Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CONTRARY TO PLANS/OUT OF SCOPE | PERFORMED OR ALLOWED CONSTRUCTION OR ALTERATION WORK CONTRARY TO OR EXCEEDING THE SCOPE OF APPROVED PLANS AND PERMIT:ERECTING NEW WOOD 2 STORY PORCH ON EXISTING RETAINING WALLS.ELIMINATING FOOTINGS AND FOUNDATION PIERS SHOWN ON APPROVED PLANS. | 4122 W NEWPORT AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REVISE PLANS TO SHOW AS BUILT REAR PORCH ON EXISTING RETAINING WALLS OR BUILD ACCORDING TO APPROVED PLANS. | 4122 W NEWPORT AVE | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. | 4122 W NEWPORT AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH ELEVATION, WOOD WINDOW FRAMES PEELING PAINT. | 4122 W NEWPORT AVE | COMPLAINT | FAILED | View |
CHIMNEY | WEST ELEVATION, CHIMNEY - LARGE CRACKES WITH WASHED OUT MORTAR JOINTS. | 4122 W NEWPORT AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR, FRONT INTERIOR STAIRS - MISSING SMOKE DETECTOR. | 4122 W NEWPORT AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | NORTH ELEVATION, NORTH EXTERIOR 2 STORY + ATTIC WOOD PORCH SYSTEM. 4X6 COLMUNS ON CRACKED CONCRETE BLOCKS,4X4 COLUMNS ON TOP OF CONCRETE SLAB - FOUNDATIONS UNKNOWN. 4X6 WOOD COLUMNS SEVERELY ROTTON AT BASE. COLUMNS UNDERSIZED. ALL RIM JOISTS TO COLUMN CONNECTIONS SEVERELY ROTTING WITH GAPS, JOIST PULLING AWAY FROM COLUMNS. STRINGERS AT GROUND TO 1ST FLOOR SEVERELY ROTTEN AND NO LONGER SUPPORTED AT BASE, TREADS AND RISERS LOOSE AND ROTTING. ALL STRINGERS FACE NAILED ONLY AND MISSING BOLTED CONNECTIONS. 1ST AND 2ND FLOOR DECK BOARDS SEVERELY ROTTING AND BUCKLING. SINGLE 2X8 BEAMS UNDERSIZED TO SUPPORT DECK JOIST. ALL DECK JOISTS UNDERSIZED AND MISSING JOISTS HANGERS. DECK JOISTS PULLING FROM RIM JOISTS. LANDING TO ATTIC JOISTS ONLY 2X4S - UNDERSIZED. ALL RAILINGS SEVERELY ROTTING, SEVERELY LOOSE AND MISSING MULTIPLE PICKETS. RAILINGS ONLY 28 INCHES HIGH. 2ND FLOOR RAILINGS NO LONGER CONNECTED AND BEING HELD BY BUNGEE CORDS. ATTIC ACCESS OBSTRUCTED BY STORAGE ITEMS. ENTIRE PORCH DANGEROUS AND HAZARDOUS - PLANS AND PERMIT REQUIRED TO REPLACE PORCH SYSTEM. | 4122 W NEWPORT AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION, GROUND FLOOR - STONE KNEE WALL SHIFTING AT FRONT ENTRY. | 4122 W NEWPORT AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | WEST ELEVATION, ROOF EAVES - MISSING SECTIONS OF SOFFIT FINISH MATERIAL. NORTH ELEVATION, GARAGE ROOF EAVES ROTTING. | 4122 W NEWPORT AVE | COMPLAINT | FAILED | View |