Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 4:48 AM
PIN: 20103120290000
Property Address: 5348 S CALUMET AVE
City - Zip: CHICAGO - 60615
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70010
2023 Tax District: 70120
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 11 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# NO OWNERSHIP INFORMATION SIGN. 5348 S CALUMET AVE COMPLAINT PASSED View
NO POSTED ADDRESS NO ADDRESS POST. 5348 S CALUMET AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM GRADE TO 3RD FLOOR REAR WOODEN PORCH SYSTEM: COLUMNS SITTING ON CONCRETE BLOCK FOUNDATION WITHOUT BASE ANCHORS. STRINGERS NOT BOLTED TO COLUMNS. LOOKOUT BEAMS PULLING AWAY FROM COLUMNS AND MISSING ANGLE FLANGES AT ALL LEVELS. GUARDRAILS BELOW 42" HIGH. RAILINGS AND RAILING POST LOOSEN AND DEFLECTING UNDER LOADS WITH NAILS STICKING OUT. RAILINGS WITH LOOSE PICKETS. IMPROPER COLUMN TO COLUMN SPLICE CONNECTION - ONLY TO TWO BOLTS OR WITHOUT BOLTS. NO JOIST HANGERS. REPAIR PERMIT NEEDED. NO PLANS REQUIRED AT THIS TIME. 5348 S CALUMET AVE COMPLAINT PASSED View
REPAIR INTERIOR WALLS/CEILING COLLAPSED CEILING WALLS AND PLASTER. HOLES ON WALLS. 5348 S CALUMET AVE COMPLAINT PASSED View
REPAIR INTERIOR WALLS/CEILING CEILING / WALL WATER DAMAGES. 5348 S CALUMET AVE COMPLAINT PASSED View
REPAIR/REPLACE SMOKE DETECTORS NON WORKING SMOKE DETECTOR. 5348 S CALUMET AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTOR. 5348 S CALUMET AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID NO CO DETECTOR. 5348 S CALUMET AVE COMPLAINT PASSED View
STRUCTURAL MEMBER, PIER BLOCK BROKEN AND ROTTED FIVE FLOOR JOISTS. 5348 S CALUMET AVE COMPLAINT PASSED View
SUBMIT STRUCT. ENG. RPT (INT.) SUPPORT COLUMNS MISSING FOUNDATION FOOTING AND NOT ANCHORD PROPERLY TO OTHER STRUCTURAL MEMBERS. 5348 S CALUMET AVE COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR REPAIR PERMIT REQUIRED TO REPLACE ALL ROTTED FLOOR JOISTS AND MISSING FOUNDATION FOOTINGS IN BASEMENT. 5348 S CALUMET AVE COMPLAINT PASSED View