Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 2:20 PM
PIN: 20322290330000
Property Address: 8254 S GREEN ST
City - Zip: CHICAGO - 60620
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72222
2023 Tax District: 72001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 22 Violations
Violation Inspector Comments Address Category Status View
CARB MONOX DETECT IN RESID BASEMENT / CARBON MONOXIDE DETECTOR - MISSING. 8254 S GREEN ST COMPLAINT FAILED View
CARPETING FRONT INTERIOR STAIRWAY CARPETING LOOSE AND SEPERATED FROM TREADS ( FALL HAZARD ). 8254 S GREEN ST COMPLAINT FAILED View
REPAIR LINTELS EAST ELEVATION / LINTELS - RUSTED AND SAGGING CAUSING SPALLED CORNERS. PLANS AND PERMIT REQUIRED FOR LINTEL REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. 8254 S GREEN ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST ELEVATION / 2 STORY PARTIALLY ENCLOSED WOOD PORCH / COLUMNS FOR ENCLOSED PORTION OF PORCH - ERECTED ON CONCRETE BLOCKS. FOUNDATION STATUS - UNKNOWN. SOUTH COLUMN - STACKED UPON ANOTHER. 4X4 COLUMN ERECTED ON BASEMENT FOUNDATION THAT IS CRACKED WITH NISSING CONCRETE. BOTTOMS - ROTTING AND DETERIORATED. NORTHERN COLUMN ERECTED ON A FRACTURED CONCRETE BLOCK. STAIR SYSTEM IS SUPPORTED BY AN OVERSPANNED 2X8 JOIST. 4X4 COLUMN - NOTCHED AT SINGLE 2X8 END BEAM. 4X4 COLUMN HALF LAP JOINT - FASTENED NAILS ONLY. ENTIRE DECK STRUCTURE - SAGGING OUT OF LEVEL. SRTRINGERS - ROTTING AND CRACKING. UPPER ENDS OFSTRINGERS - FASTENED WITH NAILS ONLY. STRINGERS - FASTENED TO COLUMNS WITH NAILS ONLY. BOTTOM OF STRINGERS - PULLING AWAY FROM DECK STRUCTURE. JOISTS - FASTENED WITH NAILS ONLY. ALL RAILINGS - FASTENED WITH NAILS ONLY. EXTERIOR WALLS ON ENCLOSED PORCH - ROTTING AND DETERIORATED SIDING.PLANS AND PERMIT REQUIRED TO REPLACE REAR 2 STORY PORCH STRUCTURE. 8254 S GREEN ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST, SOUTH AND WEST ELEVATIONS / EXTERIOR WALL AT EAST - MASONRY FRACTURES WITH WASHED OUT MORTAR. SOUTH EXTERIOR WALL - WASHED OUT MORTAR. REAR MASONRY GARAGE NORTH EXTERIOR WALL - MASONRY FRACTURES. PERMIT REAQUIRED FOR ALL MASONRY REPAIRS. WEST AT ENCLOSED PORCH / SIDED WALLS - LOOSE AND MISSING WITH HOLES. 8254 S GREEN ST COMPLAINT FAILED View
MAINTAIN WINDOW WEST AT ENCLOSED PORCH / WINDOW FRAMES - ROTTING AND DETERIORATED WITH HOLES. 8254 S GREEN ST COMPLAINT FAILED View
MICE/RODENTS BUILDING THROUGHOUT - INFESTED WITH MICE. MICE - OBSERVED AT BASEMENT AND 2ND FLOOR APT. 8254 S GREEN ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR BASEMENT HAS BEEN CONVERTED INTO AN APT. SUBMIT PLANS AND OBTAIN PERMIT TO AUTHORIZE ALTERATIONS TO THE BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 8254 S GREEN ST COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES INCLUDING ELECTRICAL AND PLUMBING INSTALLED IN THE BASEMENT WITHOUT A PERMIT. 8254 S GREEN ST COMPLAINT FAILED View
PARAPET EAST ELEVATION / PARPET - MASONRY FRACTURES WITH WASHED OUT MORTAR. 8254 S GREEN ST COMPLAINT FAILED View
REPAIR CORNICE EAST ELEVATION / CORNICE - FRACTURED, SEPERATING WITH WASHED OUT MORATAR. PERMIT REQUIRED FOR ALL MASONRY REPAIRS. 8254 S GREEN ST COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION WEST ELEVATION AT BASEMENT STAIRS / FOUNDATION WALL - CRACKED AND MISSING CONCRETE. 8254 S GREEN ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR WEST BASEMENT STAIRS - MISSING HANDRAIL. 8254 S GREEN ST COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT BASEMENT STAIRS - CRACKED TREAD. HANDRAILS CONSIST OF PVC PIPES ( FLIMSY ). 8254 S GREEN ST COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE BASEMENT HAS A NON VENTED GAS HEATER INSTALLED. CB046013 - UNAPPROVED HEATING DEVICE ( 14X-8-802.2) 8254 S GREEN ST COMPLAINT FAILED View
HEATING PLANT SEPARATION BASEMENT / BOILER ROOM - MISSING DRYWALL AT WALLS AND CEILING. 8254 S GREEN ST COMPLAINT FAILED View
SAFE WORKING CONDITIONS BOILER OUT OF SERVICE. 8254 S GREEN ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR. 8254 S GREEN ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTOR. 8254 S GREEN ST COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE USING STOVE AS HEATING DEVICE. 8254 S GREEN ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS INTERIOR STAIRWAY AND APT 2 / SMOKE DETECTORS - MISSING. 8254 S GREEN ST COMPLAINT FAILED View
STOP LEAKING WATER BASEMENT - LEAKING WATER AT REAR. FLOOR'S CARPETING - STAURATED AT TIME OF INSPECTION. 8254 S GREEN ST COMPLAINT FAILED View