Chicago Building Violations Data: 56 Violations
Violation Inspector Comments Address Category Status View
EGRESS ATTIC HAS ONE EXIT. 2824 W 22ND PL COMPLAINT PASSED View
ATTIC, DISCONTINUE ATTIC ALTERED INTO ONE DWELLING UNIT. 2824 W 22ND PL COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# OWNER'S I.D. SIGN NOT POSTED 2824 W 22ND PL COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING REFUSED ENTRY UNVERIFIED DETECTOR CONDITION AND OCCUPANCY. ORANGE STICKER POSTED 2824 W 22ND PL COMPLAINT PASSED View
SCREEN OUTER DOORS, WINDOWS EAST ELEVATION AT GRADE WINDOW TORN SCREEN 2824 W 22ND PL COMPLAINT PASSED View
CHIMNEY CAPPING CHIMNEY WALL MISSING CAP. 2824 W 22ND PL COMPLAINT PASSED View
REPAIR FENCE FRONT CHAIN LINK GATE BROKEN HINGES. 2824 W 22ND PL COMPLAINT PASSED View
INSTALL DOOR VIEWING DEVICE ALL APARTMENT ENTRY DOOR MISSING VIEWING DEVICE 2824 W 22ND PL COMPLAINT PASSED View
DEBRIS, EXCESSIVE REAR ENCLOSED PORCH FULL OF HOUSEHOLD MATERIALS - TOYS, TABLE, CHAIRS, CONSTRUCTION TOOLS 2824 W 22ND PL COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY REAR ENCLOSED PORCH OBSTRUCTION OF EXIT, TABLE/CHAIRS, STORAGE OF HOUSEHOLD MATERIAL 2824 W 22ND PL COMPLAINT PASSED View
SEPARATION OF DWELLING ATTIC WALL PARTITION DOES NOT PROVIDE FOR ONE HOUR FIRE SEPARATION 2824 W 22ND PL COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND PERMIT FOR ATTIC CONVERSION. 2824 W 22ND PL COMPLAINT PASSED View
INSTALL VENT PIPE FOR TRAP VENT KITCHEN SINK AND LAVATORY 1ST FLOOR LAVATORY - BASEMENT ALSO KITCHEN SINK BASEMENT 2824 W 22ND PL COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE PVC SUPPLIES WATER CLOSET AND LAVATORY 2824 W 22ND PL COMPLAINT PASSED View
OBTAIN PERMIT FOR PLUMBING TO CORRECT ALL PLUMBING VIOLATIONS. 2824 W 22ND PL COMPLAINT PASSED View
PROVIDE AIR CHAMERS PROVIDE AIR CHAMBERS AT KITCHEN SINK 1ST FLOOR ALSO WASH MACHINE 2ND FLOOR PORCH. 2824 W 22ND PL COMPLAINT PASSED View
REPAIR DEFECTIVE FITTINGS FLEXIBLE CONNECTIONS AT WATER HEATER-BASEMENT 2824 W 22ND PL COMPLAINT PASSED View
ENGAG LIC & BOND PLMBNG CNTRC A LICENSED AND BONDED PLUMBING CONTRACTOR IS REQUIRED 2824 W 22ND PL COMPLAINT PASSED View
REPLACE DEFECTIVE WASTE PIPING P-TRAP UNDER LAVATORY - BASEMENT 2824 W 22ND PL COMPLAINT PASSED View
INSTALL FIXTURES PROPERLY HARD PIPE GAS AT BASEMENT WATER HEATER. ALSO AT ATTIC WATER HEATERS. 2824 W 22ND PL COMPLAINT PASSED View
INSTALL INDIRECT SANT. WASTE PROVIDE A FLOOR DRAIN AT BASEMENT WATER-HEATER TO CONVEY THE DISCHARGE FROM RELIEF VALVE. (18-29-504.7.1.) AS PER CODE. ALSO AT ATTIC WATER HEATERS. 2824 W 22ND PL COMPLAINT PASSED View
INSTALL TRAP,WASTE,VENT PIPES PROPERLY TRAP AND VENT WASH MACHINE 2ND FLOOR. 2824 W 22ND PL COMPLAINT PASSED View
REPLACE DEFECTIVE SOIL PIPING REPAIR HOLES IN CAST IRON STACK - ATTIC CEILING. PROTECT PIPES FROM FREEZING AT 2ND FLOOR PORCH. 2824 W 22ND PL COMPLAINT PASSED View
REPLACE DEFECTIVE FAUCET PROVIDE A SEPARATE COLD WATER LINE TO WATER CLOSET 2824 W 22ND PL COMPLAINT PASSED View
RMV PLBFIX INSTALLD W/0 PERMIT REMOVE ALL PLUMBING FIXTURES AND RELATED PIPING AT ATTIC SPACE 2824 W 22ND PL COMPLAINT PASSED View
ADD RECEPTACLES ADD RECEPTACLES TO EASE EXTENSIONS CORD USE IN BASEMENT 1, 2ND FLOOR UNITS - BEDROOMS, LIVING ROOMS, KITCHEN AREA'S -- 2824 W 22ND PL COMPLAINT PASSED View
SEE INSPECTOR COMMENTS (18-27-210.8) PROVIDE GFCI PROTECTION FOR KICHEN COUNTER TOP AREA'S AND BATHROOM OF BASEMENT 1, 2 FLOOR UNITS - FRONT BUILDING 2824 W 22ND PL COMPLAINT PASSED View
(18-27-110.11) CONDUCTORS AND ELECTRICAL EQUIPMENT SHALL BE SUITABLE FOR THE LOCATION AND TEMPERATURE - CEILING FANS NOT APPROVE FOR BATHROOM USE - FRONT BUILDING BASEMENT, 1, 3 FLOOR UNITS -- 2824 W 22ND PL COMPLAINT PASSED View
GROUNDING RECEPTACLES PROVIDE GROUNDING TYPE RECEPTACLES IN BASEMENT, 1 2 FLOOR UNITS - FRONT BUILDING - 2824 W 22ND PL COMPLAINT PASSED View
ARMORED CABLE REMOVE ARMORED CABLE THROUGH OUT PORCH AREA'S - FRONT BUILDING -- 2824 W 22ND PL COMPLAINT PASSED View
EXPOSED WIRING REMOVE EXPOSE WIRING 2ND FLOOR FRONT HALL STAIRS -- 2824 W 22ND PL COMPLAINT PASSED View
NO PERMIT WIRING PROVIDE PLANS AND PERMITS FOR INSTALLATION OF ELECTRICAL WIRING, CONDUIT, BOXES, FITTINGS AND ELECTRICAL EQUIPMENT - ATTIC SPACE -- FRONT BUILDING AND REAR BUILDING BASEMENT UNIT -- 2824 W 22ND PL COMPLAINT PASSED View
(13-12-380) PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL WIRING, CONDUIT, BOXES, FITTINGS AND ELECTRICAL EQUIPMENT THROUGH OUT ATTIC SPACE -- FRONT BUILDING AND REAR BUILDING BASEMENT UNIT -- 2824 W 22ND PL COMPLAINT PASSED View
CONTRARY TO ORIGINAL PLAN REAR BUILDING BASEMENT STORAGE AREA HAS BEEN CONVERTED TO A FAMILY UNIT. 2824 W 22ND PL COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR REAR BUILDING BASEMENT PLANS AND PERMIT FOR THE DECONVERSION 2824 W 22ND PL COMPLAINT PASSED View
WORK NOT ALLOWED REAR BUILDING BASEMENT: RESTORE SPACE TO ITS ORIGINAL CONFIGURATION. 2824 W 22ND PL COMPLAINT PASSED View
SEPARATION OF DWELLING ADEQUAT REAR BUILDING BASEMENT PARTITION WALLS DOES NOT PROVIDE FOR 1 HOUR FIRE SEPARATION 2824 W 22ND PL COMPLAINT PASSED View
CEILING HEIGHT - 7' - BASEMENT REAR BUILDING BASEMENT DWELLING UNIT CEILING HEIGHT IS 6'4" 7 FEET IS CODE REQUIREMENT. 2824 W 22ND PL COMPLAINT PASSED View
INSTALL SMOKE DETECTORS REAR BUILDING BASEMENT DWELLING UNIT AREA MISSING SMOKE DETECTOR. 2824 W 22ND PL COMPLAINT PASSED View
CARB MONOX DETECT IN RESID REAR BUILDING BASEMENT DWELLING UNIT AREA MISSING CARBON MONOXIDE 2824 W 22ND PL COMPLAINT PASSED View
REPAIR DEFECTIVE FITTINGS FLEXIBLE CONNECTIONS AT WATER HEATER BASEMENT. 2824 W 22ND PL COMPLAINT PASSED View
INSTALL INDIRECT SANT. WASTE REAR BUILDING PROVIDE A FLOOR DRAIN NEAR (2) WATER HEATERS IN BASEMENT TO CONVEY THE DISCHARGE FROM RELIEF VALVE. (18-29-504.7.1 AS PER CODE. 2824 W 22ND PL COMPLAINT PASSED View
INSTALL VENT PIPE FOR TRAP REAR BUILDING VENT LAVATORY AND KITCHEN SINK. 2824 W 22ND PL COMPLAINT PASSED View
REPAIR OR REPLACE (18-29-502.6) REAR BUILDING LOCATION OF WATER HEATERS AT BASEMENT UNIT. MUST ALLOW ROOM TO REMOVE OR REPLACE WATER HEATERS. 2824 W 22ND PL COMPLAINT PASSED View
OBTAIN PERMIT FOR PLUMBING REAR BUILDING TO CORRECT ALL PLUMBING VIOLATIONS. 2824 W 22ND PL COMPLAINT PASSED View
ENGAG LIC & BOND PLMBNG CNTRC REAR BUILDING A LICENSED AND BONDED PLUMBING CONTRACTOR IS REQUIRED 2824 W 22ND PL COMPLAINT PASSED View
SEE INSPECTOR COMMENTS (18-27-210.8) REAR BUILDING PROVIDE GFCI PROTECTION FOR 2ND FLOOR UNIT REAR BUILDING KITCHEN COUNTER TOP AREA AND BATHROOM 2824 W 22ND PL COMPLAINT PASSED View
DEFECTIVE FIXTURES REAR BUILDING REPLACE DEFECTIVE LIGHT FIXTURE 2ND FLOOR REAR BUILDING KITCHEN AREA - 2824 W 22ND PL COMPLAINT PASSED View
DEFECTIVE LIGHTING SERVICE DETERIORATED CABLES AT SERVICE HEAD AND SERVICE ENTRANCE CABLE INSULATION IS FRAYED -- FRONT BUILDING -- 2824 W 22ND PL COMPLAINT FAILED View
REPAIR**************** (18-27-230.70) THE LOCATION OF THE SERVICE DISCONNECT SHALL BE IN THE BASEMENT OR 1ST FLOOR WITHIN THE BUILDING NOT MORE THAN 5' FROM POINT OF ENTRY -- FRONT BUILDING -- 2824 W 22ND PL COMPLAINT FAILED View
REMOVE************** (18-27-210.25) PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE 2824 W 22ND PL COMPLAINT FAILED View
(18-27-210.25) REAR BUILDING PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE -- 2824 W 22ND PL COMPLAINT PASSED View
WORKING SPACE PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANELS -- FRONT BUILDING 2824 W 22ND PL COMPLAINT PASSED View
CONNECT GAS APPLIANCE TO VENT OPEN FLUE PIPE ATTIC 2824 W 22ND PL COMPLAINT PASSED View
OPEN (18-29-504.8) PROVIDE DRIP PANS UNDER EACH WATER HEATERS ATTIC SPACE AS PER CODE. 2824 W 22ND PL COMPLAINT PASSED View
(13-12-380) PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL WIRING, CONDUIT, BOXES, FITTINGS, AND ELECTRICAL EQUIPMENT THROUGH OUT ATTIC SPACE -- FRONT BUILDING AND REAR BUILDING BASEMENT UNIT -- 2824 W 22ND PL COMPLAINT FAILED View