REQUIRED. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | FRONT BALCONY1. LEDGER BEAM INADEQUATELY SUPPORTED AT BUILDING.2. SINGLE 2X8 BEAM UNDERSIZED FOR SPAN.3. 2X6 JOIST INADEQUATELY SUPPORTED AT LEDGER BEAM.4. OPEN BEAM POCKETS.5. PERMIT REQUIRED. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION / 1ST FLOOR WINDOW-BOARDED UP. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FRONT ELEVATION / IRON FENCE GATE-BROKEN BOTTOM RAIL.FRONT ELEVATION / INRON FENCE GATE-BROKEN BOTTOM RAIL. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING / NO ENTRY,UNVERIFIED DETECTORS,OCCUPANCY,CONDITIONS. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING GUARD RAIL. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING HAND RAIL. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT ELEVATION,EXTERIOR STAIRS,GRADE TO BASEMENT,MISSING HAND RAIL. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT ELEVATION,EXTERIOR STAIRS GRADE TO BASEMENT,MISSING GUARD RAIL. | 1920 N KARLOV AVE | COMPLAINT | FAILED | View |