The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CHIMNEY CAPPING | MISSING CHIMNEY CAP AT THE WEST ELEVATION. | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | CEILING WITHIN ATTIC AREA WATER DAMAGED THROUGHOUT. | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | D&H REMOVE EXPOSED WIRING THROUGH-OUT BUILDING | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS REQUIRED FOR ADDITION ADDED TO REAR OF PROPERTY (2). CANOPY ADDED TO FRONT OF PROPERTY (3). ATTIC CONVERSION TO NOW 1 BATHROOM AND ONE BEDROOM NO PLANS OR PERMITS ON FILE FOR CURRENT CONDITIONS AT PROPERTY. | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | ROOF RIDGE AT PROPERTY APPEAR TO BE LEANING INWARD | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | SUBMIT STRUCTURAL ENGINEERS REPORT FOR CURRENT ROOF CONDITIONS, CURRENTLY ROOF ALTERATIONS FOR ATTIC CONVERSION APPEAR TO BE DEFECTIVE AND CAUSING THE ROOF RIDGE TO SAG INWARD. | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BOARDED WINDOW AT THE SOUTH ELEVATION | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS AT PROPERTY | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR THROUGHOUT PROPERTY. | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | FLOOR DEFLECTING UNDER LIVE LOAD THROUGHOUT PROPERTY. | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | STAIR SYSTEM TO ATTIC AREA RAILING LOOSE AND SHAKY | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
PROVIDE | HOT WATER TANK HAS NO DRAIN SAFE PAN 18.29.605.2.1 | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
INSTALL GFCI'S | D&H RECEPTACLE OUTLETS INSTALLED IN BATHROOMS, GARAGES, COUNTERTOP SPACES, UNFINISHED BASEMENTS AND OUTDOOR LOCATIONS SHALL HAVE GROUND FAULT PROTECTION FOR PERSONNEL | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | 5424 S KENNETH AVE | COMPLAINT | FAILED | View | |
PROTECT PIPES FROM FREEZING | 1/2 COPPER WATERLINE RUNNING ALONG SIDE OF PROPERTY ON NORTH ELEVATION FOR SPIGOT IS NOT PROTECTED FROM ELEMENTS | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
PRV FLOOR DRAIN WITH METAL STR | NO FLOOR DRAIN AT HOT WATER TANK LOCATION | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | D&H PROVIDE GROUNDING CONTINUITY FOR ELECTRICAL CABLE, CONDUIT, BOXES THROUGHOUT BUILDING | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | 1/2 COPPER WATER LINE CINNECTION IS INSTALLED WITH PLASTIC HOSE AND CLAMPS FITTINGS AT NORTH ELEVATION | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
D&H REMOVE ADDITIONAL PANEL LOCATED WITHIN ADDITON TO BUILDING (ADDITION IS ILLEGLE) | 5424 S KENNETH AVE | COMPLAINT | FAILED | View | |
CORRODED CONDUIT & EQUIP | D&H REPLACE RUSTED AND DETERIORATED, OR CORRODED CONDUIT, BOXES, ARMORED CABLE, ETC | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 1ST FLOOR LAVATORY WASTE PIPE HAS A LEAK | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | 5424 S KENNETH AVE | COMPLAINT | FAILED | View | |
ABANDONED EQUIPMENT | D&H REMOVE ALL ABANDONED RACEWAYS, CABLE, CONDUCTORS, CONDUIT, BOXES AND ELECTRICAL EQUIPMENT | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
PANEL SCHEDULES | D&H PROVIDE DETAILED AND LEGIBLE PANEL SCHEDULE | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
SEAL DRAIN OPENING UNUSD FIXTR | POTABLE WATER CONNECTION AT KITCHEN SINK HAS NO AIR CHAMBERS IR AIR ARESTORS | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
OBTAIN ELECTRICAL PERMIT AND LICENSED ELECTRICIAN TO PERFORM WORK | 5424 S KENNETH AVE | COMPLAINT | FAILED | View | |
RMV PLBFIX INSTALLD W/0 PERMIT | 5424 S KENNETH AVE | COMPLAINT | FAILED | View | |
ADD RECEPTACLES | D&H ADD ADDITONAL RECEPTACLES TO EASE EXTENSION CORD USAGE | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
PRV BALLCOCK,VB,OR AIR GAP | NO VACUUM BREAKER AT HOSE BIBB ON EAST ELEVATION | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
GROUNDING RECEPTACLES | D&H INSTALL ALL GROUNDING RECEPTACLES THRUOUGH-OUT BUILDING | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
INSTALL VENT PIPE FOR TRAP | NO VENT FOR P-TRAP AT KITCHEN SINK AND LAUNDRY PLUMBING SYSTEM | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
INSTALL VENT PIPE FOR TRAP | LAUNDRY SINK P-TRAP HAS NO CONNECTION TO PLUMBING VENT SYSTEM | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
OUTDOOR ARMORED CABLE | D&H REMOVE ARMORED CABLE EXPOSED TO WEATHER AND MOISTURE | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
PROVIDE | HOT WATER TANK HAS NO DIELETRIC UNION CONNECTORS AT POTABLE WATER CONNECTIONS | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
BOND AROUND FITTINGS | D&H INSTALL BONDING CONDUCTOR ACROSS WATER METER (NOT VISIBLE) | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
CORD WIRED EQUIPMENT | D&H REMOVE UNAPPROVED CORD SUPPLIED TO PERMENATELY INSTALLED APPLIANCE | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
ARMORED CABLE | D&H REMOVE ARMORED CABLE THROUGH-OUT INTERIOR AND EXTERIOR OF BUILDING | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | DEFECTIVE KITCHEN FAUCET AT KITCHEN SINK | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
PRV DISCHARGE PIPE FROM PRV | HOT WATER TANK T&P VALVE HAS NO EXTENDING PIPE CONNECTION TO SAFE PAN | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |
PROVIDE AIR CHAMERS | LAUNDRY POTABLE WATER CONNECTIONS HAS NO AIR CHAMBERS OR ARESTORS | 5424 S KENNETH AVE | COMPLAINT | FAILED | View |