The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT FOR PARTITIONS WALLS KITCHEN AND BATHROOM. | 4512 N CENTRAL PARK AVE | COMPLAINT | CLOSED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT TO RESTORE BASEMENT TO ORIGINAL USE. | 4512 N CENTRAL PARK AVE | COMPLAINT | CLOSED | View |
CEILING HEIGHT - 7' - BASEMENT | CEILING TO LOW UNDER 7'. | 4512 N CENTRAL PARK AVE | COMPLAINT | CLOSED | View |
NATURAL LIGHT NEEDED | PROVIDE NATURAL LIGHT. | 4512 N CENTRAL PARK AVE | COMPLAINT | CLOSED | View |
PAINT SHUT | PROVIDE ADEQUATE VENTILATION. | 4512 N CENTRAL PARK AVE | COMPLAINT | CLOSED | View |
BASEMENT, DISCONTINUE | INSTALLED WITHOUT PERMIT. | 4512 N CENTRAL PARK AVE | COMPLAINT | CLOSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | NO GUARD RAIL GRADE BASEMENT | 4512 N CENTRAL PARK AVE | PERMIT | PASSED | View |
INSPECT CONSTRUCTION WORK | CALL 312-743-1000 TO SCHEDULE INSPECTION. PLANS AND PERMIT MUST BE ON SITE. | 4512 N CENTRAL PARK AVE | PERMIT | PASSED | View |
REPAIR EXTERIOR STAIR | NO HANDRAIL GRADE BASEMENT | 4512 N CENTRAL PARK AVE | PERMIT | PASSED | View |
ARRANGE FOR REINSPECTION REGAR | REAR PORCH SYSTEM SCHEDULE INSPECTION WITH APPROVED PLANS & PERMIT ON SITE FOR FINAL INSPECTION-RECENT NEW PORCH BUILT. | 4512 N CENTRAL PARK AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRONT EAST AT 3RD ABOVE WINDOW FACING SOUTH BULGING & SHIFTING AREA-EAST ABOVE 2ND & NORTH ABOVE 2ND FLOOR WINDOWS OPEN JOINTS SHIFTING BRICKS | 4512 N CENTRAL PARK AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE AT FRONT OF BUILDING BELL SYSTEM FOR INTERIOR INSPECTION TO VERIFY DETECTORS 2008. | 4512 N CENTRAL PARK AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BOARD, BROKEN WINDOW 1ST FL NORTH | 4512 N CENTRAL PARK AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | OPEN MORTAR JOINT REAR UNDER PORCH | 4512 N CENTRAL PARK AVE | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | THROUGHOUT ENTIRE PORCH, - FLOOR AND ROOF PRE- ENGINEER HANGERS ARE SEVERELY RUSTED, SOME ALREADY DESINTEGRATED, OTHERS ARE IN REALLY BAD SHAPE, - UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, ALL STRINGERS - 6X6 BEAMS MISSING STEEL ANGLES OR STEEL STRAPS,-6X6 COLUMNS MISSING ALL STEEL CONNECTIONS TO 6X6 BEAMS, ALL CRITICAL CONNECTIONS ARE ONLY NAIL THROUGHOUT ENTIRE PORCH. PERMIT ONLY TO REAPIR ROOF. | 4512 N CENTRAL PARK AVE | PERIODIC | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | REAR UNDERNEATH PORCH SYSTEM-USED AS STORAGE ALSO LANDINGS 1ST, 2ND & 3RD | 4512 N CENTRAL PARK AVE | PERIODIC | FAILED | View |