Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 1:22 AM
PIN: 19104040140000
Property Address: 5235 S KOSTNER AVE
City - Zip: CHICAGO - 60632
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72030
2023 Tax District: 72014
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 6 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR STAIR STAIR SYSTEM ON NORTH ELEVATION OF BUILDING TO ATTIC WITH FOLLOWING DEFECTS,DIFFERENT AND RISER HEIGHTS THRU-OUT,CUPPED THREADS,BOWED 4X4 SUPPORT COLUMNS SCABED 2X4'S OVER 4X4 COLUMNS FOR SUPPORT,NO BEAM TO COLUMN BOLTS AT LANDING,NO JOISTS HANGER ON JOIST AT LANDING,GUARDRAILS AT 30" MUST BE AT 42",HANDRAIL AND GAURD RAIL DEFLECT UNDER LOAD,NO VISIBLE FOOTINGS FOR COLUMNS,PLANS AND PERMIT REQUIRED FOR REPAIRS 5235 S KOSTNER AVE COMPLAINT FAILED View
REPAIR STOOP CONCRETE SLAB STOOP SPALLING CONCRETE UNDER SIDE AND SURFACE.METAL GUARD RAIL AT 30" 5235 S KOSTNER AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR PROVIDE APPROVED PLANS AND PERMITS FOR SECOND FLOOR ADDITION (ATTIC) 5235 S KOSTNER AVE COMPLAINT FAILED View
EGRESS -BASEMENT ONLY ONE MEANS OF EGRESS FROM ATTIC 5235 S KOSTNER AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR STAIR SYSTEM ON NORTH ELEVATION OF BUILDING TO ATTIC WITH FOLLOWING DEFECTS,DIFFERENT AND RISER HEIGHTS THRU-OUT,CUPPED THREADS,BOWED 4X4 SUPPORT COLUMNS SCABED 2X4'S OVER 4X4 COLUMNS FOR SUPPORT,NO BEAM TO COLUMN BOLTS AT LANDING,NO JOISTS HANGER ON JOIST AT LANDING,GUARDRAILS AT 30" MUST BE AT 42",HANDRAIL AND GAURD RAIL DEFLECT UNDER LOAD,NO VISIBLE FOOTINGS FOR COLUMNS,PLANS AND PERMIT REQUIRED FOR REPAIRS 5235 S KOSTNER AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR PROVIDE APPROVED PLANS AND PERMITS FOR SECOND FLOOR ADDITION (ATTIC)LANSL 5235 S KOSTNER AVE COMPLAINT PASSED View