Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OBSTRUCTIONS IN EXIT WAY | REAR GATE LOCKED KEY TO EXIT. | 936 W 76TH ST | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | EXPOSED WOOD TRIM CHIPPED PAINT. | 936 W 76TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH INADEQUATE BEAM COLUMN CONNECTION. | 936 W 76TH ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | TEMP IN APARTMENTS RANGE FROM 63 DEGREES F TO 67 DEGREES F, COLDER IN REAR BEDROOMS IN APARTMENT 944, 2ND FLOOR, AND 942, 2ND FLOOR RADIATORS ARE COLD | 936 W 76TH ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY MISSING CAP | 936 W 76TH ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | LINTEL SAGGING WASHOUT MORTAR REQUIRE PERMIT | 936 W 76TH ST | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 936 1ST FLOOR TENANT USING COOKING STOVE FOR HEAT. | 936 W 76TH ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 936 1ST FLOOR- TEMP 60 RADIATORS COLD. | 936 W 76TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 936 1ST FLOOR - NO SMOKE DETECTOR. | 936 W 76TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WALLS BULGING WASHOUT MORTAR,REQUIRE PERMIT,SOUTH AND EAST | 936 W 76TH ST | COMPLAINT | FAILED | View |
PARAPET | WALLS BULGING WASOUT MORTAR REQUIRE PERMIT | 936 W 76TH ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | MILDREW AND MOLDED THRU-OUT | 936 W 76TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | APT1 AND STAIRWAY NO SMOKE DETECTOR | 936 W 76TH ST | COMPLAINT | FAILED | View |
STOP LEAKING WATER | LEAKAGE AROUND WINDOWS | 936 W 76TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | 2 REAR CONCRETE BASEMENT ACCESS STAIRS- GRADE DOWN TO BASEMENT-(1) LADDER-TYPE GUARDRAILS AT ONLY 36 INCHES HIGH (2) WEAK WOOD HANDRAILS (3) 936-38 REAR BASEMENT STAIR-CRACKED UNEVEN CONCRETE HITCH 12 INCH TOP RISER (4) 942-44 REAR BASEMENT STAIR-CRACKED UNEVEN CONCRETE WITH 3 INCH TOP RISER AND 13 INCH TOP TREAD DEPTH | 936 W 76TH ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | TWO STORY REAR OPEN WOOD PORCHES-(1) COLUMNS SIT DIRECTLY DIRECTLY ON CONCRETE CYLINDER THAT BEAR ON TOP OF CONCRETE SLAB WITH UNKNOWN FOUNDATIONS (2) UNSTABLE CONNECTIONS-COLUMN TO BEAMS FIRE-CUT WITH POST CONSTRUCTION FLATE-PLATE CONNECTORS (3) FACENAILED AND TOE NAILED CONNECTIONS FOR JOIST BEANING ON BEAM LEDGER TO WALL RAILING TO WALL RAILING TO BEAM,RAILING TO COLUMN, BEAM TO COLUMN AND STRINGER TO HEADER (4) COLUMN HAVE SERVE SPLITER THAT RUN THE ENTIRE LENGTHS AND SPLDLE CONNECTIONS WITH 12 INCH LAPS AND 2 BOLTS (5) COLUMNS OVERNOTCHED AT FLOOR DECKS AND INTERMEDIATE LOADINGS (6) MASONRY BEAM POCKETS MISSING HARDWARE CONNECTIONS TO BEAM (7) PLANS AND PERMIT REQUIRED | 936 W 76TH ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | WALLS BULGING WASHOUT MORTAR,REQUIRE PERMIT,SOUTH AND EAST | 936 W 76TH ST | COMPLAINT | PASSED | View |
PARAPET | WALLS BULGING WASOUT MORTAR REQUIRE PERMIT | 936 W 76TH ST | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | CHIMNEY MISSING CAP | 936 W 76TH ST | COMPLAINT | PASSED | View |
REPAIR LINTELS | LINTEL SAGGING WASHOUT MORTAR REQUIRE PERMIT | 936 W 76TH ST | COMPLAINT | PASSED | View |
DWELLING CLEAN AND SANITARY | MILDREW AND MOLDED THRU-OUT | 936 W 76TH ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | APT1 AND STAIRWAY NO SMOKE DETECTOR | 936 W 76TH ST | COMPLAINT | PASSED | View |
STOP LEAKING WATER | LEAKAGE AROUND WINDOWS | 936 W 76TH ST | COMPLAINT | PASSED | View |
UNAPPROVED HEATING DEVICE | TENANTS USING STOVE FOR HEAT, APT. 944, 2ND FLOOR, AND 942, 2ND FLOOR | 936 W 76TH ST | COMPLAINT | FAILED | View |