Chicago Building Violations Data: 12 Violations
Violation Inspector Comments Address Category Status View
SUPPLY HOT WTR MIN TEMP 120DEG GAS SERVICE SHUT OFF NO HOT WATER PROVIDED. 6819 S HARPER AVE COMPLAINT FAILED View
PARAPET SOUTH ELEVATION ... THE PARGE COAT IS FRACTURED. 6819 S HARPER AVE COMPLAINT FAILED View
DWELLING CLEAN AND SANITARY BASEMENT WALLS ... EXCESSIVE MOLD ... ALL ROOMS. 6819 S HARPER AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION BASEMENT SEEPAGE ISSUES ... FRACTURED CONCRETE FOUNDATION WALLS. 6819 S HARPER AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FIRST FLOOR ... NO SMOKE DETECTORS. 6819 S HARPER AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID FIRST FLOOR ... NO CARBON MONOXIDE DETECTOR. 6819 S HARPER AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE FIRST FLOOR BATHROOM ... DAMAGED VENT AT GLASS BLOCK WINDOW. 6819 S HARPER AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR REAR STORM DOOR ... FIRST FLOOR ... MISSING BOTTOM DOOR SWEEP. THE DOOR DOESN'T CLOSE FLUSH IN FRAME. THE SAME CONDITION EXISTS AT THE MAIN REAR DOOR ... SAME DOORWAY OIPENING. 6819 S HARPER AVE COMPLAINT FAILED View
REPLACE D&H PORCH TWO STORY REAR PORCH ... NO STRUCTURAL FOOTINGS. NO BOLTS AT RIM BEAMS. NO MECHANICAL FASTENERS AT BANISTER TO POST CONNECTION. NO STAIR STRINGER HANGERS. INCORRECT LAP JOINT AT STACKED 6X6 COLUMS ... AT THE COLUMN TO BEAM JOINT THE CONNECTION HAS FAILED ... THE JOINTED MEMBERS ARE PULLING APART ... NO STRUCTURAL BRACKETS AT THESE JOINTS. THE RAILINGS ARE TOO LOW AT 32". THBIS PORC H IS IN DANGEROUS AND HAZARDOUS CONDITION AND BEYOND REPAIR ... TEAR DOWN AND REPLACE WITH NEW ... PLANS AND PERMIT REQUIRED. 6819 S HARPER AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY GAS SERVICE SHUT OFF NO HEAT PROVIDED. 6819 S HARPER AVE COMPLAINT FAILED View
INSECTS FIRST FLOOR ... BED BUG INFESTATION. 6819 S HARPER AVE COMPLAINT FAILED View
MICE/RODENTS FIRST FLOOR ... RODENT INFESTATION. 6819 S HARPER AVE COMPLAINT FAILED View