The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | NO OWNERSHIP INFORMATION SIGN. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |
NO POSTED ADDRESS | NO ADDRESS POST. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | GRADE TO 3RD FLOOR REAR WOODEN PORCH SYSTEM: COLUMNS SITTING ON CONCRETE BLOCK FOUNDATION WITHOUT BASE ANCHORS. STRINGERS NOT BOLTED TO COLUMNS. LOOKOUT BEAMS PULLING AWAY FROM COLUMNS AND MISSING ANGLE FLANGES AT ALL LEVELS. GUARDRAILS BELOW 42" HIGH. RAILINGS AND RAILING POST LOOSEN AND DEFLECTING UNDER LOADS WITH NAILS STICKING OUT. RAILINGS WITH LOOSE PICKETS. IMPROPER COLUMN TO COLUMN SPLICE CONNECTION - ONLY TO TWO BOLTS OR WITHOUT BOLTS. NO JOIST HANGERS. REPAIR PERMIT NEEDED. NO PLANS REQUIRED AT THIS TIME. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | COLLAPSED CEILING WALLS AND PLASTER. HOLES ON WALLS. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | CEILING / WALL WATER DAMAGES. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | NON WORKING SMOKE DETECTOR. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | NO CO DETECTOR. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |
STRUCTURAL MEMBER, PIER BLOCK | BROKEN AND ROTTED FIVE FLOOR JOISTS. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | SUPPORT COLUMNS MISSING FOUNDATION FOOTING AND NOT ANCHORD PROPERLY TO OTHER STRUCTURAL MEMBERS. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | REPAIR PERMIT REQUIRED TO REPLACE ALL ROTTED FLOOR JOISTS AND MISSING FOUNDATION FOOTINGS IN BASEMENT. | 5348 S CALUMET AVE | COMPLAINT | PASSED | View |