Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MAINTAIN WINDOW | ROTTED WINDOW FRAMES ALL ELEVATIONS (14X-3-303.13) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
ADD BRANCH CIRCUITS | APPEARS TO BE INSUFFICIENT BRANCH CIRCUITS AT APARTMENT PANELS ADD CIRCUITS AS REQUIRED | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ALLOW ENTRY TO ENTIRE PROPERTY NO ENTRY TO 1 SOUTH AT TIME OF INSPECTION (14A-1-104.7) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | OBTAIN PERMIT BEFORE CONSTRUCTING, ALTERING OR USING PLUMBING SYSTEM | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
FIRE & WATER DAMAGE | ELECTRICAL SYSTEM APPEARS DAMAGED FROM SEVERE WATER INFILTRATION VISIBLE THROUGHOUT BUILDING REPAIR WHERE REQUIRED DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
PROV 1"AIR GAP ABV OVRFLW RIM | SUBMERGED WATER SUPPLY OUTLETS TO ALL BATHROOM TUBS THROUGHOUT PREMISES DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | OVERHEAD SERVICE CABLES TANGLED WITH OVER LOW VOLTAGE CABLES ABOVE REAR YARD OVERHEAD SERVICE CABLES VISIBLY DETERIORATED AT ATTACHMENT POINT ON BUILDING MAIN DISCONNECT SHOWING DETERIORATION AND DOOR NOT COMPLETELY CLOSED OVERHEAD SERVICE DOES NOT APPEAR SECURELY ATTACHED TO BUILDING ENSURE SERVICE IN APPROVED CONDITION DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | MISSING ILLUMINATION EXTERIOR ENTRIES | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | TUB FAUCET AT 25 BATHROOM LEAKING | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
PROPER SIZE GRD ELECTRODE COND | NO VISIBLE WATER GROUND ENSURE SERVICE GROUNDED IN APPROVED MANNER DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | BARS ON REAR DOORS FOR UNITS 1 NORTH AND 2ND OBSTRUCTING EGRESS (D&H) (14X-5-505.1.2) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | STAGNANT WATER PRESENT AT BASEMENT FLOOR DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WASHED OUT MORTAR AT SOUTH,NORTH,AND EAST ELEVATIONS (14X-3-303.1.1) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | CORD AND PLUG CONNECTED READING LAMP INSTALLED NEAR TUB AT 1ST FLOOR SOUTH APARTMENT BATHROOM NOT APPROVED FOR USE DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
INSTALL VENT PIPE FOR TRAP | UNAPPROVED-5-TRAPS TO ALL BATHROOM LAVATORIES THROUGHOUT PREMISES | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
SYSTEM III | NO BATTERY LIGHTS BUILDING CONTAINS 5 APARTMENTS DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | DEFECTIVE, CORRODED DEVICES VISIBLE AT BASEMENT AND SOUTH APARTMENTS REPLACE WHERE REQUIRED | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
REMV RARELY USED FIXTURE | ABANDONED PLUMBING FIXTURES AT 2N (KITCHEN SINK, BATHROOM LAVATORY, TUB) AND BASEMENT LAUNDRY TUBS, DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
REPAIR SKYLIGHT | SKYLIGHT LEAKING AT COMMON AREA HALLWAY (D&H) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | MISSING GLOBES, BROKEN INOPERABLE LIGHT FIXTURES VISIBLE AT BASEMENT, SOUTH APARTMENTS, FRONT STAIRS, FRONT ENTRY REPAIR/REPLACE WHERE REQUIRED | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | ALL CEILINGS THROUGHOUT 1 NORTH, 2 NORTH AND 2 SOUTH WATER DAMAGED AND LEAKING WITH MISSING SECTIONS THROUGHOUT (D&H) (14X-12-1202.5.2) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PROPERTY 2 STORY OPEN WOOD PORCH (DANGEROUS AND HAZARDOUS) PORCH COLLAPSED ROTTED CONNECTION POINTS AT STRUCTURAL BEAM AND POSTS CONNECTIONS WHERE REMAINING PORCH EXISTS SOUTH SECTION OF PORCH CURRENTLY COLLAPSED, NORTH SECTIONS SHOWING SIGNS OF COLLAPSING (14X3-303.1.1) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT CEILINGS MISSING SECTIONS OF FIRE SEPARATION MULTIPLE SECTIONS THROUGHOUT 1HR FIRE SEPARATION REQUIRED THROUGHOUT BASEMENT CEILINGS (14X-5-502.3) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
WORKING SPACE | DEBRIS, CLUTTER, STORAGE IN FRONT OF ELECTRICAL PANELS AND MAIN DISCONNECT AT BASEMENT DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | UNIT 2 NORTH DOG FECES THROUGHOUT LIVING ROOM AT TIME OF INSPECTION (7-12-420) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | EXCESSIVE EXTENSION CORDS SOUTH APARTMENTS REMOVE WHERE REQUIRED DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | MISSING LAVATORY AT 25 BATHROOM WASTE CONNECTION LEFT OPEN DANGEROUS AND HAZARDOUS OPEN SEWER | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
INSTALL GFCI'S | INSTALL GFCI PROTECTION KITCHEN, BATH, BASEMENT, LAUNDRY, EXTERIOR | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
DETERIORATED CONDUCTORS | DETERIORATED CLOTH WIRING VISIBLE AT OPEN BOX FRONT FOYER CEILING REMOVE THROUGHOUT WHERE REQUIRED DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER TO ENTIRE PREMISES WATER HEATER AT BASEMENT IS OUT OF ORDER UNSANITARY CONDITION | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLE OUTLETS AT SOUTH APARTMENTS AND WHERE REQUIRED TO PREVENT EXTENSION CORD USAGE DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
INDIRECT CONN.FOR WATER SUPPLY | BOILER AT BASEMENT IS DIRECTLY CONNECTED TO WATER SUPPLY WITHOUT ANY MEANS OF BACKFLOW CROSS CONTAMINATION PROTECTION | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | LIGHT FIXTURES HANGING BY WIRES FRONT ENTRY DAMAGED PENDANT FIXTURE WIRING VARIOUS AREAS REPLACE/REPAIR DANGEROUS AND HAZARDOUS | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | UNAPPROVED FLEXIBLE WATER SUPPLY PIPING TO BASEMENT WATER HEATER AND BATHROOM LAVATORIES THROUGHOUT PREMISES | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT ENTRY DOOR MISSING LOCK AND KNOB | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | SPACE HEATERS USED AS MEANS OF HEAT THROUGHOUT PROPERTY,STOVE ALSO USED AS HEAT SOURCE AT UNIT 1 NORTH (D&H) (14X-8-802.2) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT TO CORRECT VIOLATIONS (14A-4-404.6) | 6200 S INDIANA AVE | COMPLAINT | FAILED | View |