The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR DOOR FRAME | SOUTH BASEMENT DOOR FRAME - RAT HOLE. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | SOUTH BASEMENT STAIRWAYS - GRADE TO BASEMENT - GUARDRAILS - MISSING. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR PORCHES - ALL ELEVATIONS - BIRD FOULING - UNSANITARY CONDITIONS. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | SOUTH PORCH ROOF - WEAK AND SAGGING . PERMIT FOR PORCH ROOF REPAIRS. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
NO GASOLINE(LPG) STORAGE | SOUTHWEST PORCH - STORING PROPANE GAS. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | NORTH AND WEST LINTELS - RUSTED AND SAGGING. PERMIT REQUIRED FOR LINTEL REPLACEMENT. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH , SOUTH , AND WEST PARAPET WALLS - BULGING , SHIFTING , LOOSE , AND FALLING BRICKS WITH WASHED OUT MORTAR. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR COPING | SOUTH COPING TILES - LOOSE AND MISSING SECTIONS WITH WASHED OUT MORTAR. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH WALL AND PARAPET WALL - ABOVE 2ND FLOOR WINDOWS - LOOSE , SHIFTING , FALLING , AND BULGING BRICKS - WITH WASHED OUT MORTAR. OVER SIDEWALK DANGEROUS AND HAZARDOUS. PERMIT REQUIRED FOR ALL MASONRY REPAIRS. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | NORTH AND WEST ENTRY DOORS - GLASS PANES -BROKEN. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
PROTECT SIDEWALK DURING CONST | NORTH WALL AND PARAPET WALL ABOVE 2ND FLOOR WINDOWS -LOOSE , BULGING , SHIFTING , MISSING AND FALLING WITH WASHED OUT MORTAR . SIDEWALK CANOPY REQUIRED | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH PORCHES - ACCUMULATION OF FURNITURE , APPLIANCES , BOXES , PERSONAL ITEMS , JUNK AND DEBRIS - HAMPERING EGRESS. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | SOUTH AT PORCH AREAS - BASEMENT AND ON PORCH DECKS - ACCUMULATION OF APPLIANCES , FURNITURE , BOXES , BINS , JUNK , AND DEBRIS. 3215 W. - FRONT ENTRYWAY - ICE BUILD UP - FALLING HAZARD. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | SOUTHWEST PORCH AT 1ST - OPEN ELECTRICAL JUNCTION BOX . | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THROUGH 2015. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH - 2 , 3 STORY OPEN WOOD PORCHES - COLUMNS ERECTED ON CONCRETE SLABS AND CONCRETE BASES - FOUNDATION STATUS UNKNOWN. STACKED COLUMNS ONLY NAILED TOGETHER. COLUMN SPLICES ONLY NAILED. BEAMS ONLY NAILED TO COLUMNS - SOME WITH THIN GAGE METAL BRACKETS. 4 X 4 BEAMS SPAN 5' 1'' - WEAK AND SAGGING. 2 X 8 DECK JOISTS SPAN UP TO 17' LONG - SOME JOISTS SCABBED TOGETHER. DECK JOISTS ONLY NAILED TO HEADER AND RIM JOISTS. STRINGERS ONLY NAILED TO COLUMNS , HEADER JOISTS , DECK JOISTS AND EACH OTHER. TREADS - SPLIT AND WORN. LOOSE GUARDRAILS ONLY 35'' HIGH WITH LOOSE , BROKEN , AND MISSING PICKETS. DECKING WEAK WITH LOOSE SECTIONS. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRWAYS - GRADE TO 1ST - HANDRAILS - MISSING. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 3215 W. - FRONT INTERIOR STAIRWAY AT TOP CEILING - WATER LEAKING FROM CEILING. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | ALL FRONT INTERIOR STAIRWAYS - FURNACES INSTALLED AT CEILING AT TOP - CARBON MONOXIDE DETECTORS - MISSING. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 3219 W. - FRONT INTERIOR STAIRWAY AT CEILING - OPEN HOLE , WATER DAMAGED. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | WEST ENTRY DOOR - DOOR LOCKS - MISSING. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | FRONT INTERIOR STAIRWAYS THROUGHOUT - SMOKE DETECTORS CHIRPPING AND OUT OF SERVICE [ LOW BATTERY ]. | 5301 S SAWYER AVE | COMPLAINT | FAILED | View |