The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | MISSING OWNER POSTING. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
CHIMNEY | LOOSE BRICKS AT CHIMNEY. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY CAP MISSING. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | EAST WOOD PORCH HAS INCORRECT HANDRAILS, ROTTEN WORN STAIR TREADS AND DECKING, PORCH ROOF UNDERSIDE HAS WATER AND MOLD DAMAGED WOOD. WEST TWO STORY WOOD PORCH HAS UNDERSIZED AND OVERSPANNED 2X6 FLOOR JOISTS, UNKNOWN FOOTINGS, MISSING HANGERS, 1ST FLOOR/2ND FLOOR STAIR PITCH INCORRECT, STAIR TREADS ARE 2X8, TREADS ARE CRACKED AND BROKEN, INCORRECT SPLICES, 2X6 JOIST NOT BOLTED TO BUILDING, 2X6 FLOOR JOIST SITTING ON 2X4 LAYED FLAT, NOTCHED OUT JOIST, 3X6 SUPPORT COLUMNS NOT SITTING ON SOUND FOUNDATION, ROTTED DECKING, ALL WOOD WEATHERED AND DETERIORATED. ENTIRE PORCH SYSTEM IN DANGEROUS AND HAZARDOUS CONDITION. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST STAIRS GRADE TO BASEMENT MISSING GUARD/HANDRAILS. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTHWEST ENCLOSED PORCH HAS A NOTCHED OUT 2X10 HEADER, 6X6 SUPPORT COLUMN ON BROKEN FOUNDATION, 2X10 HEADER NAILED WITH 3 NAILS, ROTTED WOOD DECKING. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REPLACEMENT OF WEST WOOD PORCH/ENCLOSED WOOD PORCH WILL REQUIRE PROPER PLANS AND PERMITS. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURE AND JUNCTION BOX AT FRONT DECK CEILING. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE POWER SERVICE WITH IMPROPER CONNECTIONS AND RUSTED METER SOCKET. INSTALL PUBLIC METER AND PANEL. ALL METERS MUST BE IN SINGLE ENCLOSURE. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO BASEMENT REAR ENTRY DOOR. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. | 6622 S LOWE AVE | COMPLAINT | FAILED | View | |
PRV BALLCOCK,VB,OR AIR GAP | SILCOCK NORTHWEST ELEVATION. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF PROPERTY. | 6622 S LOWE AVE | COMPLAINT | FAILED | View |