The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEBRIS, EXCESSIVE | EMPTY DRUG BAGGIES IN YARD | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERS I.D. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WATER DAMAGED BRICKWORK WEST ABOVE BALCONY, OPEN MORTAR JOINTS AND BELLIED WING WALL NEAR FRONT DOOR | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | WEST GUTTER LEAKS | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
REPAIR FENCE | MISSING SECTIONS OF TOP RAIL WEST CHAIN LINK FENCE | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR AT BASEMENT | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR TWO STORY FRAME PORCH: IMPROPER LOOKOUT TO UPRIGHT CONNECTION OVERSPANNED FLOOR JOIST, UNDERSIZED GUARDRAILS ONE WEAKER TREAD GRADE TO 1ST FLOOR | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | MISSING HANDRAIL BASEMENT TO GRADE EAST | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | REMOVE OBSTRUCTION FROM KITCHEN SINK | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THRU OUT 1ST FLOOR UNITS AND OTHER TYPICAL UNITS IN BUILDING | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR ARMORED CABLE THRU OUT BASEMENT AREAS, AND LITE BY WATER METER IN BASEMENT | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LITE FIXTURES THRU OUT 1ST FLOOR UNIT AND OTHER TYPICAL UNITS IN BUILDING | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | PROVIDE ILLUMINATION FOR GARAGE ENTRANCE DOOR AREAS | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
ARMORED CABLE | REPLACE DEFECTIVE ARMORED CABLE THRU OUT BASEMENT AREAS | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
GROUNDING RECEPTACLES | PROVIDE GROUNDING TYPE RECEPTACLES FOR ALL BASEMENT, 2 FLOOR AREAS | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, ASEMENTS AREAS, GARAGE - 18-27-210.25 | 7829 S PEORIA ST | COMPLAINT | FAILED | View | |
REPAIR**************** | REPLACE DEFECTIVE WIRING THRU OUT BASEMENT AREAS 1ST FLOOR UNIT AND OTHER TYPICAL UNIT IN BUILDING - 18-27-110.7 | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
INSTALL VENT PIPE FOR TRAP | BASEMENT - LAUNDRY TUB - REMOVE S TRAP AND RUBBER COUPLING ON THE WASTE ARM. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR TWO STORY EXTERIOR WOODEN PORCH RECENTLY REPAIRED. FIRST AND SECOND FLOOR DECKS, 2X8 JOISTS UNDERSIZED AND SPAN 14 FEET. RIM JOISTS NOT PROPERLY PLACED TO SUPPORT DECKING. SOUTHEAST 6X6 COLUMN NOTCH FOR RIM JOISTS OVERCUT, NO PROPER BEARING TO RIM JOISTS. GRADE TO FIRST, TREADS NO NOSING. 6X6 COLUMNS - FOUNDATIONS STATUS UNKNOWN. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR EXTERIOR CONCRETE STAIRWELL, GRADE TO BASEMENT, GUARD RAIL MISSING ALONG WITH STAIR RAIL. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT FOR ALL RELATED REPAIRS TO REAR TWO STORY EXTERIOR WOODEN PORCH. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT/SLEEPING QUARTERS, NO SMOKE DETECTOR. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | SECOND FLOOR - FLEXIBLE WATER SUPPLIES ON LAVATORY, TOILET AND KITCHEN SINK. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | SECOND FLOOR - BATH TUB, FAUCET HANDLE FLANGE TOO FAR FROM WALL. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | FIRST FLOOR - WASHER WATER LINE REQUIRE AIR CHAMBERS ON THE HOT AND COLD LINES. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | FIRST FLOOR - KITCHEN SINK - REMOVE FLEXIBLE WASTE PIPE AND INSTALL RIGID TUBING. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | FIRST FLOOR KITCHEN SINK - REMOVE FLEXIBLE WATER SUPPLIES AND INSTALL COPPER TUBE SUPPLIES. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | BASEMENT - REMOVE FLEXIBLE WATER SUPPLIES AND INSTALL COPPER TUBE SUPPLIES. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
WORKING SPACE | PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANEL - COVERS OVERLAP ONE ANOTHER. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
INSTALL COVERS | PROVIDE GARVIN TYPE COVERS FOR SWITCHES AND BOXES THROUGHOUT BASEMENT AREAS. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | REMOVE ALL ABANDONED RACEWAY, BOXES, CABLE, AND ELECTRICAL EQUIPMENT - REMOVE OLD WATER MAIN GROUND IN BASEMENT AREAS. 18-27-110.12E. | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS. 13-12-360. | 7829 S PEORIA ST | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTER TYPE AREAS, BATHROOM, LAUNDRY AREAS IN BASEMENT, 1, 2 FLOOR UNITS - 18-27-210.8 | 7829 S PEORIA ST | COMPLAINT | FAILED | View |
PROVIDE WEATHERPROOF BOXES, LITES, AND FITTINGS FOR REAR EXTERIOR PORCH AREAS - 18-27-110.11 | 7829 S PEORIA ST | COMPLAINT | FAILED | View |