Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | WEST ELEVATION EXYERIOR STAIRS GRADE TO 1ST FLOOR,MISSING HAND RAILS. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | WEST ELEVATION REAR ENTRY DOOR,MISSING KNOB. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | WEST ELEVATION,SIDE ENTRY DOORS,FRONT AND REAR,BROKEN DOOR AND FRAME. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
EGRESS -BASEMENT | BASEMENT DWELLING UNIT-ONLY ONE EGRESS EXITS ( IN THE REAR ). | 1748 W 51ST ST | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT DWELLING UNIT CEILING HEIGHT IS 5 FOOT 10 INCHES. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO BASEMENT FRONT,1ST FLOOR FRONT,2ND,ATTIC,TO CHECK OCCUPANCY, DETECTORS. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR REAR UNIT,MISSING CARBON MONOXIDE DETECTOR. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | 1ST FLOOR REAR UNIT,KITCHEN OUTLET,DEFECTIVE. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | OBTAIN PERMIT TO REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRICAL) INSTALED IN THE BASEMENT WITH OUT A PERMIT. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | ALL 3 CHIMNEY CAPS MISSING. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF - ASPHALT ROLLED ROOFING TEARING AWAY WITH SECTIONS DETERIORATING. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION - ENCLOSED PORCH WALL DAMAGED, WRECKED, FRAMED WALL PUSHED-IN AND SIDING DETACHED FROM WALL. (PLANS AND PERMITS REQUIRED FOR REPAIRS). EAST ELEVATION - BUBBLED AND WAVY SIDING. SOUTHWEST CORNER - WOOD TRIM DETACHING FROM WALL. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION - CONCRETE STAIRS CRACKED, BROKEN AND PITTED. MISSING HANDRAIL SYSTEM. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | WEST ELEVATION; ALL 3 SIDE ENTRY DOOR'S - LOCKS BROKEN. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | FRONT OF BUILDING - IRON DOOR BROKEN AND FRAME CROOKED, MISSING ALL HARDWARE. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWELL, REAR ENCLOSED PORCH - TOP OF STAIRWELL, AND 2ND FLOOR FRONT APARTMENT - MISSING SMOKE DETECTORS. WEST INTERIOR STAIRWELL AND 2ND FLOOR REAR APARTMENT - DEFECTIVE SMOKE DETECTORS. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR FRONT APARTMENT - MISSING CARBON MONOXIDE DETECTOR. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
MICE/RODENTS | 2ND FLOOR, FRONT APARTMENT - INFESTED WITH RODENTS. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 2ND FLOOR, FRONT APARTMENT - HOLE ON KITCHEN CEILING WITH WATER STAINS. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | FRONT INTERIOR STAIRWELL - WATER STAINS ON CEILINGS AND WALLS. WEST SIDE INTERIOR STAIRWELL - PEELING PAINT AND PLASTER CRACKED AND BUBBLED. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT INTERIOR STAIRWELL AND REAR ENCLOSED PORCH; ACCUMULATION OF STORAGE ON STAIR LANDINGS - STORING BAGS OF CLOTHES AND BIKES. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | ATTIC DORMER BUILT, NO PERMIT OBTAINED. PLANS AND PERMITS ARE NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL FROM ALL TRADES. PLANS ARE TO INCLUDE REPAIRS FOR THE DAMAGES OF THE REAR ENCLOSED PORCH AND CORRECTIONS TO 4/10/2010 CSR # 100418024 - FOR ALTERATIONS TO BASEMENT, BASEMENT CONVERTED INTO AN APARTMENT. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | OBTAIN PERMIT TO REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBLING AND ELECTRICAL) INSTALLED IN THE BASEMENT AND ATTIC WITHOUT A PERMIT. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO ALL 1ST FLOOR UNITS, BASEMENT AND ATTIC, UNABLE TO VERIFY DETECTORS, INTERIOR CONDITIONS AND OCCUPANCY IN ATTIC AND BASEMENT. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 1ST FLOOR REAR APT./ HOT WATER IS SUPPLIED AT ONLY 50 DEGREES F. HOT WATER IS INSUFFICIENT. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR REAR APT.- MISSING SMOKE DETECTOR. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR REAR APT. - MISSING CARBON MONOXIDE DETECTOR. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | (18-29-705.1 THRU 16 REMOVE A;; SEWAGE RESIDUE | 1748 W 51ST ST | COMPLAINT | PASSED | View |
STOP ODORS RPR DFT SEWAGE SYS | 18-29-705.1) THRU 16 ) SEAL ALL OPEN SEWER CONNECTIONS | 1748 W 51ST ST | COMPLAINT | PASSED | View |
REPAIR ROOF | ROLLED ROOFING IS MISSING AND DRYROTTED IN VARIOUS LOCATIONS. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION ALUMINUM SIDING/WALL HAS AN EXTREME BULGE SHIFTING TOWARD ALLEY. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | WEST ELEVATION COMMON ENTRY DOOR MISSING KEYED ENTRY LOCK. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF LOOSE,WORN AND MISSING ROOFING MATERIAL,EXPOSED PLYWOOD SHEATHING. | 1748 W 51ST ST | COMPLAINT | CLOSED | View |
PROVIDE GUTTER & DOWNSPOUT | GUTTER AND DOWNSPOUTS MISSING AND DAMAGED SECTIONS. | 1748 W 51ST ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL LOOSE AND MISSING SECTIONS OF VINYL SIDING. | 1748 W 51ST ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR HARDWARE | EXTERIOR DOORS MISSING LOCKS,KNOBS AND VIEWING DEVICES. | 1748 W 51ST ST | COMPLAINT | CLOSED | View |
REPAIR ROOF | EAST ELEVATION- WATER LEAKS IN ATTIC. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 1ST FLOOR REAR APARTMENT LIVING ROOM 63 DEGREES DINNING ROOM 64 DEGREES. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR 1ST FLOOR APARTMENT NO SMOKE DETECTOR.BASEMENT NO SMOKE DETECTOR.REAR INTERIOR STAIRS2ND FLOOR NO SMOKE DETECTOR | 1748 W 51ST ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | REAR BASEMENT NO CARBON MONOXIDE. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | IST FLOOR REAR APARTMENT A EAST WINDOWS (4) PLASTIC ON TO STOP DRAFTS.REAR 2ND FLOOR REAR ENCLOSED PORCH 6" GAP AT BTTOM OF DOOR. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | REAR 1ST FLOOR APARTMENT FURNACE DOES NOT TURN ON. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER ID NOT POSTED. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | WEST ELEVATION - REAR BASEMENT NO DEAD BOLT. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | FRONT 2ND FLOOR NO VIEWING DEVICE. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | REAR ROOM 1ST FLOOR WATER DAMAGE AT CEILING.BASEMENT REAR CEILING WATER DAMAGE.ATTIC EAST ELEVATION WATER BUCKS USED TO STOP WATER FROM COME IN 2ND FLOOR APARTMENT.. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | REAR 1ST FLOOR APARTMENT KITCHEN FLOOR TILE LOOSE.REAR APARTMENT FLOORS ARE OUT OF LEVEL . | 1748 W 51ST ST | COMPLAINT | FAILED | View |
RATS | RAT TRAPS THROUGHOUT ALL FLOORS. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | EAST AND WEST ELEVATION HALF OF GUTTERS MISSING. EAST ELEVATION- REAR DOWNSPOUT 2 SECTIONS MISSING. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SIDING MISSING THROUGHOUT ALL ELEVATION. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | REAR STAIRS .GRADE TO BASEMENT MISSING HANDRAIL. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | WEST ELEVATION EXTERIOR STAIRS MISSING GUARD RAILS. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION - GRADE TO 1ST FLOOR NO HANDRAIL. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | ATTIC ADD ON BATHROOM WITH SHOWER.AT REAR ATTIC. EAST ELEVATION NEW DORMER 16X16 NO PERMIT AND NEW PARTIONSREMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING ELECTRICAL INSTALLED INATTIC WITHOUT A PERMIT. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | EAST ELEVATION - ATTIC .16X16 NEW DORMER.ATTIC 1/2 BATH ADD ON AT REAR ATTIC WITH NEW WALLS. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZED ALTERATIONS TO ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 1ST FLOOR REAR - USING COOKING GAS FOR HEAT.(11:30AM). | 1748 W 51ST ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 2ND FLOOR FRONT 47 DEGREES IN APARTMENT,2ND FLOOR REAR 39 DEGREES THROUGHOUT ENTRIRE APARTMENT AND 1ST FLOOR REAR 64 DEGREES IN KITCHEN (11:20PM). | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 2ND FLOOR REAR - SMOKE DETECTOR - OUT OF SERVICE. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR REAR - SMOKE DETECTOR - MISSING. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR REAR - CARBON MONOXIDE DETECTOR - MISSING. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 2ND FLOOR FRONT AND REAR AND 1ST FLOOR REAR NO RUNNING HOT WATER. (11:20AM). | 1748 W 51ST ST | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | 2NF FLOOR FRONT AND REAR,1ST FLOOR REAR - NO RUNNING WATER.(11:20AM). | 1748 W 51ST ST | COMPLAINT | FAILED | View |
ROACHES | 2ND FLOOR, FRONT AND REAR APARTMENTS - INFESTED WITH ROACHES. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED ON BUILDING. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 1ST FLOOR REAR APT./ ROOM TEMPERATURES 58 DEGREES TO 60 DEGREES F. AT 9:25 AM.HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPLACE HOUSE DRAIN PIPING | 11-16-020) (18-29-301.3) | 1748 W 51ST ST | COMPLAINT | PASSED | View |
REMOVE | (7-28-060)1FT OF WATER IN BASEMENT. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
REPAIR GUTTER | EAST AND WEST ELEVATION GUTTERS HAVE MISSING SECTIONS. | 1748 W 51ST ST | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | OPEN JUNCTION BOX EXPOSED WIRING UNDER-NEATH THE REAR ENCLOSED PORCH.DANGEROUS AND HAZADROUS CONDITION. | 1748 W 51ST ST | COMPLAINT | CLOSED | View |
ROACHES | REAR 1ST FLOOR APARTMENT ROACHES IN KITCHEN. | 1748 W 51ST ST | COMPLAINT | FAILED | View |