Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
NO KEY TO USE EXIT DOOR | NORTH AND SOUTH GATE DOUBLE KEY LOCKS | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATION WALLS SPALLING,WASH-OUT MORTAR (PERMIT REQUIRE) | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | ALL WINDOW SILLS OPEN MORTAR JOINT | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR ROOF | EAST ROOF BY ALLEY,LOOSE SHINGLES | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW | AT 2ND ROTTED FRAME,EAST BASEMENT FRAME | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | BUILDING - ADDRESS NOT POSTED. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY WOOD PORCH: COLUMNS ERECTED ON TOP OF CONCRETE SLAB AND CONCRETE BASE.; FOOTING STATUS UNKNOWN.' RIM JOIST IS FASTENED TO COLUMNS WITH NAILS ONLY.; GUARDRAILS END POST TO WALL, HORIZONTAL TIES AND STRINGERS ARE FASTENED WITH NAILS ONLY.; TREADS ARE ONLY 9-1/2" WIDE.; GUARDRAILS OVER 4'-0" LONG - MISSING INTERMEDIATE SUPPORT AND ARE ONLY 40-1/2" HIGH. PERMIT ONLY REQUIRED FOR PORCH REPAIRS. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR EAVES | EAST ROOF EAVES - PEELING PAINT. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | ALL LEVELS EXIT SIGNS - SEVERAL ARE NOT ILLUMINATED. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | MAIN FRONT INTERIOR STAIRS - SQUEAKY STAIRS. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
CARPETING | MAIN EAST INTERIOR STAIRS 1ST TO 3RD - TORN CARPET.BASEMENT HALLWAY - STAINED CARPET. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR DOOR HARDWARE | FRONT MAIN INTERIOR STAIRWAY 2ND AND 3RD FLOOR DOORS - MISSING SELF-CLOSERS AND ARE PROPPED OPEN | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | FRONT MAIN INTERIOR STAIRWAY, 3RD FLOOR CEILING - PEELING PAINT. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
PARAPET | SOUTH PARAPET - WASHED OUT MORTAR. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED YEARS 1990 THRU 2016. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | UNABLE TO VERIFY DETECTORS,OCCUPANCY,AND CONDITION THRU-OUT,NO ENTRY TO PORCH | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
PARAPET | THROUGHOUT [ESPECIALLY AT SOUTHEAST CORNER] /PARAPET - STEP CRACKS WITH SECTIONS HEAVING AND SEVERELY WASHED OUT AND CRUMBLING MORTAR. PERMITS REQUIRED FOR REPAIRS TO CHIMNEY. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
CHIMNEY | WEST ELEVATION - CHIMNEY /BRICKS - SEVERELY WASHED OUT MORTAR WITH SECTIONS SEVERELY SPELLED. PERMITS REQUIRED FOR MASONRY REPAIRS TO CHIMNEY. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | ALL ELEVATIONS - WINDOWS /SILLS - WASHED OUT JOINTS. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS - AROUND WINDOWS AND DECORATIVE DETAILS/ BRICKS - STEP CRACKS WITH SECTIONS HEAVING AND WASHED OUT AND CRUMBLING MORTAR. PERMITS REQUIRED FOR REPAIRS TO EXTERIOR WALL. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | ALL ELEVATIONS - ALL WINDOWS /LINTELS - WARPED AND RUSTED WITH LARGE GAPS PACKED WITH MORTAR. PERMITS REQUIRED FOR LINTEL REPAIRS. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR FENCE | SOUTH ELEVATION - IRON RENCE /FENCE SECTION - SEVERELY RUSTED OUT. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS - WINDOWS /PANES - MISSING AND BROKEN. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | SOUTH, EAST, NORTH ELEVATIONS - 3RD FL /CORNICE - SECTIONS HEAVING WITH WASHED OUT JOINTS. | 2530 N SACRAMENTO AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS - AROUND WINDOWS AND DECORATIVE DETAILS/ BRICKS - STEP CRACKS WITH SECTIONS HEAVING AND WASHED OUT AND CRUMBLING MORTAR. PERMITS REQUIRED FOR REPAIRS TO EXTERIOR WALL. | 2530 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | ALL ELEVATIONS - ALL WINDOWS /LINTELS - WARPED AND RUSTED WITH LARGE GAPS PACKED WITH MORTAR. PERMITS REQUIRED FOR LINTEL REPAIRS. | 2530 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | SOUTH, EAST, NORTH ELEVATIONS - 3RD FL /CORNICE - SECTIONS HEAVING WITH WASHED OUT JOINTS. | 2530 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
PARAPET | THROUGHOUT [ESPECIALLY AT SOUTHEAST CORNER] /PARAPET - STEP CRACKS WITH SECTIONS HEAVING AND SEVERELY WASHED OUT AND CRUMBLING MORTAR. PERMITS REQUIRED FOR REPAIRS TO PARAPET. | 2530 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
CHIMNEY | WEST ELEVATION - CHIMNEY /BRICKS - SEVERELY WASHED OUT MORTAR WITH SECTIONS SEVERELY SPALLED. PERMITS REQUIRED FOR MASONRY REPAIRS TO CHIMNEY. | 2530 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS - WINDOWS /PANES - MISSING AND BROKEN. | 2530 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | SOUTH ELEVATION - IRON FENCE /FENCE SECTION - SEVERELY RUSTED OUT. | 2530 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | ALL ELEVATIONS - WINDOWS /SILLS - WASHED OUT JOINTS. | 2530 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION - 4-STORY WOODEN PORCH /COLUMNS - 6"X6" SITTING ON CONCRETE WALK AND CONCRETE BLOCKS WITH UNKNOWN DEPTH AND DETERIORATING BASES; HALF LAP SPLICES 1' ONLY WITH TWO BOLTS; BOWING AT TOP CONNECTION. /BEAMS - CRACKING AT CONNECTIONS AND UNDER LANDINGS. /RAILS - DETERIORATING CONNECTIONS WITH CRACKS AND CHIPPING SECTIONS. /STRINGERS - CRACKED WITH SECTIONS MISSING; SECURED WITH SCREWS AND NAILS ONLY. /STAIRS - SECTIONS BOWING, LOOSE, AND OUT OF PLUMB. /ROOF - CRACKED BEAM AND SHIFTED DOWNWARD. /DECKING - WARPED, LOOSE, AND LIFTED. /HARDWARE - RUSTED AND PULLING. /WOOD - CRACKING AND WEATHERED WITH PEELING AND FLAKING PAINT. PLANS AND PERMITS REQUIRED FOR REPAIRS AND REPLACEMENT OF PORCH SYSTEM. | 2530 N SACRAMENTO AVE | COMPLAINT | FAILED | View |