Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSTALL COVERS | THROUGHOUT BASEMENT 18-27-370.25 | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | THROUGHOUT BASEMENT 18-27-110.12 | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | WEAK FLOORS 1ST & 2ND FLOORS. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | GAPS AT FRONT EXTERIOR DOOR. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | NO DEAD BOLT REAR KITCHEN DOOR. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | DOOR FRAMING MISSING AT REAR EXTERIOR DOOR. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | BROKEN FLOOR JOIST AT BASEMENT OVER FURNACE. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSED WIRES & HANGING CONDUIT AT BASEMENT. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | WALLS FORMING ROOMS AT BASEMENT. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | TOLIET SHOWER & SINK AT BASEMENT. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
REPAIR DOOR FRAME, MULLION | 2ND FLOOR INTERIOR DOORS TOO SMALL FOR OPENINGS. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRS BASEMENT TO 2ND FLOOR WEAK TREADS LOOSE HANDRAILS. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW PANES 2ND FLOOR NORTH AT STAIRS & 1ST FLOOR AT KITCHEN. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | KITCHEN FLOOR BROKEN TILES & GAPS AT TILES. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | NO WINDOW EASING AT FRONT WINDOWS. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | MISSING SIDING FRONT & BOLGING SIDING SOUTH. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | DEFECTIVE DOOR HARD WARE FRONT EXTERIOR DOOR. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT STAIRS NO FOOTING, OVER CUT STRINGERS, WEAK DECKING , NO JOIST HANGERS, PICKETS SPACED OVER 4 INCHES, NO LEDGER BOLTS REAR STAIRS- NO JOIST HANGERS, NO LEDGER BOLTS, NO FOOTING, PICKET SPACING OVER 4INCHES, MISSING HAND & GUARD RAILS AT BASEMENT STEPS GUARD RAILS UNDER 42" HANDRAILS UNDER 34"INCHES. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | DEBRIS AT REAR YARD. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMITS NEEDED FOR REPAIR NO PLAN NEEDED FOR PERMITS. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | EMPLOY LICENSE PLUMBER (18-29-106.1-106.2) | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FOR INSPECTION (13-12-100) | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
RMV WATER,SOIL,WASTE,VENT | REMOVE ROUGHED IN PLUMBING (13-12-050,13-32-010) | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
PROPER SIXE SOIL/WASTE PIPE | INSTALL PROPER SIZE PIPE (18-29-710) | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 7012) 18-28-801 CHIMNEY AND VENTS | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 18-28-106.1 INSPECTION REQUIRED ARRANGE FOR COMPETE PERMIT INSPECTIONS AND OBTAIN PERMITS FOR WARM AIR HEATING SYSTEMS AND VENTILATION SYSTEMS WHEN WORK IS COMPLETED | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 711) 18-28-711 CARBON MONOXIDE DETECTORS | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE SMOKE DETECTORS INSTALL EVERY ROOM WITH GAS APPLIANCE | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | 18-28-403.2 STRUCTURAL REQUIREMENTS OF A MECHANICAL SYSTEM-SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ARTICLE 6, DUCT SYSTEMS | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 7036) 18-13-803-2-3.1-TEMPERATURE CONTROLS EACH HEATING AND COOLING SYSTEM SHALL HAVE AT LEAST ONE SOLID STATE PROGRAMMABLE THERMOSTAT | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
MAINTAIN MECH. VENT SYSTEM | 18-28-102 APPLICABILITY MAINTAIN MECHANICAL VENTILATION EQUIPMENT IN GOOD REPAIR AND OPERATE TO PROVIDE ADEQUATE VENTILATION DURING HOURS OF OCCUPANCY | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
MAINTAN BLDG IN SAFE CONDITION | 8038 S NORMAL AVE | COMPLAINT | CLOSED | View | |
SUBMIT FOR APPROVAL PLANS | 8038 S NORMAL AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 8038 S NORMAL AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 8038 S NORMAL AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 8038 S NORMAL AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 8038 S NORMAL AVE | COMPLAINT | CLOSED | View | |
STOP/REMOVE NUISANCE | INOPERATIVE VEHICLE AT REAR YARD. | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |
POST OWNER NAME OF VACNT BLDG | VIOLATION CLOSED PER PCR 1180 | 8038 S NORMAL AVE | COMPLAINT | CLOSED | View |
OPEN | 8038 S NORMAL AVE | PERMIT | PASSED | View | |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PERMIT 918-29-106.1) | 8038 S NORMAL AVE | COMPLAINT | FAILED | View |