The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
STOP ALL WORK. SEC. 13-12-050; 13-12-080; 13-32-035. | 2601 W DEVON AVE | COMPLAINT | FAILED | View | |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMITS FOR INTERIOR ALTERATION OF THE 2ND FLOOR REMOVING PARTITION WALL. NO PLAN OR PERMIT. | 2601 W DEVON AVE | COMPLAINT | FAILED | View |
SEND EX. METAL LETTER | 2601 W DEVON AVE | COMPLAINT | FAILED | View | |
SEND EX. METAL LETTER | 2601 W DEVON AVE | COMPLAINT | FAILED | View | |
PROTECT METAL MEMBERS | 2601 W DEVON AVE | COMPLAINT | FAILED | View | |
MAINTAIN MECH. VENT SYSTEM | (1) BLACK IRON DUCT AND EXHAUST FAN ARE IN VERY BAD CONDITION AND MUST NOT BE USED UNTIL REMOVED AND REPLACED WITH NEW DUCTWORK, FAN, FASTENERS ETC (2) ROOF TOP UNIT SERVING JEWELRY STORE MUST BE PROVIDED WITH SUPPLY & EXHAUST VENTILATION 18-28-102.3I | 2601 W DEVON AVE | COMPLAINT | FAILED | View |
SUBMIT PLANS/GET VENT PERMIT | PERMIT IS REQUIRED IF INSTALLING NEW GREASE DUCT EXHAUST SYSTEM 13-32-020 | 2601 W DEVON AVE | COMPLAINT | FAILED | View |
OUTSIDE AIR 15FT | WHEN PROVIDING OUTSIDE AIR TO ROOF TOP UNITS MAKE SURE THERE IS A 15FT SEPARATION FROM ANY EXHAUST 18-28-401-5.2 | 2601 W DEVON AVE | COMPLAINT | FAILED | View |
PROVIDE MINIMUM VENT QUANTITY | PROVIDE VENTILATION TO JEWELRY STORE 18-28-403 | 2601 W DEVON AVE | COMPLAINT | FAILED | View |
PROVIDE SUPPLY | PROVIDE 1 CFM SUPPLY PER SQ FT OF FLOOR AREA OF JEWELRY STORE 18-28-403.3 | 2601 W DEVON AVE | COMPLAINT | FAILED | View |
GIVE VENT OPENINGS % FL. AREA | PROVIDE 1 CFM EXHAUST PER SQ FT OF FLOOR AREA OF JEWELRY STORE 18-28-403.3 | 2601 W DEVON AVE | COMPLAINT | FAILED | View |
GIVE VENT OPENINGS % FL. AREA | PROVIDE 1 CFM EXHAUST PER SQ FT OF FLOOR ARE TO JEWELRY STORE 18-28-403.3 | 2601 W DEVON AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | ARRANGE INSPECTION AFTER VIOLATIONS ARE CORRECTED 13-12-100 13-20-290 13-32-270 | 2601 W DEVON AVE | COMPLAINT | FAILED | View |
REMOVE | REMOVE UNUSABLE BLACK IRON DUCT WORK THAT IS BREAKING APART AND PULLING AWAY FROM WALL FASTENERS AND CAUSING A DANGEROUS AND HAZARDOUS SAFETY CONCERN 13-16-070 13-16-060 18-28-102.3 18-28-506.3.4 | 2601 W DEVON AVE | COMPLAINT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | REMOVE BLACK IRON GREASE DUCT CAUSING PUBLIC SAFETY CONCERN AND ARRANGE INSPECTION TO VERIFY REMOVAL 13-12-100 13-20-290 13-28-102.3 13-32-270 | 2601 W DEVON AVE | COMPLAINT | PASSED | View |
ARRANGE FOR INSPECTION | CALL 312-746-8437 & ASK FOR INSPECTOR #655. | 2601 W DEVON AVE | PERIODIC | PASSED | View |
ACCESS TO ROOF | UNIT LOCATED ON THE ROOF. (SEC.13-12-100,13-192-070) | 2601 W DEVON AVE | PERIODIC | PASSED | View |
SEND EX. METAL LETTER | ENGINEER REPORT | 2601 W DEVON AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | SEE NOTICE # 11464 | 2601 W DEVON AVE | PERMIT | PASSED | View |