Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANT BUILDING - REGISTER | 5230 W BARRY AVE | COMPLAINT | CLOSED | View | |
SEPARATION OF DWELLING ADEQUAT | BASEMENT CEILING WITH EXPOSED JOISTS AREAS INSIDE OF BOILER ROOM.2.-UNKNOWN CEILING MATERIAL AT COVERED AREAS. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT AND FIRST FLOOR APARTMENTS WITH MULTIPLE WALL AND CEILING AREAS DAMAGED BY WATER OR FORCE. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | KITCHEN FLOOR AREA WITH MULTIPLE CERAMIC FLOOR TILES BROKEN AND/OR MISSING. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | MULTIPLE BOARDED UP WINDOW WITH THE PANES BROKEN AND/OR MISSING. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
CARPETING | INTERIOR STAIR SYSTEM FROM 1ST TO ATTIC WITH LOOSE AND TORN CARPETING. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
PROVIDE | INTERIOR STAIR SYSTEM FROM THE FIRST FLOOR TO THE ATTIC DOES NOT HAVE THE RISER HEIGHT AND THE TREAD WIDTH AS REQUIRED PER 10(13-160-3000) 2.-THE HAND RAIL IS MISSING AND THE FLIGHT OF STAIRS WITH MULTIPLE LOOSE TREADS. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REMOVE OLD AND ROTTING LADDER, LUMBER AND OTHER JUNK LOCATED AT THE REAR YARD. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT AND FIRST FLOOR APARTMENTS WITH MULTIPLE WALL AND CEILING AREAS DAMAGED BY WATER OR FORCE. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
PROVIDE | INTERIOR STAIR SYSTEM FROM THE FIRST FLOOR TO THE ATTIC DOES NOT HAVE THE RISER HEIGHT AND THE TREAD WIDTH AS REQUIRED PER 10(13-160-3000) 2.-THE HAND RAIL IS MISSING AND THE FLIGHT OF STAIRS WITH MULTIPLE LOOSE TREADS. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | CONSTRUCTION DEBRIS FRONT AND REAR YARD. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT CEILING WITH EXPOSED JOISTS AREAS INSIDE OF BOILER ROOM.2.-UNKNOWN CEILING MATERIAL AT COVERED AREAS. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | 1.-SOUTH ELEVATION WINDOW AT GRADE WAS EXTENDED TO THE BASEMENT FLOOR TO PROVIDE FOR A DOOR OPENING, FOUNDATION WALL CUT AND DOOR ADDED. 2.-SOUTH ELEVATION CONCRETE STEPS AND RETAINING WALLS POURED TO PROVIDE ACCESS TO BASEMENT APARTMENT. 3.-BASEMENT AREA ALTERED TO INCLUDE A FAMILY UNIT, PARTITIONS WERE ERECTED TO CREATE ROOMS, SEE FULL KITCHEN, BATHROOM, LIVING ROOM AND BEDROOMS. 4.-ATTIC STORAGE AREA ALTERED TO INCLUDE A BATH ROOM AND TWO BEDROOMS. 5.-GARAGE ERECTED HIGHER AND WIDER THAN ALLOWED. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIR SYSTEM WITH BROKEN AND CRUMBLING STEPS. 2.-REAR CONCRETE STEPS ARE WAY OUT OF LEVEL, ENTIRE SYSTEM IS SINKING AND TILTED, THE HAND RAILS ARE TOO LOW AND WITH PICKET SPACING TOO WIDE, WEAK ANCHOR AREAS..3.-NORTH AND SOUTH GRADE TO BASEMENT CONCRETE STEPS WITH OUT A HAND RAIL. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT CEILING UNDER 7 FT. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
WINDOW AREA ABOVE GROUND | BASEMENT AREA WITH INSUFFICIENT WINDOW AREA TO PROVIDE LIGHT AND VENTILATION. OTHER WINDOW OPENINGS HAVE BEEN REPLACED WITH GLASS BLOCKS. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GRADE TO BASEMENT CONCRETE RETAINING WALLS WITH OUT GUARD RAILS. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
CONNECT GAS APPLIANCE TO VENT | HOT WATER HEATER HAS THE FLUE PIPE CONNECTED TO THE CHIMNEY WITH A NEGATIVE PITCH. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS REQUIRED FOR THE FOLLOWING FULL GUT AND REHAB BASEMENT DUPLEX WITH FIRST FLOOR,1ST FLOOR DUPLEX WITH ATTIC DORMER INSTALLED ON EAST SIDE OF ATTIC WITH NO SET BACK WALLS REMOVED THROUGH- OUT AND BEAMS INSTALLED TO CREATE AND OPEN FLOOR PLAN,HEATING SYSTEM WAS REPLACE FROM HOT WATER TO FURNACE. PLUMBING,,ELECTRICAL AND H.V.A.C.TO BE INCLUDED.SUBJECT APPROVAL BY ALL RELATED TRADES. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED | STOP WORK ORDER SECT.13-12-050,13-12-080,13-32-035 UNTIL PERMIT IS OBTAIN. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |
CHIMNEY HEIGHT | EAST CHIMNEY FLUE PIPE CENTER OF WINDOW OF DORMER.CHIMNEY HEIGHT BELOW NEW DORMER WINDOW. | 5230 W BARRY AVE | COMPLAINT | FAILED | View |