Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 6:49 PM
PIN: 26081030450000
Property Address: 9805 S EWING AVE
City - Zip: CHICAGO - 60617
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70101
2023 Tax District: 70062
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 10 Violations
Violation Inspector Comments Address Category Status View
SUPPORT FIXTURES EAST AT GRADE [ PORCH ] - LOOSE AND HANGING LIGHT FIXTURE. 9805 S EWING AVE COMPLAINT CLOSED View
REPLACE D&H PORCH EAST 2 STORY OPEN WOOD PORCH - ROTTED 6 X 6 COLUMNS ERECTED ON CONCRETE BLOCKS - FOUNDATION STATUS UNKNOWN. COLUMNS OVERNOTCHED WITH 6 X 6 BEAMS AND 2 X 8 BEAMS WITHIN 6'' OF EACH OTHER - ONLY 1'' TO 3'' OF COLUMN WIDTH TO CARRY LOAD. UNDERSIZED 6 X 6 BEAMS OVERSPANNED AT 7' 5'' AND PULLING AWAY AT COLUMNS - 1/2'' TO 1'' GAPS AT COLUMN TO BEAM CONNECTIONS -ONLY NAILED [ SOME SECTIONS OF 6 X 6 BEAMS HAVE 2 X 8 BOARDS NAILED ALONG SIDE FOR ADDED SUPPORT ]. COLUMNS ARE ROTTED , TWISTED , SPLIT , STACKED , AND BUCKLING. PORCH IS VERY UNSTABLE WITH SOUTHEAST COLUMN NOT CONNECTED TO ROOF BEAM - VERY DANGEROUS AND HAZARDOUS. NORTHEAST COLUMN SPLICE AT 2ND IS VERY LOOSE AND UNSTABLE - BROKEN PIECES OF COLUMN AT SPLICE. NORTH AND SOUTH SECTIONS OF PORCH AT 2ND RACK AND MOVE 2'' TO 4'' AWAY FROM BUILDING - NO BRACING PROVIDED. NORTH 2ND LEVEL LEDGER BEAM IS NOT ATTACHED TO BUILDING [ FREE FLOATING ]. 2ND COLUMN FROM NORTH AT GRADE IS HALF SPLICED AND ONLY NAILED - BUCKLING. DECK JOIST ARE ONLY NAILED TO HEADER JOISTS AND 6 X 6 BEAMS. UNDERSIZED 2 X 8 JOISTS OVERSPANNED AT 11' AND SPACED 24'' ON CENTERS. BEAM POCKETS AT MASONARY WALL ARE OPEN AND MISSING MORTAR. ROOF BEAMS ARE ROTTED WITH OPEN FIRE CUTS AND ONLY NAILED TO COLUMNS EXCEPT SOUTH EAST BEAM - NOT ATTACHED [ FLOATING AND LOOSE ]. STRINGERS ONLY SCREWED OR NAILED TO COLUMNS AND JOISTS. OPEN STAIR RISERS WITH 5 1/2 '' TO 6'' GAP BETWEEN TREADS. LOOSE HAND AND GUARDRAILS WITH MANY SECTIONS ONLY NAILED TO COLUMNS WITH 1 NAIL. GUARDRAILS ONLY 39'' HIGH WITH LOOSE, BROKEN , AND MISSING PICKETS. PLANS AND PERMIT REQUIRED FOR PORCH REPLACEMENT. 9805 S EWING AVE COMPLAINT CLOSED View
SUBMIT FOR APPROVAL PLANS 9805 S EWING AVE COMPLAINT CLOSED View
MAINTAN BLDG IN SAFE CONDITION 9805 S EWING AVE COMPLAINT CLOSED View
REPAIR/WRECK DANGER RESID PREM 9805 S EWING AVE COMPLAINT CLOSED View
WATCHMAN 9805 S EWING AVE COMPLAINT CLOSED View
VACANT BUILDING - REGISTER 9805 S EWING AVE COMPLAINT CLOSED View
POST OWNER INFO ON ABDN BLDG 9805 S EWING AVE COMPLAINT CLOSED View
POST OWNER NAME OF VACNT BLDG VIOLATION CLOSED PER PCR 1180 9805 S EWING AVE COMPLAINT CLOSED View
REPAIR FENCE EAST 5' HIGH WOOD FENCE - LOOSE AND FALLING WITH BROKEN AND MISSING PICKETS. 9805 S EWING AVE COMPLAINT CLOSED View