The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; | 5435 S WINCHESTER AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING ¿ 1ST. FL. - ENTRY REFUSED; 2ND. FL. - NO RESPONSE; UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY;UNABLE TO INSPECT INTERIOR STAIRWAY; REAR YARD - LARGE DOG; UNABLE TO INSPECT REAR PORCH; | 5435 S WINCHESTER AVE | COMPLAINT | CLOSED | View |
REPAIR SCREENS | FRONT AND NORTH ELEVATION /WINDOW SCREENS - RIPPED, MISSING;NOTE: LARGE DOG IN REAR YARD - UNABLE TO INSPECT REAR AND SOUTH ELEVATION; | 5435 S WINCHESTER AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT AND NORTH ELEVATION /WINDOWS - BROKEN PANES;NOTE: LARGE DOG IN REAR YARD - UNABLE TO INSPECT REAR AND SOUTH ELEVATION; | 5435 S WINCHESTER AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION /1 STORY WOOD PORCH; 4 FEET X 6 FEET 8 INCHES;FOUNDATIONS /BASES FORMED BY CONCRETE POURED IN AROUND COLUMN; FOUNDATION STATUS UNKNOWN;LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS ONLY; DECK JOISTS /HEADERS AND RIM JOISTS FASTENED TO COLUMNS, WITH NAILS/SCREWS ONLY; DECK JOIST /HANGERS - GAPS;STRINGERS /UPPER ENDS OF [CENTER] STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS, FASTENED WITH NAILS /SCREWS ONLY; UNDERSIZED HARDWARE USED AT COLUMNS; STRINGER /UNDERSIZED 2X10; STAIRS /RISER HEIGHT NOT UNIFORMED, RANGING FROM 10 INCHES TO 7 INCHES TO 6 3/4 INCHES TO 9 1/4 INCHES; TREADS - ONLY 9 1/4 INCHES, [TREAD HELD BACK 3/4 INCH FROM 1X RISER] NOSING - MISSING; RAILINGS /GUARD RAILING SECTIONS ONLY 38 INCHES HIGH - ALL RAILING SECTIONS FASTENED TO EXTERIOR WALL WITH NAILS /SCREWS ONLY; | 5435 S WINCHESTER AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | FRONT AND NORTH ELEVATION /WINDOW FRAMES - ROTTED; | 5435 S WINCHESTER AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW SASH | FRONT AND NORTH ELEVATION /WINDOW SASHES - ROTTED; | 5435 S WINCHESTER AVE | COMPLAINT | CLOSED | View |
REPAIR EAVES | FRONT AND NORTH ELEVATION /EAVES - ROTTED; | 5435 S WINCHESTER AVE | COMPLAINT | CLOSED | View |
REPAIR GUTTER | NORTH AND SOUTH ELEVATION /GUTTERS - DEBRIS; | 5435 S WINCHESTER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION /1 STORY WOOD PORCH; 4 FEET X 6 FEET 8 INCHES;FOUNDATIONS /BASES FORMED BY CONCRETE POURED IN AROUND COLUMN; FOUNDATION STATUS UNKNOWN;LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS ONLY; DECK JOISTS /HEADERS AND RIM JOISTS FASTENED TO COLUMNS, WITH NAILS/SCREWS ONLY; DECK JOIST /HANGERS - GAPS;STRINGERS /UPPER ENDS OF [CENTER] STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS, FASTENED WITH NAILS /SCREWS ONLY; UNDERSIZED HARDWARE USED AT COLUMNS; STRINGER /UNDERSIZED 2X10; STAIRS /RISER HEIGHT NOT UNIFORMED, RANGING FROM 10 INCHES TO 7 INCHES TO 6 3/4 INCHES TO 9 1/4 INCHES; TREADS - ONLY 9 1/4 INCHES, [TREAD HELD BACK 3/4 INCH FROM 1X RISER] NOSING - MISSING; RAILINGS /GUARD RAILING SECTIONS ONLY 38 INCHES HIGH - ALL RAILING SECTIONS FASTENED TO EXTERIOR WALL WITH NAILS /SCREWS ONLY; | 5435 S WINCHESTER AVE | COMPLAINT | CLOSED | View |
REPAIR GUTTER | NORTH AND SOUTH ELEVATION /GUTTERS - DEBRIS; | 5435 S WINCHESTER AVE | COMPLAINT | CLOSED | View |
PROVID SELF CLSING SCREEN DVCE | FRONT ELEVATION /MTAL SCREEN DOORS X2 - RUSTED; | 5435 S WINCHESTER AVE | COMPLAINT | CLOSED | View |