The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | WEST PORCH GUARDRAILS ARE 32"- MISSING END POST TO WALL AND PICKETS. | 5115 S MORGAN ST | COMPLAINT | PASSED | View |
WINDOW AREA ABOVE GROUND | BASEMENT BEDROOM AND KITCHEN WINDOWS ARE GLASS BLOCKS | 5115 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR EAVES | ROOF EAVES MISSING ALUMINUM CAP. | 5115 S MORGAN ST | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | 1ST FLOOR NO ENTRY TO VERIFY OCCUPANCY SMOKE AND CARBON MONOXIDE DETECTORS. | 5115 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT PORCH (1-STORY; 200 SQ.FT. LANDING)-EDGE BEAM IS SET ON TOP OF PIECES OF LUMBER SET ON TOP OF THE MASONRY COLUMNS; NO VISIBLE CONNECTORS. SISTERED 2X6 MEMBERS UTILIZED AS A CENTER BEAM. DECK JOISTS ARE SET GREATER THAN 16 INCHES APART; JOISTS ARE ONLY TOE NAILED INTO THE EDGE BEAM AND CENTER BEAM CONNECTIONS. STRINGERS ARE WORN AND ONLY NAILED INTO THE DECK JOIST AND WOOD BRIDGING CONNECTIONS. OBTAIN PERMIT FOR PORCH REPAIRS. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | EXTERIOR DOOR OPENING-ONLY 5 FEET 8 INCH HEIGHT. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
BASEMENT, DISCONTINUE | BASEMENT - UTILIZED AS A HABITABLE DWELLING UNIT. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT FOR THE REMOVAL OF THE PARTITIONS AND FIXTURES (INCLUDING PLUMBING; ELECTRIC; VENTILATION), INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR-NOT AFFIXED TO THE WALL OR CEILING; RESTED ON TOP OF THE MICROWAVE OVEN. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTOR-MISSING. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTOR-MISSING. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | ACCUMULATION OF PERSONAL ITEMS, JUNK AND APPLIANCES UNDERNEATH THE STAIRS AND ON THE LANDING (UNVERIFED CONDITION OF PORCH STRUCTURAL COMPONENTS). | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
MICE/RODENTS | MICE DROPPINGS. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | FLOOR-HOLES IN SUBFLOOR; BROKEN AND MISSING TILES. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | DEAD BOLT LOCK-MISSING. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED DETECTORS. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT BASEMENT DOOR - RUSTED. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS - MISSING WINDOW SCREENS. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ONE STORY 200 SQ.FT. PORCH: LEDGER BOARD FASTENED TO EXTERIOR WALL WITH NSILS ONLY; EDGE BEAM IS SET ON TOP OF PICES OF LUMBER SET ON TOP OF MASONRY COLUMNS; NO VISIBLE CONNECTORS. SISTERED 2X6" MEMBERS UTILIZED AS A CENTER BEAM; DECK JOISTS ARE UP TO 21-1/2" APART; UNDERSIZED 2"X6" DECK JOISTS SPAN 9'-7" AND ARE ONLY TOENAILED INTO THE EDGE BEAM AND CENTER BEAM. STRINGERS ARE WORN AND ONLY NAILED INTO DECK JOISTS AND WOOD BRIDGING CONNECTIONS.REAR TWO STORY WOOD ENCLOSED PORCH.2X6" JOISTS ARE 24" APART AND ARE ONLY TOE NAILED TO CENTER SCABBED CENTER BEAM.GUARDRAILS ARE ONLY 31-1/2" HIGH GUARD AND HANDRAILS ARE OF LADDER TYPE DESIGN WITH HORIZONTAL TIES 10" APART.PERMIT ONLY REQUIRED TO REPAIR FRONT AND REAR PORCHES. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT NO ENTRY TO VERIFY OCCUPANCY, DETECTORS AND PREVIOUS VIOLATIONS, SEE INSPECTION # 10987825 OF INSPECTION DATE 08/01/14. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL WORK PERFORMED IN BASEMENT WITHOUT PERMITS | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL WORK PERFORMED IN BASEMENT INCLUDING PARTITION WALLS,KITCHEN AND BATH INSTALLATION,PLUMBING AND ELECTRICAL. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
PARTITIONS,N/L/B | BASEMENT APT -PANELING | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | BASEMENT FLOOR ROTTED AND AND OUT OF LEVEL | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | ONE STORY FRONT PORCH- 2X6 JOISTS OVERSPANNED.2X6 BEAMS OVERSPANNED.STRINGERS UNDERSIZED AND IMPROPERLY DESIGNED.ENCLOSED REAR PORCH-JOISTS OVERSPANNED.STRINGERS IMPROPERLY DESIGNED.RAIL SECTIONS WITH HORIZONTAL COMPONENTS LEAVING LARGE GAPS.SUBMIT PLANS AND OBTAIN PERMITS FOR REPAIRS | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | COOKING DEVICE-BUILD UP OF GREASE ON AND ADJACENT THE STOVE. | 5115 S MORGAN ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | SOUTH MISSING GUTTER AND DOWNSPOUT | 5115 S MORGAN ST | COMPLAINT | PASSED | View |