Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 6:27 AM
PIN: 13243140460000
Property Address: 2832 W HENDERSON ST
City - Zip: CHICAGO - 60618
2023 Property Class: 202
2023 Township: 71 - Jefferson
2023 Neighborhood: 71082
2023 Tax District: 71163
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 15 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING- ENTRY REFUSED BY OWNERS BROTHER, UNVERIFIED DETECTORS, AND OCCUPANCY. UNABLE TO INSPECT INTERIRO STAIRWAYS, AND REAR EXTERIOR PORCH. 2ND FLOOR, AND BASEMENT -NO ENTRY, UNABLE TO VERIFY ITEM#2 FROM DISMISSED AH CASE#177902 OF:ILLEGAL CONVERSION. 2832 W HENDERSON ST COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR SIDE, AND REAR YARDS/ 6' HIGH WOODEN FENCE HAS BEEN ERECTED- NO PERMIT OBTAINED. 2832 W HENDERSON ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH STRUCTURE WITH THE FOLLOWING DEFECTS,1)HAND RAILS UNDER SIZE 32INCH.2) GUARD RAILS UNDER SIZED 36 INCH.3) INTERMEDIATE LANDING JOIST NAILED.4) RIM JOIST NAILED.5) STRINGER CONNECTIONS NAILED.6) NO VISEBLE FOOTINGS FOR 6X6 COLUMNS FOR INTERMIDEATE LANDINGS.7) PLANS AND PERMITS REQUIRED FOR REPAIRS. 2832 W HENDERSON ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS NO WORKING SMOKE DETECTORS PRESENT IN FRONT STAIRWAY, FIRST FLOOR APT, BASEMENT APT, LAUNDRY ROOM, BOILER ROOM. 2832 W HENDERSON ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID NO CARBON MONIXIDE DETECTOR PRESENT IN LAUNDRY ROOM ,BOILER ROOM. 2832 W HENDERSON ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND ATTIC OR RESTORE THE BUILDING TO ORIGINAL STATE. 2832 W HENDERSON ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH STRUCTURE WITH THE FOLLOWING DEFECTS,1)HAND RAILS UNDER SIZE 32INCH.2) GUARD RAILS UNDER SIZED 36 INCH.3) INTERMEDIATE LANDING JOIST NAILED.4) RIM JOIST NAILED.5) STRINGER CONNECTIONS NAILED.6) NO VISEBLE FOOTINGS FOR 6X6 COLUMNS FOR INTERMIDEATE LANDINGS.7) PLANS AND PERMITS REQUIRED FOR REPAIRS. 2832 W HENDERSON ST COMPLAINT PASSED View
INSTALL SMOKE DETECTORS NO WORKING SMOKE DETECTORS PRESENT IN FRONT STAIRWAY, FIRST FLOOR APT, BASEMENT APT, LAUNDRY ROOM, BOILER ROOM. 2832 W HENDERSON ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID NO CARBON MONIXIDE DETECTOR PRESENT IN LAUNDRY ROOM ,BOILER ROOM. 2832 W HENDERSON ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND ATTIC OR RESTORE THE BUILDING TO ORIGINAL STATE. 2832 W HENDERSON ST COMPLAINT PASSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES(INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN BASEMENT AND ATTIC WITHOUT PERMITS.OPEN FACE WALL SEPERATING FIRST FLOOR APT FROM STAIRWAY LEADING TO ATTIC, MAKE SHIFT DOORWAY AT ATTIC ENTRY, ONLY ONE EXIT FROM BASEMENT APT.SECONDARY EXIT FOR ATTIC IS THRU REAR BED ROOM. 2832 W HENDERSON ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND PERMIT FOR ALTERATIONS TO 2ND FLOOR & BASEMENT INCLUDING WALLS PLUMBING AND ELECTRIC FIXTURES. DWELLING UNITS ADDES TO 2ND FLOOR & BASEMENT. 2832 W HENDERSON ST COMPLAINT PASSED View
LIGHT AND VENT BASEMENT WINDOW DONT MEET LIGHT / VENT REQUIREMENTS 2832 W HENDERSON ST COMPLAINT PASSED View
EGRESS -BASEMENT BASEMENT UNIT ONLY ONE EXIT 2832 W HENDERSON ST COMPLAINT PASSED View
REPAIR/REBUILD GARAGE OR SHED GARAGE/ DOWNSPOUT- MISSING. 2832 W HENDERSON ST COMPLAINT FAILED View