Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FILE BLDG REGISTRATION | NOT REGISTERED 2000-2012 | 7550 S EGGLESTON AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 COLUMNS STACKED AND TOENAILED; 2X8 JOISTS SPAN 8'-10"; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; JOIST HANGERS MISSING; HANDRAIL MISSING FROM GRADE TO BASEMENT; BURGLAR BARS ON 1ST FLOOR OBSTRUCTING EXITWAY, HENCE, UNABLE TO COMPLETE PORCH INSPECTION. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 7550 S EGGLESTON AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR PORCH - BURGLAR BARS ON 1ST FLOOR DECK OBSTRUCTING EXITWAY | 7550 S EGGLESTON AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICEWALK - CRACKED | 7550 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - (WEST) - ROTTING WOOD SIDING; (NORTH) - ALUMINUM SIDING MISSING | 7550 S EGGLESTON AVE | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | LUMBER, MATERIALS, JUNK STORED UNDERNEATH REAR STAIRS/PORCH. | 7550 S EGGLESTON AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY - WASHED OUT MORTAR | 7550 S EGGLESTON AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, APARTMENTS, STAIRWELL, BASEMENT, BALCONIES, AND ENTIRE REAR PORCH. UNVERIFIED DETECTORS AND OCCUPANCY. | 7550 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 COLUMNS STACKED AND TOENAILED; 2X8 JOISTS SPAN 8'-10"; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; JOIST HANGERS MISSING; HANDRAIL MISSING FROM GRADE TO BASEMENT; BURGLAR BARS ON 1ST FLOOR OBSTRUCTING EXITWAY, HENCE, UNABLE TO COMPLETE PORCH INSPECTION. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 7550 S EGGLESTON AVE | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR PORCH - BURGLAR BARS ON 1ST FLOOR DECK OBSTRUCTING EXITWAY | 7550 S EGGLESTON AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICEWALK - CRACKED | 7550 S EGGLESTON AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - (WEST) - ROTTING WOOD SIDING; (NORTH) - ALUMINUM SIDING MISSING | 7550 S EGGLESTON AVE | COMPLAINT | PASSED | View |
NO CLOSET/STORAGE UNDER STAIR | LUMBER, MATERIALS, JUNK STORED UNDERNEATH REAR STAIRS/PORCH. | 7550 S EGGLESTON AVE | COMPLAINT | PASSED | View |
CHIMNEY | CHIMNEY - WASHED OUT MORTAR | 7550 S EGGLESTON AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, APARTMENTS, STAIRWELL, BASEMENT, BALCONIES, AND ENTIRE REAR PORCH. UNVERIFIED DETECTORS AND OCCUPANCY. | 7550 S EGGLESTON AVE | COMPLAINT | PASSED | View |