Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEFECTIVE FIXTURES | REPLACE DEFECTIVE RUSTED AND UNAPPROVED FOR OUTSIDE USE LIGHT FIXTURE ABOVE REAR EXTERIOR DOOR AT THE SOUTH EXTERIOR | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | REMOVE EXPOSED WIRING AT CEILING OF BASEMENT EXTERIOR STAIRWELL | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | REAR ENCLOSED PORCH WINDOW ROTTING FRAMES WITH FLAKY PAINT | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIR TO BASEMENT MISSING HANDRAIL | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | FAILURE TO INSTALL GFCI RECEPTACLES IN ALL REQUIRED LOCATIONS AT 1ST FLOOR KITCHEN. 18-27-570-8 | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
INTERIOR FINISH FIRERESISTANCE | BASEMENT WALL PANELING | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
SUPPORT OUTLET AND JBOX | SECURE ALL LOOSE DEVICES THROUGHOUT BASEMENT, SPECIFICALLY PUTLET BEHIND TV IN MIDDLE ROOM, AND SWITCH IN BATHROOM. | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION STAIR TO BASEMENT MISSING HANRAIL | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | FAILURE TO INSTALL GFCI OUTLETS SOUTH EXTERIOR - EYE PLATE AND SERVICE HEAD FOR ELECTRICAL SERVICE ARE NOT PROPERLY ATTACHED | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
ROACHES | ROACHES PROBLEMS | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
INSTALL COVERS | INSTALL COVERS ON OPEN JUNCTION BOXES AND DEVICES THROUGHOUT BASEMENT. SPECIFICALLY BATHROOM, LAUNDRY ROOM, AND MIDDLE ROOM. | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | REAR ENCLOSED PORCH WINDOW PUTTY | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
SECURE SEC | SOUTH EXTERIOR - SERVICE ENTRANCE CABLE FOR SERVICE RISER IS NOT STRAPPED PROPERLY | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | REAR ENCLOSED FLOOR MISSING FILE KILT ROTTING WOOD | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE BROKEN RECEPTACLES NEXT TO BASEMENT DOOR | 4825 W THOMAS ST | COMPLAINT | FAILED | View |
REMOVE | FRONT BEDROOM DOOR WITH DEADBOLT LOCK | 4825 W THOMAS ST | COMPLAINT | FAILED | View |