Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | GRADE TO BASEMENT AND 1ST FLOOR TO 2ND FLOOR MISSING HANDRAIL. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | COMMON STAIRWELL, BASEMENT, 2ND FLOOR MISSING SMOKE DETECTORS. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT, 2ND FLOOR MISSING CARBON MONOXIDE DETECTORS. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | CHAIN LINK FENCE AT REAR IN EXCESS OF 5 FT. IN HEIGHT. REMOVE, REDUCE HEIGHT OR OBTAIN PERMIT. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE 4" PVC FOR CLEAN OUT DRIVEWAY EAST ELEVATION. PROVIDE PROPER MATERIAL. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES ON WATER HEATER EAST ELEVATION BASEMENT, LAVATORY, TOILET 2ND FLOOR RESTROOM. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
(18-27-210.8) INSTALL GFCI'S TO WET LOCATIONS. | 1711 W 85TH ST | COMPLAINT | FAILED | View | |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES ON EXTERIOR AND INTERIOR. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REPAIR EAVES | FLAKEY PAINT NORTH FACCIA BOARD, ROTTED FACCIA EAST | 1711 W 85TH ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | LEAKY GUTTERS NORTH | 1711 W 85TH ST | COMPLAINT | FAILED | View |
MAINTAIN PROJECTIONS | OPEN MORTAR JOINT 2ND FLOOR STONE SILL NORTH | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | MISSING PANES AT BASEMENT EAST. CRACKED WINDOW PANE 1ST FLOOR EAST. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | ROTTED VENEER AT BASE OF SOUTH ENTRANCE DOOR AT GRADE | 1711 W 85TH ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES ON EXTERIOR | 1711 W 85TH ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INTALL ILLUMINATION TO GARAGE ENTRY DOOR | 1711 W 85TH ST | COMPLAINT | FAILED | View |
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. | 1711 W 85TH ST | COMPLAINT | FAILED | View | |
ARRANGE COMPLETED PERMIT INSP. | 1711 W 85TH ST | PERMIT | FAILED | View | |
REPAIR EXTERIOR DOOR HARDWARE | NORTH ENTRY DOOR MISSING HANDLE | 1711 W 85TH ST | COMPLAINT | FAILED | View |
PRV BALLCOCK,VB,OR AIR GAP | SILCOCK NORTHEAST AND SOUTHEAST ELEVATION | 1711 W 85TH ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO REAR EXTERIOR ENTRY DOORS INCLUDING GARAGE ENTRY DOOR | 1711 W 85TH ST | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE POWER SERVICES INSTALL MINIMUM 200 AMP IN SINGLE ENCLOSURE. INSTALL PUBLIC METER AND PANEL. PROVIDE PERMIT TO CORRECT VIOLATIONS | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | BROKEN FLOOR TILES ON FIRST AND SECOND FLOORS | 1711 W 85TH ST | COMPLAINT | FAILED | View |
PROVIDE A WATER MAIN GROUND CONDUIT, CONDUCTOR TO WITHIN FIVE FEET OF WATER METER OR VALVE 14E-2-250.68 C-1 | 1711 W 85TH ST | COMPLAINT | FAILED | View | |
REPLACE DEFECTIVE TOILET SEAT | REPLACE BROKEN TOILET SEAT IN THE BASEMENT | 1711 W 85TH ST | COMPLAINT | FAILED | View |
CIRCUIT 1 UNIT ONLY | PROVIDE A PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREAS, AND GARAGE | 1711 W 85TH ST | COMPLAINT | FAILED | View |
PRV RELIEF VALVE HOTWATER HTR | INSTALL A RELIEF VALVE ON THE BOILER IN THE BASEMENT, THE EXISTING VALVE WAS PUT ON BACKWARDS, DANGEROUS AND HAZARDOUS | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REPAIR DOOR HARDWARE | IMPROPER DOOR HARDWARE FOR BEDROOMS OF FIRST AND SECOND FLOORS | 1711 W 85TH ST | COMPLAINT | FAILED | View |
PROVIDE AN ELECTRICAL PERMIT TO CORRECT ELECTRICAL VIOLATIONS 13-12-360 | 1711 W 85TH ST | COMPLAINT | FAILED | View | |
REPLACE DEFECTIVE WATER PIPING | INSTALL AIR CHAMBERS ON THE LAUNDRY TUB FAUCET PIPING IN THE BASEMENT | 1711 W 85TH ST | COMPLAINT | FAILED | View |
INDIRECT CONN.FOR WATER SUPPLY | INSTALL A BACK-FLOW PREVENTER ON THE WATER SUPPLY TO THE BOILER IN THE BASEMENT DANGEROUS AND HAZARDOUS | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | BROKEN AND DAMAGED DOORS IN FIRST AND SECOND FLOORS | 1711 W 85TH ST | COMPLAINT | FAILED | View |
INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT THE BASEMENT AREA WITHOUT ROUGH INSPECTION; ROUGH INSPECTION REQUIRES THAT ALL WALLS AND CEILINGS BE OPENED 13-12-380 | 1711 W 85TH ST | COMPLAINT | FAILED | View | |
REPLACE DEFECTIVE FAUCET | TUB FAUCET MISSING HANDLE | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | BASEMENT KITCHEN SINK STACK LEAKING AT THE CONNECTION AT THE WALL | 1711 W 85TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BEEPING SMOKE DETECTORS IN FIRST AND SECOND FLOORS DANGEROUS AND HAZARDOUS | 1711 W 85TH ST | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REPLACE ALL FIRST FLOOR FLEX WATER SUPPLIES TO ALL FIXTURES WITH COPPER SUPPLIES | 1711 W 85TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NO CARBON MONOXIDE DETECTOR OBSERVED IN BASEMENT, FIRST FLOOR, AND SECOND FLOOR, DANGEROUS AND HAZARDOUS | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | MISSING DOOR HARDWARE FOR FIRST FLOOR FRONT ENTRANCE DOOR | 1711 W 85TH ST | COMPLAINT | FAILED | View |
NO PERMIT WIRING | PBTAIN AN ELECTRICL PERMIT AND ELECTRICAL CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED THROUGH THE BASEMENT, 1ST FLOOR, AND 2ND FLOOR, WITHOUT PLANS AND PERMITS. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
PROVIDE HOT WATER TO FIXTURES | NO WATER AT LAVATORY IN FIRST FLOOR | 1711 W 85TH ST | COMPLAINT | FAILED | View |
PRV DISCHARGE PIPE FROM PRV | INSTALL A METAL PIPE FOR THE RELIEF VALVE IN THE BASEMENT | 1711 W 85TH ST | COMPLAINT | FAILED | View |
HEATING PLANT SEPARATION | NO FIRE SEPARATION IN HEATING PLANT AREA, IN BASEMENT AREA DANGEROUS AND HAZARDOUS | 1711 W 85TH ST | COMPLAINT | FAILED | View |
INSTALL COVERS | MISSING COVERS THROUGHOUT THE BASEMENT, FIRST FLOOR AND SECOND FLOOR AREAS. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR. LARGE DOG IN YARD | 1711 W 85TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER POSTING | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH RUSTED HAND & GUARDRAIL | 1711 W 85TH ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | CHAIN LINK FENCE AT REAR IN EXCESS OF 5' IN HEIGHT REMOVE OR REDUCE HEIGHT OR OBTAIN PERMIT | 1711 W 85TH ST | COMPLAINT | FAILED | View |
18.27.210.8 INTALL GFCI TO REAR EXTERIOR OF BLDG | 1711 W 85TH ST | COMPLAINT | FAILED | View | |
ARRANGE PREMISE INSPECTION | ENTRY REFUSED | 1711 W 85TH ST | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 1711 W 85TH ST | COMPLAINT | FAILED | View |
REMOVE | STORED GAS LAWN MOWER AND SNOW BLOWER. (15-24-090) | 1711 W 85TH ST | COMPLAINT | FAILED | View |