Last Modification Date: 2024-08-30 @ 2:27 PM
PIN: 19103240310000
Property Address: 5424 S KENNETH AVE
City - Zip: CHICAGO - 60632
2023 Property Class: 202
2023 Township: 72 - Lake
2023 Neighborhood: 72030
2023 Tax District: 72014
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 40 Violations
Violation Inspector Comments Address Category Status View
CHIMNEY CAPPING MISSING CHIMNEY CAP AT THE WEST ELEVATION. 5424 S KENNETH AVE COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT CEILING WITHIN ATTIC AREA WATER DAMAGED THROUGHOUT. 5424 S KENNETH AVE COMPLAINT FAILED View
EXPOSED WIRING D&H REMOVE EXPOSED WIRING THROUGH-OUT BUILDING 5424 S KENNETH AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMITS REQUIRED FOR ADDITION ADDED TO REAR OF PROPERTY (2). CANOPY ADDED TO FRONT OF PROPERTY (3). ATTIC CONVERSION TO NOW 1 BATHROOM AND ONE BEDROOM NO PLANS OR PERMITS ON FILE FOR CURRENT CONDITIONS AT PROPERTY. 5424 S KENNETH AVE COMPLAINT FAILED View
STRUCTURAL MEMBER, PIER BLOCK ROOF RIDGE AT PROPERTY APPEAR TO BE LEANING INWARD 5424 S KENNETH AVE COMPLAINT FAILED View
SUBMIT STRUCT. ENG. RPT (INT.) SUBMIT STRUCTURAL ENGINEERS REPORT FOR CURRENT ROOF CONDITIONS, CURRENTLY ROOF ALTERATIONS FOR ATTIC CONVERSION APPEAR TO BE DEFECTIVE AND CAUSING THE ROOF RIDGE TO SAG INWARD. 5424 S KENNETH AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS BOARDED WINDOW AT THE SOUTH ELEVATION 5424 S KENNETH AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTORS AT PROPERTY 5424 S KENNETH AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTOR THROUGHOUT PROPERTY. 5424 S KENNETH AVE COMPLAINT FAILED View
STRUCTURAL MEMBER, PIER BLOCK FLOOR DEFLECTING UNDER LIVE LOAD THROUGHOUT PROPERTY. 5424 S KENNETH AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM STAIR SYSTEM TO ATTIC AREA RAILING LOOSE AND SHAKY 5424 S KENNETH AVE COMPLAINT FAILED View
PROVIDE HOT WATER TANK HAS NO DRAIN SAFE PAN 18.29.605.2.1 5424 S KENNETH AVE COMPLAINT FAILED View
INSTALL GFCI'S D&H RECEPTACLE OUTLETS INSTALLED IN BATHROOMS, GARAGES, COUNTERTOP SPACES, UNFINISHED BASEMENTS AND OUTDOOR LOCATIONS SHALL HAVE GROUND FAULT PROTECTION FOR PERSONNEL 5424 S KENNETH AVE COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR 5424 S KENNETH AVE COMPLAINT FAILED View
PROTECT PIPES FROM FREEZING 1/2 COPPER WATERLINE RUNNING ALONG SIDE OF PROPERTY ON NORTH ELEVATION FOR SPIGOT IS NOT PROTECTED FROM ELEMENTS 5424 S KENNETH AVE COMPLAINT FAILED View
PRV FLOOR DRAIN WITH METAL STR NO FLOOR DRAIN AT HOT WATER TANK LOCATION 5424 S KENNETH AVE COMPLAINT FAILED View
CONTINUITY OF RACEWAYS D&H PROVIDE GROUNDING CONTINUITY FOR ELECTRICAL CABLE, CONDUIT, BOXES THROUGHOUT BUILDING 5424 S KENNETH AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FITTINGS 1/2 COPPER WATER LINE CINNECTION IS INSTALLED WITH PLASTIC HOSE AND CLAMPS FITTINGS AT NORTH ELEVATION 5424 S KENNETH AVE COMPLAINT FAILED View
D&H REMOVE ADDITIONAL PANEL LOCATED WITHIN ADDITON TO BUILDING (ADDITION IS ILLEGLE) 5424 S KENNETH AVE COMPLAINT FAILED View
CORRODED CONDUIT & EQUIP D&H REPLACE RUSTED AND DETERIORATED, OR CORRODED CONDUIT, BOXES, ARMORED CABLE, ETC 5424 S KENNETH AVE COMPLAINT FAILED View
STOP LEAKING WATER 1ST FLOOR LAVATORY WASTE PIPE HAS A LEAK 5424 S KENNETH AVE COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK 5424 S KENNETH AVE COMPLAINT FAILED View
ABANDONED EQUIPMENT D&H REMOVE ALL ABANDONED RACEWAYS, CABLE, CONDUCTORS, CONDUIT, BOXES AND ELECTRICAL EQUIPMENT 5424 S KENNETH AVE COMPLAINT FAILED View
PANEL SCHEDULES D&H PROVIDE DETAILED AND LEGIBLE PANEL SCHEDULE 5424 S KENNETH AVE COMPLAINT FAILED View
SEAL DRAIN OPENING UNUSD FIXTR POTABLE WATER CONNECTION AT KITCHEN SINK HAS NO AIR CHAMBERS IR AIR ARESTORS 5424 S KENNETH AVE COMPLAINT FAILED View
OBTAIN ELECTRICAL PERMIT AND LICENSED ELECTRICIAN TO PERFORM WORK 5424 S KENNETH AVE COMPLAINT FAILED View
RMV PLBFIX INSTALLD W/0 PERMIT 5424 S KENNETH AVE COMPLAINT FAILED View
ADD RECEPTACLES D&H ADD ADDITONAL RECEPTACLES TO EASE EXTENSION CORD USAGE 5424 S KENNETH AVE COMPLAINT FAILED View
PRV BALLCOCK,VB,OR AIR GAP NO VACUUM BREAKER AT HOSE BIBB ON EAST ELEVATION 5424 S KENNETH AVE COMPLAINT FAILED View
GROUNDING RECEPTACLES D&H INSTALL ALL GROUNDING RECEPTACLES THRUOUGH-OUT BUILDING 5424 S KENNETH AVE COMPLAINT FAILED View
INSTALL VENT PIPE FOR TRAP NO VENT FOR P-TRAP AT KITCHEN SINK AND LAUNDRY PLUMBING SYSTEM 5424 S KENNETH AVE COMPLAINT FAILED View
INSTALL VENT PIPE FOR TRAP LAUNDRY SINK P-TRAP HAS NO CONNECTION TO PLUMBING VENT SYSTEM 5424 S KENNETH AVE COMPLAINT FAILED View
OUTDOOR ARMORED CABLE D&H REMOVE ARMORED CABLE EXPOSED TO WEATHER AND MOISTURE 5424 S KENNETH AVE COMPLAINT FAILED View
PROVIDE HOT WATER TANK HAS NO DIELETRIC UNION CONNECTORS AT POTABLE WATER CONNECTIONS 5424 S KENNETH AVE COMPLAINT FAILED View
BOND AROUND FITTINGS D&H INSTALL BONDING CONDUCTOR ACROSS WATER METER (NOT VISIBLE) 5424 S KENNETH AVE COMPLAINT FAILED View
CORD WIRED EQUIPMENT D&H REMOVE UNAPPROVED CORD SUPPLIED TO PERMENATELY INSTALLED APPLIANCE 5424 S KENNETH AVE COMPLAINT FAILED View
ARMORED CABLE D&H REMOVE ARMORED CABLE THROUGH-OUT INTERIOR AND EXTERIOR OF BUILDING 5424 S KENNETH AVE COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET DEFECTIVE KITCHEN FAUCET AT KITCHEN SINK 5424 S KENNETH AVE COMPLAINT FAILED View
PRV DISCHARGE PIPE FROM PRV HOT WATER TANK T&P VALVE HAS NO EXTENDING PIPE CONNECTION TO SAFE PAN 5424 S KENNETH AVE COMPLAINT FAILED View
PROVIDE AIR CHAMERS LAUNDRY POTABLE WATER CONNECTIONS HAS NO AIR CHAMBERS OR ARESTORS 5424 S KENNETH AVE COMPLAINT FAILED View