Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:12 PM
PIN: 13281070230000
Property Address: 5230 W BARRY AVE
City - Zip: CHICAGO - 60641
2023 Property Class: 203
2023 Township: 71 - Jefferson
2023 Neighborhood: 71260
2023 Tax District: 71033
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 21 Violations
Violation Inspector Comments Address Category Status View
VACANT BUILDING - REGISTER 5230 W BARRY AVE COMPLAINT CLOSED View
SEPARATION OF DWELLING ADEQUAT BASEMENT CEILING WITH EXPOSED JOISTS AREAS INSIDE OF BOILER ROOM.2.-UNKNOWN CEILING MATERIAL AT COVERED AREAS. 5230 W BARRY AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING BASEMENT AND FIRST FLOOR APARTMENTS WITH MULTIPLE WALL AND CEILING AREAS DAMAGED BY WATER OR FORCE. 5230 W BARRY AVE COMPLAINT FAILED View
REPAIR FLOOR KITCHEN FLOOR AREA WITH MULTIPLE CERAMIC FLOOR TILES BROKEN AND/OR MISSING. 5230 W BARRY AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS MULTIPLE BOARDED UP WINDOW WITH THE PANES BROKEN AND/OR MISSING. 5230 W BARRY AVE COMPLAINT FAILED View
CARPETING INTERIOR STAIR SYSTEM FROM 1ST TO ATTIC WITH LOOSE AND TORN CARPETING. 5230 W BARRY AVE COMPLAINT FAILED View
PROVIDE INTERIOR STAIR SYSTEM FROM THE FIRST FLOOR TO THE ATTIC DOES NOT HAVE THE RISER HEIGHT AND THE TREAD WIDTH AS REQUIRED PER 10(13-160-3000) 2.-THE HAND RAIL IS MISSING AND THE FLIGHT OF STAIRS WITH MULTIPLE LOOSE TREADS. 5230 W BARRY AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE REMOVE OLD AND ROTTING LADDER, LUMBER AND OTHER JUNK LOCATED AT THE REAR YARD. 5230 W BARRY AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING BASEMENT AND FIRST FLOOR APARTMENTS WITH MULTIPLE WALL AND CEILING AREAS DAMAGED BY WATER OR FORCE. 5230 W BARRY AVE COMPLAINT FAILED View
PROVIDE INTERIOR STAIR SYSTEM FROM THE FIRST FLOOR TO THE ATTIC DOES NOT HAVE THE RISER HEIGHT AND THE TREAD WIDTH AS REQUIRED PER 10(13-160-3000) 2.-THE HAND RAIL IS MISSING AND THE FLIGHT OF STAIRS WITH MULTIPLE LOOSE TREADS. 5230 W BARRY AVE COMPLAINT FAILED View
DEMO DEBRIS CONSTRUCTION DEBRIS FRONT AND REAR YARD. 5230 W BARRY AVE COMPLAINT FAILED View
SEPARATION OF DWELLING ADEQUAT BASEMENT CEILING WITH EXPOSED JOISTS AREAS INSIDE OF BOILER ROOM.2.-UNKNOWN CEILING MATERIAL AT COVERED AREAS. 5230 W BARRY AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR 1.-SOUTH ELEVATION WINDOW AT GRADE WAS EXTENDED TO THE BASEMENT FLOOR TO PROVIDE FOR A DOOR OPENING, FOUNDATION WALL CUT AND DOOR ADDED. 2.-SOUTH ELEVATION CONCRETE STEPS AND RETAINING WALLS POURED TO PROVIDE ACCESS TO BASEMENT APARTMENT. 3.-BASEMENT AREA ALTERED TO INCLUDE A FAMILY UNIT, PARTITIONS WERE ERECTED TO CREATE ROOMS, SEE FULL KITCHEN, BATHROOM, LIVING ROOM AND BEDROOMS. 4.-ATTIC STORAGE AREA ALTERED TO INCLUDE A BATH ROOM AND TWO BEDROOMS. 5.-GARAGE ERECTED HIGHER AND WIDER THAN ALLOWED. 5230 W BARRY AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT EXTERIOR STAIR SYSTEM WITH BROKEN AND CRUMBLING STEPS. 2.-REAR CONCRETE STEPS ARE WAY OUT OF LEVEL, ENTIRE SYSTEM IS SINKING AND TILTED, THE HAND RAILS ARE TOO LOW AND WITH PICKET SPACING TOO WIDE, WEAK ANCHOR AREAS..3.-NORTH AND SOUTH GRADE TO BASEMENT CONCRETE STEPS WITH OUT A HAND RAIL. 5230 W BARRY AVE COMPLAINT FAILED View
CEILING HEIGHT - 7' - BASEMENT BASEMENT CEILING UNDER 7 FT. 5230 W BARRY AVE COMPLAINT FAILED View
WINDOW AREA ABOVE GROUND BASEMENT AREA WITH INSUFFICIENT WINDOW AREA TO PROVIDE LIGHT AND VENTILATION. OTHER WINDOW OPENINGS HAVE BEEN REPLACED WITH GLASS BLOCKS. 5230 W BARRY AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH GRADE TO BASEMENT CONCRETE RETAINING WALLS WITH OUT GUARD RAILS. 5230 W BARRY AVE COMPLAINT FAILED View
CONNECT GAS APPLIANCE TO VENT HOT WATER HEATER HAS THE FLUE PIPE CONNECTED TO THE CHIMNEY WITH A NEGATIVE PITCH. 5230 W BARRY AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMITS REQUIRED FOR THE FOLLOWING FULL GUT AND REHAB BASEMENT DUPLEX WITH FIRST FLOOR,1ST FLOOR DUPLEX WITH ATTIC DORMER INSTALLED ON EAST SIDE OF ATTIC WITH NO SET BACK WALLS REMOVED THROUGH- OUT AND BEAMS INSTALLED TO CREATE AND OPEN FLOOR PLAN,HEATING SYSTEM WAS REPLACE FROM HOT WATER TO FURNACE. PLUMBING,,ELECTRICAL AND H.V.A.C.TO BE INCLUDED.SUBJECT APPROVAL BY ALL RELATED TRADES. 5230 W BARRY AVE COMPLAINT FAILED View
PERMIT REQUIRED STOP WORK ORDER SECT.13-12-050,13-12-080,13-32-035 UNTIL PERMIT IS OBTAIN. 5230 W BARRY AVE COMPLAINT FAILED View
CHIMNEY HEIGHT EAST CHIMNEY FLUE PIPE CENTER OF WINDOW OF DORMER.CHIMNEY HEIGHT BELOW NEW DORMER WINDOW. 5230 W BARRY AVE COMPLAINT FAILED View