Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR WINDOW SILLS | EXTERIOR FRONT WINDOW SILLS WASHED OUT MORTAR JOINTS. REAR ALL WINDOW SILLS ROTTED. | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | EXTERIOR FRONT AND EAST LINTELS RUSTED AND SAGGING, PROVIDE PLANS AND PERMIT. | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | EXTERIOR FRONT CORNICE WASHED OUT MORTAR JOINTS. | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING MISSING OWNERSHIP INFORMATION. | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS FRONT AND EAST VARIOUS LOCATION SEVERE STRESS FRACTURES AT MORTAR JOINTS, REAR ENCLOSED REAR PORCH WALLS ROTTED. PERMIT REQUIRED. | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EXTERIOR REAR DOOR ROTTED. | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | EXTERIOR WEST PLATFORM WOOD DECK AT 2ND AND 3RD LEVEL. FOUNDATION NOT VERIFIED; COLUMN 6X6 12" LAP JOINTS WITH 2 BOLTS AND NAILED CONNECTIONS; LEDGERS NAILED CONNECTIONS; BEAM TO COLUMN CONNECTIONS NAILED WITH LIGHT GAGE METAL PATCH, STAIR EXITS NOT VERIFIED. PLANS AND PERMIT ARE REQUIRED. | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
CHIMNEY | EXTERIOR WEST CHIMNEY WASHED OUT MORTAR JOINTS. | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | PROVIDE EVIDENCE OF BUILDING REGISTRATION FOR YEARS 1990-2011. | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR ENCLOSED 3 STORY PORCH/COLUMNS-BUTT JOINED WITH NAILS ONLY STAIR HEADER BEAMS-ROTTING WEAK SAGGING WITH SCABBED SECTIONS STRINGERS-SCABBED SECTIONS DECK JOISTS ROTTING,WEAK SAGGING WITH SCABBED SECTIONS ROOF RAFTERS ROTTING WEAK AND SAGGING ALL ENCLOSURE FRAMING ROTTING WEAK AND SAGGING PLANS AND PERMIT REQUIRED TO REPLACE REAR ENCLOSED 3 STORY PORCH | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION/EXTERIOR STAIRWAY FROM 3RD FLOOR REAR APARTMENT TO 2ND FLOOR ENTRY AT REAR ENCLOSED PORCH ONLY 30 TO 32 INCHES WIDE | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | 3RD FLOOR REAR APARTMENT REAR EGRESS-EXTERIOR STAIRWAY LEADS TO REAR ENCLOSED PORCH AT 2ND LEVEL | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | BUILDING/WINDOWS THROUGHOUT-TORN AND MISSING SCREENS | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY, BASEMENT BOILER ROOM,AND APARTMENT 3F-MISSING SMOKE DETECTORS | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT BOILER ROOM AND APARTMENT 3F-MISSING CARBON MONOXIDE DETECTORS | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | APARTMENT 3R/BEDROOM CEILING AND WALLS-SPALLING PLASTER PEELING PAINT WITH MILDEW BUILDUP | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | APARTMENT 3R/BATHTUB-PEELING AND WORN FINISH | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | BASEMENT BOILER ROOM/ELECTRICAL BOXES-MISSING COVERS WITH EXPOSED WIRING | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC0 INSTALLED ON 2ND AND 3RD FLOORS AND BASEMENT | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO 2ND AND 3RD FLOORS AND BASEMENT | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THROUGH 2015 | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | EXTERIOR REAR ALL WINDOWS ROTTED. | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | 3RD FLOOR REAR APARTMENT EXTERIOR EXIT DOOR-ONLY 27 1/4 INCHES WIDE | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | REAR ENCLOSED PORCH-ROOF LEAKING | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 2ND FLOOR FRONT APARTMENT-ONLY ONE EGRESS (IN THE FRONT) | 1133 W COLUMBIA AVE | COMPLAINT | FAILED | View |