Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 12:06 PM
PIN: 20234070180000
Property Address: 6824 S HARPER AVE
City - Zip: CHICAGO - 60637
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70070
2023 Tax District: 70131
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 16 Violations
Violation Inspector Comments Address Category Status View
CHIMNEY SOUTH ELEVATION /CHIMNEY X2 - FALLING, LOOSE, SPALLING, MISSING BRICK WITH WASHED OUT MORTAR;MASONRY PERMIT REQUIRED; 6824 S HARPER AVE COMPLAINT FAILED View
REPAIR ROOF REAR ELEVATION /ROLLED ROOF PRODUCT - PEELED BACK FROM ENCLOSED PORCH BACK TO MAIN BUILDING, LAYING ON ROOF; ROOF HATCH - MISSING; 6824 S HARPER AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; 6824 S HARPER AVE COMPLAINT FAILED View
REPAIR AREAWAY WALL SOUTH ELEVATION /AREAWAY CEILING - HOLES, LOOSE, MISSING PLASTER; HAND RAILS - LOOSE, BROKEN; 6824 S HARPER AVE COMPLAINT FAILED View
CHIMNEY CAPPING SOUTH ELEVATION /CHIMNEY CAPPING X2 - LOOSE, WASHED OUT MORTAR; 6824 S HARPER AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS FRONT ELEVATION /STONE WINDOW SILLS - WASHED OUT MORTAR; 6824 S HARPER AVE COMPLAINT FAILED View
PARAPET & COPING FRONT, NORTH, SOUTH ELEVATION /PARAPET AND COPING - SPALLING, LOOSE, MISSING, FALLING BRICK WITH WASHED OUT MORTAR;MASONRY PERMIT REQUIRED; 6824 S HARPER AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT, NORTH, SOUTH ELEVATION /EXTERIOR WALL - FRACTURED, SPALLING BRICK, WITH WASHED OUT MORTAR; FRONT ELEVATION /EXTERIOR [WING] WALL - TOP STONE CAPPING - WASHED OUT MORTAR, SHIFTED BRICK, WITH WASHED OUT MORTAR; SOUTH ELEVATION [AT AREAWAY] CHIMNEY [CLEAN-OUT] DOOR - MISSING; MASONRY PERMIT REQUIRED; 6824 S HARPER AVE COMPLAINT FAILED View
REPAIR LINTELS FRONT ELEVATION /ENTRY DOOR METAL LINTEL - RUSTED; 6824 S HARPER AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE NORTH ELEVATION [AT REAR] /PILE OF BRICKS [FROM FALLING PARAPET WALL]; SOUTH ELEVATION [AT REAR AREAWAY] PILE OF BRICKS [FROM FALLING CHIMNEY]; SOUTH ELEVATION [AT GRADE -CHIMNEY DOOR MISSING] CHIMNEY FILLED WITH DEBRIS; 6824 S HARPER AVE COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS REAR YARD / WEEDS - 12 INCH UP TO 16 INCH; 6824 S HARPER AVE COMPLAINT FAILED View
REPAIR FENCE REAR YARD /4 FEET SCREEN FENCE - TOP AND BOTTOM RAIL - MISSING; 6824 S HARPER AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE /NORTH AND SOUTH ELEVATION - PARAPET WALL - WASHED OUT MORTAR; NORHT ELEVATION /EXTERIOR WALL - WASHED OUT MORTAR; OVER-HEAD DOOR - PLYWOOD - ROTTED; 6824 S HARPER AVE COMPLAINT FAILED View
REPAIR GUTTER REAR ELEVATION /GUTTER - LOOSE, DETACHED FROM EAVE, LAYING ON ROOF; 6824 S HARPER AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 2 STORY WOOD PORCH WITH ROOF AND ENCLOSED 2 STORY PORCH;FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES; FOUNDATION STATUS UNKNOWN; FOUNDATIONS /BASES FORMED BY CONCRETE POURED IN AROUND COLUMN; FOUNDATION STATUS UNKNOWN;COLUMNS /6X6 COLUMNS STACKED UP ON TOP OF ONE ANOTHER [AT ROOF], FASTENED WITH NAILS ONLY; COLUMNS /INADEQUATE HALF-LAP JOINTS WITH OVERLAP OF ONLY 6 INCHES, WITH ONLY 2 BOLT USED OF 3/8 INCHES IN DIAMETER, SCAB BLOCKING; COLUMNS /OVER NOTCHED WITH FIRE CUTS AND RIM JOISTS CONNECTIONS OCCURRING AT THE SAME LOCATION OR IN CLOSE PROXIMITY AND ONLY 4 INCHES APART; ROOF BEAMS /FASTENED TO 6X6 COLUMN WITH NAILS/SCREWS ONLY;DECK JOISTS /UNDERSIZED 2X8 DECK JOISTS SPAN 9 FEET 8 INCHES; SPACED UP TO 22 INCHES O.C. (APART); SCABBED;STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STAIRS /RISER HEIGHT NOT UNIFORMED, RANGING FROM 6 1/2 INCHES TO 8 3/4 INCHES; TREADS /NOT UNIFORMED, RANGING FROM 8 INCHES TO 10 1/4 INCHES; NOSING - MISSING;RAILINGS /ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY; PICKETS SPACED UP TO 5 1/2 INCHES APART; GRADE TO BASEMENT /METAL GUARD RAIL ONLY 36 INCHES HIGH - ARE OF LADDER TYPE DESIGN, WITH HORIZONTAL TIES SPACED UP TO 16 INCHES APART; REAR 2 STORY WOOD ENCLOSED PORCH; UNABLE TO INSPECT FOOTINGS, FOUNDATION STATUS UNKNOWN; UNABLE TO INSPECT INTERIOR, CONDITION UNKNOWN;NORTH ELEVATION [AT 2ND. FL.] EXTERIOR [FRAME] WALL - DETACHED FROM EXTERIOR [MANONRY] WALL, GAPS UP TO 3 INCHES; REAR ELEVATION /EXTERIOR [FRAME] WALL - OUT OF PLUMB, LEANING OUTWARD;PLANS AND PERMIT REQUIRED FOR: REAR 2 STORY WOOD PORCH WITH ROOF AND ENCLOSED 2 STORY PORCH; ROOF CONNECTION MUST BE INCLUDED ON PLANS; 6824 S HARPER AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING ¿ NO RESPONSE;UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY; UNABLE TO INSPECT INTERIOR 2 STORY WOOD ENCLOSED PORCH; 6824 S HARPER AVE COMPLAINT FAILED View