Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | EXTERIOR WALLS-LOOSE, TORN METAL SIDING; SHARP EDGES. | 5221 S WOOD ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH-4X4 COLUMNS ARE SET ON CONCRETE PADS; SOUTH COLUMN IS SET IN A FRACTURED CONCRETE BASE; FOUNDATIONS STATUS IS UNKNOWN. FRACTURED STRINGERS. FRACTURED CONCRETE STOOP. WORN, LOOSE TREADS / RISERS. MOST MEMBERS ARE ONLY TOE NAILED TOGETHER AT THE CONNECTIONS. PLANS AND PERMIT REQUIRED FOR PORCH REPLACEMENT. | 5221 S WOOD ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED DETECTORS AND COMPLAINT OF: SR#101547059-BASEMENT WAS FLOODED; BAD ODOR; MOLD; RODENTS. | 5221 S WOOD ST | COMPLAINT | FAILED | View |
REPAIR FENCE | FRONT STAIR RAIL WEAK AND RUSTED, DE CKING ROTTED, STRINGERS OVERCUT, TREADS UNDERSIZED, ONE 2X8 JOIST AND 2X4 POST SUPPORTING DECKING AND LEDGER. FRONT PORCH REQUIRE A PERMIT FOR REPAIR. | 5221 S WOOD ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT GATE DOUBLE KEY LOCK. | 5221 S WOOD ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR GATE CHAIN AND PADLOCK. | 5221 S WOOD ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED | FENCE OVER 5FT HIGH REQUIRE A PERMIT. | 5221 S WOOD ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO ENTRY, UNABLE TO VERIFY COMPLAINT AT 1ST AND 2ND HOLES IN BATHROOM FLOOR AND RATS. | 5221 S WOOD ST | COMPLAINT | FAILED | View |