Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | (SR#07-00380494) BUILDING OWNER'S ID SIGN NOT POSTED | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION, REAR PORCH: 6X6 COLUMNS BEAR ON CONCRETE SLAB; FOOTINGS ARE MISSING; INADEQUATE BEAM TO COLUMN CONNECTION AT GRADE; LEDGER BOARD IS ATTACHED TO EXTERIOR WALL WITH NAILS ONLY; UNDERSIZED 2X6 JOISTS ARE USED OVER 11 FT. SPAN; STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMNS; STAIRS ARE OF AN OPEN RISER DESIGN; ALL TREADS ARE LOOSE AND SPRINGY; BOTTOM RISERS ON ALL LEVELS EXCEED 8 INCHES; RAILS ARE MISSING ON 3RD FLOOR AT GABLE END OF ROOF; PICKETS ARE MORE THAN 4" APART; PICKET ON 1ST LEVEL IS BROKEN; GAPS IN DECKBOARDS ON 3RD LEVEL; SUBMIT PLANS AND OBTAIN PERMITS FOR REPAIRS | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | WEST ELEVATION: GAPS AROUND 1ST FLOOR AND BASEMENT REAR DOORS; NORTH ELEVATION: GAPS AROUND UTILITY ROOM DOOR (INSIDE); SOUTH ELEVATION: GAPS AROUND DOOR FRAME | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | WEST ELEVATION: FLASHING MISSING ON RAKE BOARDS AND SOFFITS; SOUTH ELEVATION: ROTTING PLYWOOD AT VENT PIPE ON ROOF (SEC. 7-28-060) | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | DOWNSPOUT DISCONNECTED -SOUTH, DOWNSPOUT MISSING-NORTH (SEC. 18-29-1101.2.1) | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH, NORTH ELEVATIONS: OPEN MORTAR JOINTS IN EXTERIOR WALL | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
CHIMNEY | WEST ELEVATION: OPEN MORTAR JOINTS AT CHIMNEY | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST, EAST ELEVATION: HANDRAILS MISSING AT BASEMENT STAIRS; EAST ELEVATION: CONCRETE STAIRS AT BASEMENT ARE CRACKED, SPALLED | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | WEST ELEVATION: GUARDRAIL MISSING AT BASEMENT | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | WEST ELEVATION: FOUNDATION WALL IS CRACKED AT GRADE (NEAR BASEMENT DOOR); EAST ELEVATION: FOUNDATION WALL IS CRACKED AND BROKEN UP AT BASEMENT. WORK IN PROGRESS, BUT NO PERMIT IS DISPLAYED; OBTAIN PERMIT FOR REPAIRS | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
WORKING ON STOP WORK ORDER | FOUNDATION WORK ON EAST AND WEST ELEVATIONS | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | NORTH ELEVATION, UTILITY ROOM: ROTTING SHEET OF PLYWOOD BEING USED AS A DOOR. DOOR HEIGHT IS LESS THAN 6 FEET 8 INCHES | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | NORTH ELEVATION, UTILITY ROOM: LOCK ON "PLYWOOD" DOOR DOES NOT ENGAGE | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | UTILITY ROOM (NORTH) AND INTERIOR STAIRWELLS: HANDRAILS ARE MISSING | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
SELF-CLOSE CLASS B FIRE DOOR | INTERIOR" CLOSERS MISSING ON ENTRANCE DOORS | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | INTERIOR: FIRE EXTINGUISHERS ARE MISSING ON ALL FLOORS | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | INTERIOR: DEADBOLTS ARE MISSING ON ENTRANCE DOORS AT 202 AND 302 | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | INTERIOR: VIEWING DEVICE MISSING ON APARTMENT 301 | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | UTILITY ROOM: DRYWALL IS UNFINISHED | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | UTILITY ROOM: COVERS ARE MISSING ON OUTLETS, SWITCHES | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | UTILITY ROOM: CEILING LIGHT FIXTURE IS HANGING | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | ATTIC: REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE ATTIC WITHOUT A PERMIT | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
ATTIC, DISCONTINUE | ATTIC: DISCONTINUE USE OF ATTIC FOR LIVING QUARTERS | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' | ATTIC: CEILING HEIGHT IS LESS THAN 7 FEET | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY INTO BASEMENT. UNABLE TO INSPECT-UNVERIFIED DETECTORS OR OCCUPANCY | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | ATTIC: CARBON MONOXIDE DETECTOR IS MISSING | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
OPEN | SEE COMENTS | 2340 S LAWNDALE AVE | PERMIT | PASSED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2007 THRU 2012. | 2340 S LAWNDALE AVE | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | EAST ELEVATION FRONT GATE DOUBLE KEY LOCK. | 2340 S LAWNDALE AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | WEST ELEVATION BACK GATE PADLOCKED. | 2340 S LAWNDALE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE/ENTRY AT TIME OF INSPECTION TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2012 ANNUAL INSPECTION. | 2340 S LAWNDALE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | EAST AND WEST ELEVATION BASEMENT STAIRWELLS MISSING HANDRAILS. | 2340 S LAWNDALE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | EAST AND WEST ELEVATION BASEMENT STAIRWELLS MISSING HANDRAILS. | 2340 S LAWNDALE AVE | PERIODIC | FAILED | View |
ARRANGE FOR RE-INSPECTION | NO PLANS,PERMIT FOR 8 A/C UNITS | 2340 S LAWNDALE AVE | PERMIT | PASSED | View |
CONNECT DOWNSPOUT TO SEWER | NORTH AND SOUTHEAST -GRADE DOWNSPOUTS DRAINING INTO PUBLIC WAY. | 2340 S LAWNDALE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF LEAKING CEILING IN LIVING ROOM ON 2ND FLOOR.UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2017 ANNUAL INSPECTION. | 2340 S LAWNDALE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S I.D SIGN POSTED. | 2340 S LAWNDALE AVE | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT AND BACK GATES DOUBLE KEY LOCKED. | 2340 S LAWNDALE AVE | PERIODIC | FAILED | View |
INSTALL EXIT SIGN | INTERIOR: EXIT SIGNS ARE MISSING ON ALL FLOORS | 2340 S LAWNDALE AVE | COMPLAINT | FAILED | View |
OPEN | 2340 S LAWNDALE AVE | PERMIT | PASSED | View |