Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 7:14 AM
PIN: 16261050680000
Property Address: 2340 S LAWNDALE AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77115
2023 Tax District: 77079
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 41 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# (SR#07-00380494) BUILDING OWNER'S ID SIGN NOT POSTED 2340 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST ELEVATION, REAR PORCH: 6X6 COLUMNS BEAR ON CONCRETE SLAB; FOOTINGS ARE MISSING; INADEQUATE BEAM TO COLUMN CONNECTION AT GRADE; LEDGER BOARD IS ATTACHED TO EXTERIOR WALL WITH NAILS ONLY; UNDERSIZED 2X6 JOISTS ARE USED OVER 11 FT. SPAN; STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMNS; STAIRS ARE OF AN OPEN RISER DESIGN; ALL TREADS ARE LOOSE AND SPRINGY; BOTTOM RISERS ON ALL LEVELS EXCEED 8 INCHES; RAILS ARE MISSING ON 3RD FLOOR AT GABLE END OF ROOF; PICKETS ARE MORE THAN 4" APART; PICKET ON 1ST LEVEL IS BROKEN; GAPS IN DECKBOARDS ON 3RD LEVEL; SUBMIT PLANS AND OBTAIN PERMITS FOR REPAIRS 2340 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRAME WEST ELEVATION: GAPS AROUND 1ST FLOOR AND BASEMENT REAR DOORS; NORTH ELEVATION: GAPS AROUND UTILITY ROOM DOOR (INSIDE); SOUTH ELEVATION: GAPS AROUND DOOR FRAME 2340 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR EAVES WEST ELEVATION: FLASHING MISSING ON RAKE BOARDS AND SOFFITS; SOUTH ELEVATION: ROTTING PLYWOOD AT VENT PIPE ON ROOF (SEC. 7-28-060) 2340 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR OR REPLACE DOWNSPOUT DISCONNECTED -SOUTH, DOWNSPOUT MISSING-NORTH (SEC. 18-29-1101.2.1) 2340 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH, NORTH ELEVATIONS: OPEN MORTAR JOINTS IN EXTERIOR WALL 2340 S LAWNDALE AVE COMPLAINT FAILED View
CHIMNEY WEST ELEVATION: OPEN MORTAR JOINTS AT CHIMNEY 2340 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR WEST, EAST ELEVATION: HANDRAILS MISSING AT BASEMENT STAIRS; EAST ELEVATION: CONCRETE STAIRS AT BASEMENT ARE CRACKED, SPALLED 2340 S LAWNDALE AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH WEST ELEVATION: GUARDRAIL MISSING AT BASEMENT 2340 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION WEST ELEVATION: FOUNDATION WALL IS CRACKED AT GRADE (NEAR BASEMENT DOOR); EAST ELEVATION: FOUNDATION WALL IS CRACKED AND BROKEN UP AT BASEMENT. WORK IN PROGRESS, BUT NO PERMIT IS DISPLAYED; OBTAIN PERMIT FOR REPAIRS 2340 S LAWNDALE AVE COMPLAINT FAILED View
WORKING ON STOP WORK ORDER FOUNDATION WORK ON EAST AND WEST ELEVATIONS 2340 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR NORTH ELEVATION, UTILITY ROOM: ROTTING SHEET OF PLYWOOD BEING USED AS A DOOR. DOOR HEIGHT IS LESS THAN 6 FEET 8 INCHES 2340 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE NORTH ELEVATION, UTILITY ROOM: LOCK ON "PLYWOOD" DOOR DOES NOT ENGAGE 2340 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM UTILITY ROOM (NORTH) AND INTERIOR STAIRWELLS: HANDRAILS ARE MISSING 2340 S LAWNDALE AVE COMPLAINT FAILED View
SELF-CLOSE CLASS B FIRE DOOR INTERIOR" CLOSERS MISSING ON ENTRANCE DOORS 2340 S LAWNDALE AVE COMPLAINT FAILED View
FIRE EXTNGSHR REQ, RESDNTL INTERIOR: FIRE EXTINGUISHERS ARE MISSING ON ALL FLOORS 2340 S LAWNDALE AVE COMPLAINT FAILED View
INSTALL DEAD BOLT LOCK INTERIOR: DEADBOLTS ARE MISSING ON ENTRANCE DOORS AT 202 AND 302 2340 S LAWNDALE AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE INTERIOR: VIEWING DEVICE MISSING ON APARTMENT 301 2340 S LAWNDALE AVE COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT UTILITY ROOM: DRYWALL IS UNFINISHED 2340 S LAWNDALE AVE COMPLAINT FAILED View
INSTALL COVERS UTILITY ROOM: COVERS ARE MISSING ON OUTLETS, SWITCHES 2340 S LAWNDALE AVE COMPLAINT FAILED View
SUPPORT FIXTURES UTILITY ROOM: CEILING LIGHT FIXTURE IS HANGING 2340 S LAWNDALE AVE COMPLAINT FAILED View
WORK NOT ALLOWED ATTIC: REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE ATTIC WITHOUT A PERMIT 2340 S LAWNDALE AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE 2340 S LAWNDALE AVE COMPLAINT FAILED View
ATTIC, DISCONTINUE ATTIC: DISCONTINUE USE OF ATTIC FOR LIVING QUARTERS 2340 S LAWNDALE AVE COMPLAINT FAILED View
CEILING HEIGHT - 7' ATTIC: CEILING HEIGHT IS LESS THAN 7 FEET 2340 S LAWNDALE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY INTO BASEMENT. UNABLE TO INSPECT-UNVERIFIED DETECTORS OR OCCUPANCY 2340 S LAWNDALE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID ATTIC: CARBON MONOXIDE DETECTOR IS MISSING 2340 S LAWNDALE AVE COMPLAINT FAILED View
OPEN SEE COMENTS 2340 S LAWNDALE AVE PERMIT PASSED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED FROM 2007 THRU 2012. 2340 S LAWNDALE AVE PERIODIC FAILED View
NO KEY TO USE EXIT DOOR EAST ELEVATION FRONT GATE DOUBLE KEY LOCK. 2340 S LAWNDALE AVE PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY WEST ELEVATION BACK GATE PADLOCKED. 2340 S LAWNDALE AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE/ENTRY AT TIME OF INSPECTION TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2012 ANNUAL INSPECTION. 2340 S LAWNDALE AVE PERIODIC FAILED View
REPAIR EXTERIOR STAIR EAST AND WEST ELEVATION BASEMENT STAIRWELLS MISSING HANDRAILS. 2340 S LAWNDALE AVE PERIODIC FAILED View
REPAIR EXTERIOR STAIR EAST AND WEST ELEVATION BASEMENT STAIRWELLS MISSING HANDRAILS. 2340 S LAWNDALE AVE PERIODIC FAILED View
ARRANGE FOR RE-INSPECTION NO PLANS,PERMIT FOR 8 A/C UNITS 2340 S LAWNDALE AVE PERMIT PASSED View
CONNECT DOWNSPOUT TO SEWER NORTH AND SOUTHEAST -GRADE DOWNSPOUTS DRAINING INTO PUBLIC WAY. 2340 S LAWNDALE AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF LEAKING CEILING IN LIVING ROOM ON 2ND FLOOR.UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2017 ANNUAL INSPECTION. 2340 S LAWNDALE AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S I.D SIGN POSTED. 2340 S LAWNDALE AVE PERIODIC FAILED View
NO KEY TO USE EXIT DOOR FRONT AND BACK GATES DOUBLE KEY LOCKED. 2340 S LAWNDALE AVE PERIODIC FAILED View
INSTALL EXIT SIGN INTERIOR: EXIT SIGNS ARE MISSING ON ALL FLOORS 2340 S LAWNDALE AVE COMPLAINT FAILED View
OPEN 2340 S LAWNDALE AVE PERMIT PASSED View