Chicago Building Violations Data: 38 Violations
Violation Inspector Comments Address Category Status View
MAINTAIN WINDOW ROTTED WINDOW FRAMES ALL ELEVATIONS (14X-3-303.13) 6200 S INDIANA AVE COMPLAINT FAILED View
ADD BRANCH CIRCUITS APPEARS TO BE INSUFFICIENT BRANCH CIRCUITS AT APARTMENT PANELS ADD CIRCUITS AS REQUIRED 6200 S INDIANA AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION ALLOW ENTRY TO ENTIRE PROPERTY NO ENTRY TO 1 SOUTH AT TIME OF INSPECTION (14A-1-104.7) 6200 S INDIANA AVE COMPLAINT FAILED View
OBTAIN PERMIT FOR PLUMBING OBTAIN PERMIT BEFORE CONSTRUCTING, ALTERING OR USING PLUMBING SYSTEM 6200 S INDIANA AVE COMPLAINT FAILED View
FIRE & WATER DAMAGE ELECTRICAL SYSTEM APPEARS DAMAGED FROM SEVERE WATER INFILTRATION VISIBLE THROUGHOUT BUILDING REPAIR WHERE REQUIRED DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
PROV 1"AIR GAP ABV OVRFLW RIM SUBMERGED WATER SUPPLY OUTLETS TO ALL BATHROOM TUBS THROUGHOUT PREMISES DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
DEFECTIVE SERVICE OVERHEAD SERVICE CABLES TANGLED WITH OVER LOW VOLTAGE CABLES ABOVE REAR YARD OVERHEAD SERVICE CABLES VISIBLY DETERIORATED AT ATTACHMENT POINT ON BUILDING MAIN DISCONNECT SHOWING DETERIORATION AND DOOR NOT COMPLETELY CLOSED OVERHEAD SERVICE DOES NOT APPEAR SECURELY ATTACHED TO BUILDING ENSURE SERVICE IN APPROVED CONDITION DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
INSTALL ILLUMINATION MISSING ILLUMINATION EXTERIOR ENTRIES 6200 S INDIANA AVE COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET TUB FAUCET AT 25 BATHROOM LEAKING 6200 S INDIANA AVE COMPLAINT FAILED View
PROPER SIZE GRD ELECTRODE COND NO VISIBLE WATER GROUND ENSURE SERVICE GROUNDED IN APPROVED MANNER DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY BARS ON REAR DOORS FOR UNITS 1 NORTH AND 2ND OBSTRUCTING EGRESS (D&H) (14X-5-505.1.2) 6200 S INDIANA AVE COMPLAINT FAILED View
REMOVE STAGNANT WATER BSMT STAGNANT WATER PRESENT AT BASEMENT FLOOR DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL WASHED OUT MORTAR AT SOUTH,NORTH,AND EAST ELEVATIONS (14X-3-303.1.1) 6200 S INDIANA AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS CORD AND PLUG CONNECTED READING LAMP INSTALLED NEAR TUB AT 1ST FLOOR SOUTH APARTMENT BATHROOM NOT APPROVED FOR USE DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
INSTALL VENT PIPE FOR TRAP UNAPPROVED-5-TRAPS TO ALL BATHROOM LAVATORIES THROUGHOUT PREMISES 6200 S INDIANA AVE COMPLAINT FAILED View
SYSTEM III NO BATTERY LIGHTS BUILDING CONTAINS 5 APARTMENTS DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS DEFECTIVE, CORRODED DEVICES VISIBLE AT BASEMENT AND SOUTH APARTMENTS REPLACE WHERE REQUIRED 6200 S INDIANA AVE COMPLAINT FAILED View
REMV RARELY USED FIXTURE ABANDONED PLUMBING FIXTURES AT 2N (KITCHEN SINK, BATHROOM LAVATORY, TUB) AND BASEMENT LAUNDRY TUBS, DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
REPAIR SKYLIGHT SKYLIGHT LEAKING AT COMMON AREA HALLWAY (D&H) 6200 S INDIANA AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES MISSING GLOBES, BROKEN INOPERABLE LIGHT FIXTURES VISIBLE AT BASEMENT, SOUTH APARTMENTS, FRONT STAIRS, FRONT ENTRY REPAIR/REPLACE WHERE REQUIRED 6200 S INDIANA AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER ALL CEILINGS THROUGHOUT 1 NORTH, 2 NORTH AND 2 SOUTH WATER DAMAGED AND LEAKING WITH MISSING SECTIONS THROUGHOUT (D&H) (14X-12-1202.5.2) 6200 S INDIANA AVE COMPLAINT FAILED View
REPLACE D&H PORCH REAR PROPERTY 2 STORY OPEN WOOD PORCH (DANGEROUS AND HAZARDOUS) PORCH COLLAPSED ROTTED CONNECTION POINTS AT STRUCTURAL BEAM AND POSTS CONNECTIONS WHERE REMAINING PORCH EXISTS SOUTH SECTION OF PORCH CURRENTLY COLLAPSED, NORTH SECTIONS SHOWING SIGNS OF COLLAPSING (14X3-303.1.1) 6200 S INDIANA AVE COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU BASEMENT CEILINGS MISSING SECTIONS OF FIRE SEPARATION MULTIPLE SECTIONS THROUGHOUT 1HR FIRE SEPARATION REQUIRED THROUGHOUT BASEMENT CEILINGS (14X-5-502.3) 6200 S INDIANA AVE COMPLAINT FAILED View
WORKING SPACE DEBRIS, CLUTTER, STORAGE IN FRONT OF ELECTRICAL PANELS AND MAIN DISCONNECT AT BASEMENT DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
UNSANITARY CONDITIONS-ANIMALS UNIT 2 NORTH DOG FECES THROUGHOUT LIVING ROOM AT TIME OF INSPECTION (7-12-420) 6200 S INDIANA AVE COMPLAINT FAILED View
UNAPPROVED CORDS EXCESSIVE EXTENSION CORDS SOUTH APARTMENTS REMOVE WHERE REQUIRED DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE MISSING LAVATORY AT 25 BATHROOM WASTE CONNECTION LEFT OPEN DANGEROUS AND HAZARDOUS OPEN SEWER 6200 S INDIANA AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING 6200 S INDIANA AVE COMPLAINT FAILED View
INSTALL GFCI'S INSTALL GFCI PROTECTION KITCHEN, BATH, BASEMENT, LAUNDRY, EXTERIOR 6200 S INDIANA AVE COMPLAINT FAILED View
DETERIORATED CONDUCTORS DETERIORATED CLOTH WIRING VISIBLE AT OPEN BOX FRONT FOYER CEILING REMOVE THROUGHOUT WHERE REQUIRED DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG NO HOT WATER TO ENTIRE PREMISES WATER HEATER AT BASEMENT IS OUT OF ORDER UNSANITARY CONDITION 6200 S INDIANA AVE COMPLAINT FAILED View
ADD RECEPTACLES ADD RECEPTACLE OUTLETS AT SOUTH APARTMENTS AND WHERE REQUIRED TO PREVENT EXTENSION CORD USAGE DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
INDIRECT CONN.FOR WATER SUPPLY BOILER AT BASEMENT IS DIRECTLY CONNECTED TO WATER SUPPLY WITHOUT ANY MEANS OF BACKFLOW CROSS CONTAMINATION PROTECTION 6200 S INDIANA AVE COMPLAINT FAILED View
EXPOSED WIRING FIXTURES LIGHT FIXTURES HANGING BY WIRES FRONT ENTRY DAMAGED PENDANT FIXTURE WIRING VARIOUS AREAS REPLACE/REPAIR DANGEROUS AND HAZARDOUS 6200 S INDIANA AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE UNAPPROVED FLEXIBLE WATER SUPPLY PIPING TO BASEMENT WATER HEATER AND BATHROOM LAVATORIES THROUGHOUT PREMISES 6200 S INDIANA AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE FRONT ENTRY DOOR MISSING LOCK AND KNOB 6200 S INDIANA AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE SPACE HEATERS USED AS MEANS OF HEAT THROUGHOUT PROPERTY,STOVE ALSO USED AS HEAT SOURCE AT UNIT 1 NORTH (D&H) (14X-8-802.2) 6200 S INDIANA AVE COMPLAINT FAILED View
OBTAIN PERMIT TO CORRECT VIOLATIONS (14A-4-404.6) 6200 S INDIANA AVE COMPLAINT FAILED View