The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | 2 STORY REAR PORCH WITH IMPROPER FOOTINGS,STRINGERS NOT PROPERLY ATTACHED,USSING SINGLE 2X8 FOR BEAMS,COLUMNS NOT PROPERLY CONNECTED,COLUMNS ARE FIRE CUT WITH RIM JOIST CUT ABOVE THEM,GUARD AND HAND RAILS NOT PROPERLY BUILT WITH SOME BROKEN PICKETS-----PLANS AND PERMIT REQUIRRED | 845 W 51ST PL | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 1ST FLOOR FRONT DOOR MISSING PEEPHOLE | 845 W 51ST PL | COMPLAINT | FAILED | View |
MICE/RODENTS | EVIDENCE OF MICE IN 1ST FLOOR | 845 W 51ST PL | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERS ID POSTED | 845 W 51ST PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIRS-(NORTH) LEDGER IS ONLY NAILED INTO THE BUILDING. EDGE BEAM/RIM JOISTS ARE ONLY NAILED INTO THE COLUMN CONNECTIONS. STRINGERS ARE OVERCUT; ONLY 3 1/2 INCHES OF STRINGER DEPTH; ONLY NAILED INTO COLUMN AND TOE NAILED INTO DECK JOIST CONNECTIONS. UNDERSIZED, 2X4 JOIST HANGERS FOR 2X8 DECK JOISTS. RAILS ARE ONLY TOE NAILED INTO THE COLUMN/BUILDING CONNECTIONS. (SOUTH) COLUMNS ARE SET IN CONCRETE PIERS; FOUNDATION STATUS IS UNKNOWN. COLUMNS ARE OVERCUT AT 24 INCH SPLICES/LAP JOINTS; ONLY TOE NAILED WITH ONLY TWO BOLTS. LEDGERS ARE ONLY NAILED INTO THE BUILDING CONNECTIONS. EDGE BEAMS/RIM JOISTS ARE ONLY NAILED INTO THE COLUMNS. UNDERSIZED 2X4 JOIST HANGERS FOR 2X8 DECK JOISTS. STRINGERS ARE ONLY NAILED INTO COLUMN/DECK JOIST CONNECTIONS. STRINGERS FROM (GRADE) TO (1) ARE OVERCUT; ONLY 3 INCH STRINGER DEPTH. NORTH STRINGER FROM (1) TO (2) IS FRACTURED; ONLY NAILED INTO THE LEDGER. NEWEL POSTS ARE ONLY NAILED INTO THE HEADER BEAM WITH SOME SEPERATION AT THE CONNECTIONS. LOOSE HANDRAILS. GUARDRAILS SHIFT UPON LOAD. RAILS ARE ONLY TOE NAILED INTO THE COLUMNS WITH SOME SEPERATION AT THE CONNECTIONS. PLANS AND PERMIT REQUIRED FOR REPAIRS TO BOTH PORCHES. | 845 W 51ST PL | COMPLAINT | FAILED | View |
PROVIDE | TENANT DOORBELL-MISSING (SEC. 7-28-060). | 845 W 51ST PL | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN-NOT POSTED. | 845 W 51ST PL | COMPLAINT | FAILED | View |
OBTAIN OR POST PERMIT | 845 W 51ST PL | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 845 W 51ST PL | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 845 W 51ST PL | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 845 W 51ST PL | COMPLAINT | CLOSED | View | |
INSTALL DOOR VIEWING DEVICE | VIEWING DEVICES-MISSING. | 845 W 51ST PL | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS-MISSING. | 845 W 51ST PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED DETECTORS AND CONDITIONS. | 845 W 51ST PL | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW PANE-BROKEN. | 845 W 51ST PL | COMPLAINT | FAILED | View |
WATCHMAN | 845 W 51ST PL | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 845 W 51ST PL | COMPLAINT | CLOSED | View | |
REPAIR EXTERIOR WALL | EAST WALL BULGING OUTWARD TOWARD REAR OF BUILDING AT GRADE AND BELOW 2ND FLOOR WINDOW. WEST WALL TOWARD FRONT OF BUILDING AT GRADE. | 845 W 51ST PL | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | FRONT PORCH STRINGER UNATTACHED FROM 1ST FLOOR LANDING. MISSING/ BROKEN PICKETS. NO VISIBLE FOOTINGS, FOUNDATION IS UNKNOWN. LOOSE HANDRAIL. INSPECTOR POSTED D&H STICKER ON PORCH ON 4/26/23 @11:30 AM | 845 W 51ST PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY OPEN WOOD PORCH- BROKEN/ MISSING PICKETS. INCORRECT LAP JOINTS. NO STRUCTURAL HARDWARE. STRINGERS ATTACHED INCCORECTLY. STAIRS ARE WEAK AND LOOSE FROM GRADE TO 1ST FLOOR. HANDRAILS ARE LOOSE. | 845 W 51ST PL | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS ARE REQUIRED FOR FRONT AND REAR PORCH. | 845 W 51ST PL | COMPLAINT | FAILED | View |
BOARD AND SECURE RESIDTL BLDG | BUILDING IS VACANT AND BOARDED WITH PLYWOOD. NO ENTRY TO INTERIOR. | 845 W 51ST PL | COMPLAINT | FAILED | View |