Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR 1-STORY WOOD PORCH/ UNDERSIZED 2X6 DECK JOISTS SPAN 8 FEET. RIM JOISTS AND HEADER JOISTS ARE ONLY NAILED TO COLUMNS. STRINGERS - UPPER ENDS ARE INADEQUATELY SUPPORTED WITH NAILS ONLY. ALL RAILINGS ARE ONLY NAILED TO COLUMNS AND POSTS. STAIR RAILINGS ARE MISSING PICKETS.PERMIT ONLY REQUIRED TO REPAIR REAR PORCH. | 5011 S LAPORTE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR GRADE TO BASEMENT EXTERIOR STAIRWAY - MISSING HAND RAIL. | 5011 S LAPORTE AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | FRONT ELEVATION/ ATTIC WINDOW SILL - WASHED OUT MORTAR. | 5011 S LAPORTE AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | FRONT ELEVATION/ GABLE EAVES - MISSING SECTIONS OF METAL CAPPING. | 5011 S LAPORTE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ENTRY REFUSED BY OWNER. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 5011 S LAPORTE AVE | COMPLAINT | FAILED | View |