The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR DOOR HARDWARE | SR#06-02217984 FRONT DOOR MISSING DOOR KNOB | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH PORCH GUARDRAILS LESS 42" & LOOSE ON 1ST FLOOR COLUMN - BEAM CONNECTION MISSING STEEL BRACKETS | 3609 W PALMER ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST MANAGEMENT INFORMATION | 3609 W PALMER ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING-REFUSED ENTRY UNVERIFIED DETECTORS UNABLE TO VERIFY COMPLAIN OF "SMOKE DETECTORS DISABLED'. | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ENTRY DOOR BROKE PANEL EAST BASEMENT DOOR BROKEN WON'T CLOSE | 3609 W PALMER ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR-ABANDONED VEHICLE | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH COLUMNS ERECTED ON SOIL BEAMS ATTACHED TO COLUMN WITH NAILS ONLY. UNDERSIZED 2'X6" FLOOR JOIST USED OVER 9' LONG SPANS, FLOOR JOIST ARE TOE-NAILED TO HEADER JOIST, RAILING SECTIONS ARE ONLY 38" HIGH PLANS AND PERMIT REQUIRED TO REPAIR PORCH. | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT STAIR LEDGER BEAM ATTACHED TO MASONRY WALL WITH NAILS ONLY, JOISTS TOE-NAILED TO HEADER.STRINGER ATTACHED TO COLUMN WITH NAILS ONLY, RAILING SECTION ARE ONLY 34" HIGH. PERMIT ONLY, NO PLANS REQUIRED FOR REPAIR. | 3609 W PALMER ST | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | PIGEON FOULING AT REAR PORCH | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | HOLE IN 1ST FLOOR BEDROOM WALL AND FRONT STAIRWELL WALL | 3609 W PALMER ST | COMPLAINT | FAILED | View |
ABANDONED REFRIGERATOR | REFRIGERATOR AT 1S FLOOR REAR, PORCH DECK | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | STAIRS 1ST AND 2ND FLOOR: WEAK TREADS AND LOOSE HANDRAILS | 3609 W PALMER ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REMOVE GRILLS FROM 1ST AND 2ND FLOOR REAR PORCH DECKS, GRAFFITI AT REAR | 3609 W PALMER ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR AT 1ST FLOOR | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | GAP ALL AROUND 1ST FLOOR APARTMENT SOUTH DOOR | 3609 W PALMER ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT TO UPGRADE PORCH INTO TODAY'S SAFETY STANDARD | 3609 W PALMER ST | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | MISSING PEEPHOLES AT 1ST AND 2ND FLOOR | 3609 W PALMER ST | COMPLAINT | FAILED | View |
PROVID SELF CLSING SCREEN DVCE | MISSING SCREEN DOOR CLOSERS, 1ST AND 2ND FLOOR SOUTH | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | BROKEN HANDLE, 2ND FLOOR SCREEN DOOR HANDLE | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | BROKEN FLOOR TILE, KITCHEN AND LIVING ROOM 2ND FLOOR; WEAK, DEFECTIVE FLOORING AT 2ND FLOOR BATHROOM | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH: OVERSPANNED FLOOR JOISTS | 3609 W PALMER ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT TO BRING PORCH TO CURRENT CHICAGO CODE | 3609 W PALMER ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES ON 2ND FLOOR AND FIXTURES ON REAR PORCH BASEMENT TO 2ND FLOOR | 3609 W PALMER ST | COMPLAINT | FAILED | View |
INSTALL COVERS | INSTALL COVER TO 2ND FLOOR BEDROOM SWITCH | 3609 W PALMER ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE PHOTO CELL ON REAR EXTERIOR OF BUILDING | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR FENCE | BROKEN TOP RAIL, REAR CHAIN LINK FENCE | 3609 W PALMER ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | OBTAIN ELECTRICAL PERMIT BEFORE STARTING WORK, 13-12-360 | 3609 W PALMER ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | YARD & PORCH JUNK & REFUSE | 3609 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | HOLE IN 1ST FLOOR BEDROOM DOOR | 3609 W PALMER ST | COMPLAINT | FAILED | View |